Sign In
The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. This true-rms meter provides easy one-handed operation in a compact package.
The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap.
FEATURES
Resistance, continuity, frequency, capacitance, and diode test.
Measures 10 A (20 A overload for 30 seconds).
Large white LED backlight to work in poorly lit areas.
Compact ergonomic design for one-handed operation.
Compatible with optional magnetic hanger (ToolPak™).
True-rms for accurate measurements on non- linear loads.
Min/Max/Average with elapsed time to record signal fluctuations.
CAT III 600 V safety rated.
Fluke 115 Specifications
Maximum voltage between any terminal and earth ground
600 V.
Surge protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2.
Display
Digital - 6,000 counts, updates 4 per second.
Bar graph
33 segments, updates 32 per second.
Operating Temperature
-10 °C to + 50 °C.
Storage Temperature
-40 °C to + 60 °C.
Battery type
9 volt Alkaline, NEDA 1604A/ IEC 6LR61.
Battery Life
400 hours typical, without backlight.
DC millivolts
Range: 600.0 mV.
Resolution: 0.1 mV.
Accuracy: + ([% of reading] + [counts]): 0.5% + 2.
DC Volts
Range/Resolution: 6.000 V / 0.001.
Range/Resolution: 60.00 V / 0.01 V.
Range/Resolution: 600.00 V / 0.1 V.
Accuracy: + ([% of reading] + [counts]): 0.5% + 2.
AC millivolts¹ true-rms
Range: 600.0 mV.
Resolution: 0.1 mV.
Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz).
AC volts¹ true-rms
Range/Resolution: 6.000 V / 0.001 V.
Range/Resolution: 60.00 V / 0.01 V.
Range/Resolution: 600.0 V / 0.1 V.
Accuracy:1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz).
Continuity
Range: 600 Ω.
Resolution: 1 Ω.
Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 µs or longer.
Ohms
Range/Resolution: 600.0 Ω / 0.1 Ω.
Range/Resolution: 6.000 kΩ / 0.001 kΩ.
Range/Resolution: 60.00 kΩ / 0.01 kΩ.
Range/Resolution: 600.0 kΩ / 0.1 kΩ.
Range/Resolution: 6.000 MΩ / 0.001 MΩ.
Accuracy: 0.9 % + 1.
Range/Resolution: 40.00 MΩ / 0.01 MΩ.
Accuracy: 5 % + 2.
Diode Test
Range/Resolution: 2.00 V / 0.001 V
Accuracy: 0.9% + 2.
Capacitance
Range/Resolution: 1000 nF / 1 nF
Range/Resolution: 10.00 µF / 0.01 µF
Range/Resolution: 100.0 µF / 0.1 µF
Range/Resolution: 9999 µF / 1 µF
Range/Resolution: 100 µF to 1000 µF
Accuracy: 1.9% + 2
Range/Resolution: > 1000 µF
Accuracy: 5% + 20%.
Lo-Z Capacitance
Range: 1 nF to 500 µF
Accuracy: 10% + 2 typical.
AC amps true-rms (45 Hz to 500Hz)
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.5% + 3
20 A overload for 30- seconds max.
DC amps
Range/Resolution: 6.000 A / 0.001 A
Range/Resolution: 10.00 A / 0.01 A
Accuracy: 1.0% + 3
20 A overload for 30- seconds max.
Hz (V or A input)2
Range/Resolution: 99.99 Hz / 0.01 Hz
Range/Resolution: 999.9 Hz / 0.01 Hz
Range/Resolution: 9.999 kHz / 0.001 kHz
Range/Resolution: 50 kHz / 0.01 kHz
Accuracy: 0.1% + 2.
Dimensions
167 x 84 x 46 mm (6.57" x 3.31" x 1.82").
Weight
550 g.
Fluke 115 warranty
3 years.
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F.
For more information on Fluke 115 True RMS Multimeter talk to Cuthbertson Laird Group