Sign In
The advanced features of the Fluke 117 help you get the job done, quickly and safely. Integrated non-contact voltage detection helps you identify energized circuits. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 117 delivers true-rms ac voltage and current readings with 6000-count resolution. It provides Min/Max/Average readings and measures frequency and capacitance. The battery door is easy to access, so you and your Fluke 117 can stay on the job.
FEATURES
VoltAlert™ technology for non-contact voltage detection.
AutoVolt automatic AC/DC voltage selection.
Low input impedance: helps prevent false readings due to ghost voltage.
Large white LED backlight to work in poorly lit areas.
True RMS for accurate measurements on non-linear loads.
Measures 10 A (20 A overload for 30-seconds).
Resistance, continuity, frequency and capacitance.
Min/Max/Average with elapsed time to record signal fluctuations.
Compact ergonomic design for one-handed operation.
Compatible with optional magnetic hanger (ToolPak™) for hands free operation.
CAT III 600 V safety rated.
Fluke 117 Specifications
Measurement
Range
Resolution
Accuracy +(% of reading + counts)
DC Millivolts
600.0 mV
0.1 mV
2.0% + 3.
DC Voltage
6.000 V
0.001 V
+([% of reading] + [counts]): 0.5% + 2.
60.00 V
0.01 V
600.0 V
0.1 V
Autovoltage
600.0 V
0.1 V
2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz).
AC Millivolts (True RMS)¹
6.000 V
0.001 V
1.0% + 3 (45 to 500Hz)
2.0% + 3 (500Hz to 1kHz).
60.00 V
0.01 V
600.0 V
0.1 V
Continuity
600 Ω
1 Ω
Beeper on < 20 Ω
Off > 250 Ω
Detects opens or shots of 500 µs or longer.
Resistance
600.0 Ω
0.1 Ω
0.9% + 2.
6.000 kΩ
0.001 kΩ
0.9% + 1.
60.00 kΩ
0.01 kΩ
600.0 kΩ
0.1 kΩ
6.000 MΩ
0.001 MΩ
40.00 MΩ
0.01 MΩ
1.5% + 2.
Diode Test
2.000 V
0.001 V
0.9% + 2.
Capacitance
1000 nF
1 nF
1.9% + 2.
10.00 µF
0.01 µF
100.0 µF
9,1 µF
9999 µF
1 µF
-
100 µF to 1000 µF
-
1.9% + 2.
>1000 µF
-
5% + 20.
AC Current (True RMS)
45 to 500 Hz
6.000 A
0.001 A
1.0% + 3.
10.00 A
0.01 A
20 A continuous overload for 30 seconds max.
DC Current
6.000 A
0.001 A
1.0% + 3.
10.00 A
0.01 A
20A continuous overload for 30 seconds max.
Frequency (V or A input)?
99.99 Hz
0.01 Hz
0.1% + 2
999.9 Hz
0.1 Hz
9.999 kHz
0.001 kHz
50.00 kHz
0.01 kHz
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground
600 V.
Surge Protection
6 kV peak per IEC 61010-1 600V, CAT III, Pollution Degree 2.
Fuse for A Input
11 A, 1000 V FAST fuse (Fluke PN 803292).
Display
Digital: 6000 counts, updates 4/sec.
Bargraph
33 segments, updates 32/sec.
Operating Temperature
-10 to +50°C.
Storage Temperature
-40 to +60°C.
Battery
9V alkaline, NEDA 1604A/IEC 6LR61.
Battery Life
400 hours typical, without backlight.
Dimensions
167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in).
Weight
550 g.
Fluke 117 warranty
3 years.
For more information on Fluke 117 Digital Multimeter talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.