The Chauvin Arnoux C.A 6550 megohmmeter is a high-end portable measuring instruments intended for the measurement of very high electrical insulation and resistance values, mounted in a rugged site housing with a cover; it has a graphic screen and can operate on battery or mains power.
With its site-proof casing, the Chauvin C.A 6550 insulation tester is used to check equipment insulation during manufacturing, on-site installation work, periodic inspections and recommissioning of installations.
Specially adapted for checking insulation on rotating machinery with a 12 kV power supply or higher, the Chauvin C.A6550 complies with the IEEE43 standard which recommends insulation testing at 5-10kV.
FEATURES
Wide measurement range from 10 kΩ to 30 TΩ.
Fixed or programmable test voltage from 40 V to 10/15 kV.
5 mA charging current.
Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs.
Automatic calculation of DAR / PI / DD /?R (ppm/V) ratios.
Multiple test modes: voltage ramp and step with “burning”, “early break” and “I-limit” modes.
3 filters to optimise measurement stability.
Calculation of R at a reference temperature.
Storage of 80,000 measurements and Real-time Clock.
Optically-isolated USB communication for transfer onto PC and report generation with the DataView® software.
Chauvin CA6550 & CA6555 Specifications
CA6550
CA6555
Test Voltages
10kV
15kV
Test Voltages
Ranges
500 V: 10 kΩ to 2 TΩ
1000 V: 10 kΩ to 4 TΩ
2500 V: 10 kΩ to 10 TΩ
5000 V: 10 kΩ to 15 TΩ
500 V: 10 kΩ to 25 TΩ
15000 V: 10 kΩ to 30 TΩ.
Fixed Test Voltages
500 / 1,000 / 2,500 / 5,000 / 10,000 V
500 / 1,000 / 2,500 / 5,000 / 10,000 / 15,000 V
Variable Test Voltages
40 V - 10,000 V
3 Settable Voltage Values
40 V - 15,000 V
3 Settable Voltage Values.
Adjustment Increment
for Variable Voltages
Variable: 40-10 kV step : 40 V-1 kV: 10 V
1 kV-10 kV: 100 V
Variable: 40-15 kV step: 40 V-1 kV: 10 V
1 kV-15 kV: 100 V.
Ramp Mode
3 presettable ramps: start voltage / end voltage / duration.
Ramp Configuration Mode
40-1,100 V / 500-10,000 V
40-1,100 V / 500-15,000 V
Step Mode
Up to 10 steps (value and duration con gurable for each step).
Voltage Measurement After Test
AC: 0 - 2,500 V / DC: 0 - 4,000 V.
Capacitance Measurement
0.001-9.999 µF / 10.00-49.99 µF.
Leakage Current Measurement
0 - 8 mA.
Discharge After Test
Yes/Automatic.
Additional Test Stop Modes
I-limit
Programmable: 0.2-5 mA.
Early Break
di/dt.
Timer
Up to 99 minutes 59 seconds.
Burning Mode
Burning
Constant Testing.
Ratio Calculation
PI, DAR, DD.
Calulcation of R at ref. T°
Yes.
Measurement Display Filter
3 Filters with 3 Possible Time Constant.
Graphs on Display
R(t)+u(t); i(t); i(u);
Storage
256 recordings, 80,000 points : R, U, I and date.
Communication
Optically-isolated port for USB and RS232 links.
PC Software
DataView
Power Supply
NiMH rechargeable batteries, 8x 1.2 V / 4,000 mAh
charging by external voltage: 90-260 V 50/60 Hz.
Battery Charging
Battery charging possible while performing insulation measurements.
Electrical Safety
1,000 V CAT IV - IEC 61010-1 and IEC 61557.
EMC, Mechanical Protection, Altitude
EN 61326-1 , IP54 , 3,000 m.
Dimensions
LxWxH: 340 x 300 x 200 mm.
Weight
6.2 kg approx. (excluding accessories).
Chauvin CA6550 warranty
One year.
For more information on Chauvin C.A 6550 10KV Insulation Tester talk to Cuthbertson Laird Group