Sign In
Rugged and waterproof, the Chauvin Arnoux CA 6424 earth tester can be used for 2P and 3P earth measurements in total safety. Text markings and colour coding help users to avoid connection errors. It can also measure the voltage up to 600 V. All the measurements and functions are directly accessible on the front panel, even when wearing gloves.
Special connection technology for the G72 clamp allows measurement of the line (phase) current and leakage current, from 0.5 mA to 60 A. There is a dedicated key for cable compensation. A LED indicates when a hazardous voltage is present, while the NOISE symbol flashes to indicate when a noise voltage is present.
Equipped with a 3-display backlit screen, the CA 6424 ohmmeter lets you view all the useful information on a single screen: measurement result, errors concerning the measurements or the recorded values, as well as complementary information (USE, HR, etc.).
Designed with safety in mind, the moment a hazardous voltage is detected, an LED lights up and measurement is prohibited. The connections have text marking and colour coding to help prevent mistakes as an added safety feature.
FEATURES
2P resistance / 3P earth measurements up to 50 kΩ in high-resistivity terrain.
Voltage measurement up to 600 V and RH stake resistance measurement.
Automatic stabilization of the measurement.
Help with positioning the stakes - average and 52%/62%/72% deviation.
Leakage current measurement from 0.5 mA.
Battery recharging via the mains, USB socket or vehicle cigarette lighter.
CA 6422 & CA 6424 Comparison Chart
Instrument Functions
C.A 6422
C.A 6424
Earth resistance measurement (with three rods)
Voltage measurement
Resistance measurement
Mean of the earth measurements at 52, 62 and 72%
Detection of RH too high
Detection of RE too high
Detection of a spurious voltage on USE
Measurement of AC current with an ammeter clamp (optional)
Chauvin Arnoux CA6424 Specifications
Voltage
Range
0.1-600 V.
Resolution
0.1 V.
Accuracy
+ (1%R + 1 ct).
2P Resistance
Range
0.05 - 99.99 Ω / 80.0 - 999.9 Ω / 0.800 - 9.999 kΩ / 8.00 - 50.00 kΩ.
Resolution
0.01 Ω / 1 Ω / 10 Ω / 100 Ω.
Accuracy
+ (2%R + 10 cts) / + (2%R + 2 cts) / +(2%R + 1 ct) / + (2%R + 1 ct).
Cable compensation
up to 5 Ω.
3P Earth Resistance
Range
0.5 Ω - 50.00 kΩ.
Resolution
0.01 Ω / 0.1 Ω / 1 Ω / 10 Ω.
Accuracy
+(1%R + 10 cts) / +(1%R +2 cts) / +(1%R + 1 ct).
Measurement frequency
128 Hz or 256 Hz.
No-load voltage
+10 V peak.
Measurement mode
One-shot or permanent.
Data storage
Registers: RE @ 62%; RE @ 52%; RE @ 72%.
Calculation of average
Calculation of the average and the % deviation in relation to the average.
RH Stake Resistance Measurement
Range
0.05-9.999 kΩ / 8 - 49.99 kΩ.
Resolution
1 Ω / 10 Ω.
Accuracy
+(10%R + 1 ct).
USE Voltage Measurement
Range
0.10 - 99.99 VAC / 80.0 - 600 VAC.
Resolution
0.01 V / 0.1 V.
Accuracy
+(2%R + 2 cts).
Current Measurement (via optional G72 clamp)
Range
0.5 - 999.9 mA / 0.800-9.999 A / 8.00-60.00 A.
Resolution
0.1 / 1 / 10 mA.
Accuracy
+(1%R + 4 cts) / +(1%R + 2 cts).
General Specifications
Display
Backlit custom 206-segment LCD.
Measurement mode
V, I, R 2P (Ω), R 3P (Ω).
Power supply
6 x NiMH rechargeable batteries, charging time approx.. 6 hrs.
Charger
Internal via mains/USB adapter supplied.
Automatic power-off
Deactivatable.
Battery life
>1,500 x 3P earth measurements at 100 Ω.
Dimensions
223 x 126 x 70 mm.
Weight
1 kg.
Environment
Operation: -10 to +50°C / Storage: -40 to +70°C (without batteries/accumulators).
Protection
Up to 600 V on any of the input terminals.
IP/IK index
IP 65 as per IEC 60529 / IK 04 as per IEC 50102.
Drop test
1 metre as per IEC 61010-1.
Standards / electrical safety
EMC: IEC 61326-1; IEC 61010-2-030 / 600 V CAT IV.
Compliance with IEC 61557
IEC 61557-1 and IEC 61557-5.
Chauvin Arnoux C.A 6424 warranty
24-months.
For more information on Chauvin Arnoux CA6424 Earth Tester talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.