Find The Needle Add My Company
Fluke 117 Digital Multimeter
The advanced features of the Fluke 117 help you get the job done, quickly and safely. Integrated non-contact voltage detection helps you identify energized circuits. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 117 delivers true-rms ac voltage and current readings with 6000-count resolution. It provides Min/Max/Average readings and measures frequency and capacitance. The battery door is easy to access, so you and your Fluke 117 can stay on the job. FEATURES VoltAlert™ technology for non-contact voltage detection. AutoVolt automatic AC/DC voltage selection. Low input impedance: helps prevent false readings due to ghost voltage. Large white LED backlight to work in poorly lit areas. True RMS for accurate measurements on non-linear loads. Measures 10 A (20 A overload for 30-seconds). Resistance, continuity, frequency and capacitance. Min/Max/Average with elapsed time to record signal fluctuations. Compact ergonomic design for one-handed operation. Compatible with optional magnetic hanger (ToolPak™) for hands free operation. CAT III 600 V safety rated. Fluke 117 Specifications Measurement Range Resolution Accuracy +(% of reading + counts) DC Millivolts 600.0 mV 0.1 mV 2.0% + 3. DC Voltage 6.000 V 0.001 V +([% of reading] + [counts]): 0.5% + 2. 60.00 V 0.01 V 600.0 V 0.1 V Autovoltage 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz). AC Millivolts (True RMS)¹ 6.000 V 0.001 V 1.0% + 3 (45 to 500Hz) 2.0% + 3 (500Hz to 1kHz). 60.00 V 0.01 V 600.0 V 0.1 V Continuity 600 Ω 1 Ω Beeper on < 20 Ω Off > 250 Ω Detects opens or shots of 500 µs or longer. Resistance 600.0 Ω 0.1 Ω 0.9% + 2. 6.000 kΩ 0.001 kΩ 0.9% + 1. 60.00 kΩ 0.01 kΩ 600.0 kΩ 0.1 kΩ 6.000 MΩ 0.001 MΩ 40.00 MΩ 0.01 MΩ 1.5% + 2. Diode Test 2.000 V 0.001 V 0.9% + 2. Capacitance 1000 nF 1 nF 1.9% + 2. 10.00 µF 0.01 µF 100.0 µF 9,1 µF 9999 µF 1 µF - 100 µF to 1000 µF - 1.9% + 2. >1000 µF - 5% + 20. AC Current (True RMS) 45 to 500 Hz 6.000 A 0.001 A 1.0% + 3. 10.00 A 0.01 A 20 A continuous overload for 30 seconds max. DC Current 6.000 A 0.001 A 1.0% + 3. 10.00 A 0.01 A 20A continuous overload for 30 seconds max. Frequency (V or A input)? 99.99 Hz 0.01 Hz 0.1% + 2 999.9 Hz 0.1 Hz 9.999 kHz 0.001 kHz 50.00 kHz 0.01 kHz 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. General Specifications Maximum Voltage Between Any Terminal and Earth Ground 600 V. Surge Protection 6 kV peak per IEC 61010-1 600V, CAT III, Pollution Degree 2. Fuse for A Input 11 A, 1000 V FAST fuse (Fluke PN 803292). Display Digital: 6000 counts, updates 4/sec. Bargraph 33 segments, updates 32/sec. Operating Temperature -10 to +50°C. Storage Temperature -40 to +60°C. Battery 9V alkaline, NEDA 1604A/IEC 6LR61. Battery Life 400 hours typical, without backlight. Dimensions 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in). Weight 550 g. Fluke 117 warranty 3 years.

For more information on Fluke 117 Digital Multimeter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title