Sign In
The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems.
The Fluke 113 has significant improvements over other digital multimeters available on the market. Using the Fluke VCHEK LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox.
FEATURES
VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity.
True RMS for accurate AC measurements on non-linear loads.
A large backlit display allows for easy visibility in low-lit areas.
Record signal fluctuations using the Min/Max function.
Diode test for testing general-purpose germanium, silicon, and power diodes.
Integral holster with probe holders for easy storage.
Auto and Manual ranging for added user functionality.
Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety.
Fluke 113 Specifications
VCHEK1 2 3
Range
6 V
60 V
600 V
Resolution
0.001 V
0.01 V
0.1 V
Accuracy
DC, 45 to 500 Hz: 2.0% + 3
500 Hz to 1 kHz: 4.0% + 3
Diode Test4
Range
2 V.
Resolution
0.001 V.
Accuracy
2.0% + 3.
Continuity4
Accuracy
Beeper on <20Ω, off >250Ω; detects opens or shorts of 500µs or longer.
Resistance4
Range
6 Ω
6 kΩ
60 kΩ
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
Accuracy
0.9% + 2
0.9% + 1
0.9% + 1
Capacitance4
Range
1000 nF
10 µF
100 µF
9999 µF
Resolution
1 nF
0.01 µF
0.1 µF
1 µF
Accuracy
1.9% + 2
1.9% + 2
1.9% + 2
100 µF - 1000 µF: 1.9% + 2
>1000 µF: 5% + 20
1. All VChek voltage ranges are specified from 60 counts to 100% of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together.
2. Crest factor of ? 3 at 4000 counts, decreasing linearly to 1.5 at full scale.
3. Minimum measureable input in VCHEK autorange is 3 VDC. For measurements below 3 VDC, push Range button twice to get to 6 VDC manual range.
4. After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity.
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground
600 V
Display
3¾ digits, 6000 counts, updates 4/sec.
Operating Temperature
-10 to 50°C (14 to 122°F).
Storage Temperature
-40 to 60°C (-22°F to 140°F).
Temperature Coefficient
0.1 x (specified accuracy)/°C (<18°C or >28°C).
Operating Altitude
2000m.
Storage Altitude
10000m.
Relative Humidity
95% to 30°C
75% to 40°C
45% to 50°C
Battery Type
9V alkaline, ANSI 1604A / IEC 6F22.
Battery Life
Alkaline: 300 hours typical, without backlight.
Shock
1m drop per IEC 61010-1-2001.
Vibration
Per MIL-PRF-28800 for class 2 instrument.
Dimensions (H x W x L)
167.1mm x 85.1mm x 46.0mm (6.58in x 3.35in x 1.81in).
Weight
13.0oz (404g).
Safety
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd edition for measurement category IV, 600V, pollution degree 2, EMC EN61326-1.
Fluke 113 warranty
3 years.
For more information on Fluke 113 True RMS Multimeter talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.