Sign In
The Amprobe HD160C digital multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. The meter is made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts. Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistance to at least eight feet.
The HD160C is a heavy-duty 4-digit, autoranging, AC-coupled True RMS measuring instrument that measures voltage, current, resistance, continuity, as well as capacitance, frequency and temperature. It also offers Range Lock, Data Hold, Relative Measurement, Auto Min Max Measurement, a bright backlight, and Auto Power Off to save battery life. The instrument is completely o-ring sealed to pass strict IP-67 ratings for moisture and dust proof. The HD160C meets the highest safety rating of CAT IV 1000 V (1500V DC max).
FEATURES
Highest voltage capability, measuring to 1500 Vdc and 1000 Vac.
CAT IV 1000 V rated.
Special sealing for environment and water resistance. IP67 rated.
Constructed with drop-resistant housing and PCB mounting.
Measures capacitance, temperature and frequency.
Superior 10,000 count resolution with bar graph.
Magne-Grip™ holster, frees both hands for workIncludes high voltage test leads with threaded alligator clips.
Temperature measurement built-in.
Frequency and capacitance.
Digi-Glo™ bright backlight.
Amprobe HD160C Heavy-Duty Digital Multimeter Video
Amprobe HD160C Heavy-Duty Digital Multimeter Specifications
General Specifications
Display
4 digit LCD, 9999 counts, with annunciators, menu features and 41 segment bargraph.
Polarity Indication
Automatic.
Input Overload Indication
OL, -OL.
Low Battery Indication
Symbol at less than 50 hours battery life remaining (accuracy no longer guaranteed)
Display Update Rate
2/sec nominal; 20/sec for bargraph
Operating Temperature
0 to +50°C @ 0 to 75% RH.
Storage Temperature
-20 to 60°C @ 0 to 80% RH, battery removed.
Temperature Coefficient
0.1 x (spec. accuracy)/°C (0 to 18°C and 28 to 50°C).
Fuse
F 2A/1500V fuse (8mm x 65mm), I.R. 30kA - Amprobe p/n FP700.
Power
Standard 9V battery, NEDA 1604, JIS 006P, IEC 6F22.
Auto Power Down
Meter powers down after approximately 30 minutes of inactivity. Not in MIN/MAX function.
Battery Life (typical)
150 hours, alkaline. Backlight usage consumes extra power and will decreased battery life significantly. Backlight auto off after approx 60 seconds.
Dimensions (without holster)
200 x 102 x 59mm (7.9 x 4.0 x 2.3") - H x W x D.
Weight (Incl. Battery)
642g (22oz).
Case material
Reinforced, high-impact, fire retardant thermoplastic.
Safety
Meets EN 61010-1 CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67CAT IV 1000 V (1500 V DC max) Class II, EN 60529:IP67.
EMC
Meets EN 61326-1.
Electrical Specifications (Accuracy at 23 °C + 5 °C, Accuracy at 23 °C + 5 °C, <75 % RH, guaranteed for one year)
DC Voltage
Ranges
1000mV, 10V, 100V, 1500V.
Resolution
0.1mV in 1000mV range.
Accuracy
+(0.1% rdg + 5 digits).
Input Impedance
10MΩ.
CMRR
>120dB up to 1500V DC.
NMRR
>60dB at 50/60Hz.
OL Protection
1500V DC or 1000V AC RMS.
Transient Protection
12kV impulse (1.2µS/50µS) based on EN 61010-1:2001 impulse requirements for CAT IV 1000V/1500V DC products. This product should not be used in installations where transients exceed 12kV.
AC Voltage (True RMS)
Ranges
1000mV, 10V, 100V, 1000V.
Resolution
0.1V in 1000mV range.
Accuracy
1000mV (45 to 400Hz): +(1.2% rdg + 10 digits)
10V, 100V (45 to 500Hz): +(1.2% rdg + 10 digits)
10V, 100V (500Hz to 2kHz): +(2.0% rdg + 10 digits)
1000V (45 to 1kHz): +(2.0% rdg + 10 digits)
Input Impedance
10MΩ.
Conversion Type
True RMS, AC coupled 5% to 100% of range.
Crest Factor
?3
OL Protection
1500V DC or 1000V AC RMS.
Transient Protection
12kV impulse (1.2µS/50µS) based on EN61010-1:2001 impulse requirement for CAT IV 1000V products. This product should not be used in installations where transients exceed 12kV.
DC Current
Ranges
100µA, 1000µA, 10mA, 100mA, 400mA, 2A (auto/manual ranging).
Resolution
0.01µA in 100µA range.
Accuracy
100µA range: +(0.5% rdg + 10 digits)
1000µA to 400mA ranges: +(0.5% rdg + 5 digits)
2A range: +(1.5% rdg + 10 digits).
Input Protection
2A/1500V fast blow ceramic fuse 8 x 65mm on A input, FP700.
Burden Voltage
µA range of 1mV/1µA, mA range of 10mV/1mA, 2A range of 500mV/1A, 500mV max. (2V max on 1000µA, 100mA, 400mA, 2A ranges).
OL Protection
A input (F 2A/1500V, size 8 x 65mm IR fast blow ceramic).
AC Current (True RMS)
Ranges
100µA, 1000µA, 10mA, 100mA, 400mA, 2A.
Resolution
0.01µA in 100µA range.
Accuracy (45 to 1kHz)
100µA to 100mA: +(1.5% + 10 digits)
400mA: +(2.0% + 10 digits)
2A: +(2.5% + 20 digits).
Voltage Burden
See DC current.
Conversion Type
True RMS AC couple 10 to 100% of range.
Crest Factor
?3.
OL Protection
See DC current.
Resistance
Ranges
1000Ω, 10kΩ, 100kΩ, 1000kΩ, 10MΩ, 40MΩ.
Resolution
0.1Ω in 1000Ω range.
Accuracy
1000Ω to 1000kΩ: +(0.5% rdg + 8 digits)
10MΩ: +(1.0% rdg + 10 digits)
40MΩ: +(2.0% rdg + 10 digits).
Overload Protection (All Ranges)
1500V DC or 1000V AC RMS.
Continuity
Audible Indication
Less than 40Ω.
Response Time
100ms.
Overload Protection
1500V DC or 1000V AC RMS.
Capacitance
Ranges
40nF, 400nF, 4µF, 40µF, 400µF (3999 counts) - auto/manual ranging.
Resolution
0.01nF.
Accuracy
40nF, 400µF: +(3.0% rdg + 10 digits)
400nF to 40µF: +(3.0% rdg + 5 digits).
Test Voltage
<1V.
Test Frequency
1.3Hz on 40nF to 40µF ranges; 0.7Hz on 400µF range.
Overload Protection
1500V DC or 1000V AC RMS.
Temperature
Ranges
-20 to 1300°C (-4 to 2372°F).
Resolution
1°C, 1°F).
Accuracy
-20 to 10°C: +(2.0% rdg + 4°C)
10 to 200°C: +(1.0% rdg + 3°C)
200 to 1300°C: +(2.0% rdg + 2°C).
Frequency
Ranges
100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz.
Resolution
0.01Hz on 100Hz range.
Accuracy
+(0.1% rdg + 5 digits).
Sensitivity
3Hz to 1mHz: >2.5V AC RMS
1mHZ to 10mHZ: >2.5V AC RMS, <5V AC RMS.
Minimum Input Range
100Hz range: >3Hz
1000Hz range: >30Hz.
Minimum Pulse Width
>25ns.
Duty Cycle Limits
>30% and <70%.
Overload Protection
1500V DC or 1000V AC RMS .
For more information on Amprobe HD160C Heavy-Duty Digital Multimeter talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.