Sign In
The Amprobe HD110C Heavy Duty Multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. Its made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts.
Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet. The HD110C has an extended voltage measurement capability of 1500 V DC and 1000 V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV.
FEATURES
Highest voltage capability, measuring to 1500 Vdc and 1000 Vac.
CAT IV 1000 V rated.
Special sealing for environment and water resistance. IP67 rated.
Constructed with drop-resistant housing and PCB mounting.
Measures capacitance, temperature and frequency.
Superior 10,000 count resolution with bar graph.
Magne-Grip™ holster, frees both hands for workIncludes high voltage test leads with threaded alligator clips.
Temperature measurement built-in.
Frequency and capacitance.
Digi-Glo™ bright backlight.
Amprobe HD110C Heavy-Duty Digital Multimeter Specifications
General Specifications
Display
3-1/2 digit LCD, 1999 counts, with annunciators and menu features.
Polarity Indication
Automatic.
Input Overload Indication
1.
Low Battery Indication
Symbol at less than 50 hours battery life remaining (accuracy no longer guaranteed).
Display Update Rate
2.5/sec nominal.
Operating Temperature
0 to +50°C @ 0 to 75% RH.
Storage Temperature
-20 to 60°C @ 0 to 80% RH, battery removed.
Temperature Coefficient
0.1 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) all functions and ranges except for mVDC
0.3 x (spec. accuracy)/°C (0 ° to 18 °C and 28° to 50 °C) for mVDC.
Fuse
F 2A/1500V fuse (8mm x 65mm), I.R. 30kA - Amprobe p/n FP700.
Power
Standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22.
Auto Power Down
Meter powers down after approximately 30 minutes of inactivity.
Battery Life (typical)
250 hours typical with carbon-zinc, 500 hours typical with alkaline.
Dimensions (without holster)
200 x 102 x 59mm (7.9 x 4.0 x 2.3") - H x W x D.
Weight (Incl. Battery)
642g (22oz).
Case material
Reinforced, high-impact, fire retardant thermoplastic.
Safety
Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67.
EMC
Meets EN 61326-1.
Electrical Specifications (Accuracy at 23 °C + 5 °C, Accuracy at 23 °C + 5 °C, <75 % RH, guaranteed for one year)
DC Voltage
Ranges
200mV, 2V, 20V, 200V, 1500V.
Resolution
0.1mV.
Accuracy
+(0.1% rdg + 5 digits).
Input Impedance
10MΩ.
OL Protection
1500V DC or 1000V AC RMS.
Transient Protection
12kV impulse (1.2µS/50µS) based on EN 61010-1:2001 impulse requirements for CAT IV 1000V/1500V DC products. This product should not be used in installations where transients exceed 12kV.
AC Voltage (True RMS)
Ranges
200mV, 2V, 20V, 200V, 1000V.
Resolution
0.1mV.
Accuracy
200 mV to 200 V (45-500 Hz) +(0.8 % rdg+4 dgts)
200 mV to 200 V (500 Hz-2 kHz) +(1.5 % rdg+5 dgts)
1000 V (50-60 Hz) +(0.8 % rdg+4 dgts)
1000 V (60-500 Hz) +(1.5 % rdg+5 dgts). Input Impedance 10MΩ. OL Protection 1500V DC or 1000V AC RMS. Transient Protection 12kV impulse (1.2µS/50µS) based on EN61010-1:2001 impulse requirement for CAT IV 1000V products. This product should not be used in installations where transients exceed 12kV. DC Current Ranges 200 µA, 2 mA, 20 mA, 200 mA, 2A. Resolution 0.1µA. Accuracy 200 µA to 20 mA +(0.5 % rdg+2 dgts) 200 mA to 2 A +(1.0 % rdg+2 dgts) OL Protection 1500 V dc/1000 V ac rms. AC Current (True RMS) Ranges 200 µA, 2 mA, 20 mA, 200 mA, 2A. Resolution 0.1µA. Accuracy (45 to 1kHz) 200 µA to 20 mA +(0.8 % rdg+4 dgts) 200 mA to 2 A +(1.2 % rdg+4 dgts) OL Protection 1500 V dc/1000 V ac rms . Resistance Ranges 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ. Resolution 0.1Ω. Accuracy 200 Ω +(0.5 % rdg+4 dgts) 2 kΩ to 200 kΩ +(0.3 %rdg+2 dgts) 2 MΩ +(1.0 % rdg+4 dgts) 20 MΩ +(2.0 %rdg+4 dgts) Overload Protection (All Ranges) 1500V DC or 1000V AC RMS. Diode/Continuity Test current 1m A dc typical. Test/Open Circuit Voltage 3.0 V dc typical. DiodeAccuracy +(1.5 % rdg+2 dgts). Continuity Audible Threshold <50 Ω+ 25 Ω. Response Time <100 msec. OL Protection 1500 V dc/1000 V ac rms.
200 mV to 200 V (500 Hz-2 kHz) +(1.5 % rdg+5 dgts)
1000 V (50-60 Hz) +(0.8 % rdg+4 dgts)
1000 V (60-500 Hz) +(1.5 % rdg+5 dgts). Input Impedance 10MΩ. OL Protection 1500V DC or 1000V AC RMS. Transient Protection 12kV impulse (1.2µS/50µS) based on EN61010-1:2001 impulse requirement for CAT IV 1000V products. This product should not be used in installations where transients exceed 12kV. DC Current Ranges 200 µA, 2 mA, 20 mA, 200 mA, 2A. Resolution 0.1µA. Accuracy 200 µA to 20 mA +(0.5 % rdg+2 dgts) 200 mA to 2 A +(1.0 % rdg+2 dgts) OL Protection 1500 V dc/1000 V ac rms. AC Current (True RMS) Ranges 200 µA, 2 mA, 20 mA, 200 mA, 2A. Resolution 0.1µA. Accuracy (45 to 1kHz) 200 µA to 20 mA +(0.8 % rdg+4 dgts) 200 mA to 2 A +(1.2 % rdg+4 dgts) OL Protection 1500 V dc/1000 V ac rms . Resistance Ranges 200Ω, 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ. Resolution 0.1Ω. Accuracy 200 Ω +(0.5 % rdg+4 dgts) 2 kΩ to 200 kΩ +(0.3 %rdg+2 dgts) 2 MΩ +(1.0 % rdg+4 dgts) 20 MΩ +(2.0 %rdg+4 dgts) Overload Protection (All Ranges) 1500V DC or 1000V AC RMS. Diode/Continuity Test current 1m A dc typical. Test/Open Circuit Voltage 3.0 V dc typical. DiodeAccuracy +(1.5 % rdg+2 dgts). Continuity Audible Threshold <50 Ω+ 25 Ω. Response Time <100 msec. OL Protection 1500 V dc/1000 V ac rms.
For more information on Amprobe HD110C Heavy-Duty Digital Multimeter talk to Cuthbertson Laird Group