Find The Needle Add My Company
Fluke 116 HVAC Multimeter
The Fluke 116 digital multimeter delivers the capabilities professionals demand to troubleshoot and repair HVAC (heating, ventilation and air conditioning) systems. It has everything you need in an HVAC meter, including temperature and microamp measurements to help you quickly troubleshoot problems with HVAC equipment and flame sensors. FEATURES Built-in thermometer for HVAC applications. Microamps to test flame sensors. Low input impedance: helps prevent false readings due to ghost voltage. Large white LED backlight to work in poorly lit areas. Resistance, continuity, frequency and capacitance. Min/Max/Average with elapsed time to record signal fluctuations. Compact ergonomic design for one-handed operation. Compatible with optional magnetic hanger (ToolPak™). CAT III 600 V safety rated. Using The Fluke 116 Digital Multimeter Fluke 116 Specifications Measurement Range Resolution Accuracy +(% of reading + counts) DC Millivolts 600.0 mV 0.1 mV 0.5% + 2. DC Voltage 6.000 V 0.001 V +([% of reading] + [counts]): 0.5% + 2. 60.00 V 0.01 V 600.0 V 0.1 V Autovoltage 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz). AC Millivolts (True RMS)¹ 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz). AC volts (True RMS)¹ 6.000 V 0.001 V 1.0% + 3 (45 to 500Hz) 2.0% + 3 (500Hz to 1kHz). 60.00 V 0.01 V 600.0 V 0.1 V Continuity 600 Ω 1 Ω Beeper on < 20 Ω Off > 250 Ω Detects opens or shots of 500 µs or longer. Resistance 600.0 Ω 0.1 Ω 0.9% + 1. 6.000 kΩ 0.001 kΩ 0.9% + 1. 60.00 kΩ 0.01 kΩ 600.0 kΩ 0.1 kΩ 6.000 MΩ 0.001 MΩ 40.00 MΩ 0.01 MΩ 5% + 2. Diode Test 2.000 V 0.001 V 0.9% + 2. Capacitance 1000 nF 1 nF 1.9% + 2. 10.00 µF 0.01 µF 100.0 µF 9,1 µF 9999 µF 1 µF - 100 µF to 1000 µF - 1.9% + 2. >1000 µF - 5% + 20. Lo-Z Capacitance 1 nF to 500 µF - 10.0 % + 2 typical. Temperature2 (Type-K thermocouple) -40°C to 400°C 0.1°C 1% + 102. -40 °F to 752°F 0.2°F 1% + 182. AC µA True RMS (45 Hz to 500 Hz) 600.0 µA 0.1 mV 1.5 % + 3. DC µA True RMS (45 Hz to 500 Hz) 600.0 µA 0.1 mV 1.0 % + 2. Frequency (V or A input)? 99.99 Hz 0.01 Hz 0.1% + 2 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 50.00 kHz 0.01 kHz 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. General Specifications Maximum Voltage Between Any Terminal and Earth Ground 600 V. Surge Protection 6 kV peak per IEC 61010-1 600V, CAT III, Pollution Degree 2. Fuse for A Input 11 A, 1000 V FAST fuse (Fluke PN 803292). Display Digital: 6000 counts, updates 4/sec. Bargraph 33 segments, updates 32/sec. Operating Temperature -10 to +50°C. Storage Temperature -40 to +60°C. Battery 9V alkaline, NEDA 1604A/IEC 6LR61. Battery Life 400 hours typical, without backlight. Dimensions 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in). Weight 550 g. Fluke 116 warranty 3 years.

For more information on Fluke 116 HVAC Multimeter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title