Find The Needle Add My Company
Fluke 1507 Insulation Resistance Tester
For basic electrical insulation testing, choose the compact Fluke 1507 - a rugged, compact tool that handles the most common tests at a most affordable price. The remote test probe makes it easy to perform insulation and continuity tests in awkward area. FEATURES Automatic calculation of Polarization Index and Dielectric Absorption Ratio. Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function. Repetitive or hard-to-reach testing is easy with the remote test probe. Live circuit detection prevents insulation test if voltage > 30 V is detected. Auto-discharge of capacitive voltage for added user protection. Save battery power with auto power off. Read measurements easily with large, backlit display. CAT IV 600 V overvoltage category rating for added user protection. Accepts optional Fluke TPAK magnetic hanging system. Fluke 1507 Specifications AC/DC Voltage Measurement Range 600.0 V. Resolution 0.1 V. Accuracy + (2 % + 3). Input impedance 3 MΩ (nominal), < 100 pF. Common mode rejection ratio (1 kΩ unbalanced) > 60 dB at dc, 50 or 60 Hz. Overload Protection 600 V rms or dc. Earth Bond Resistance Measurement Range/Resolution 20.00 Ω - 0.01 Ω 200.0 Ω - 0.1 Ω 2000 Ω - 1.0 Ω 20.00 kΩ - 0.01 kΩ. Accuracy + (1.5 % + 3). Overload Protection 2 V rms or dc. Open Circuit Test Voltage > 4.0 V, < 8 V. Short circuit current > 200.0 mA. Insulation Specifications Measurement Range 0.01 MΩ to 10 GΩ. Test Voltage 50 V, 100 V, 250 V, 500 V, 1000 V. Test Voltage Accuracy + 20 %, - 0 %. Short circuit current 1 mA nominal. Auto Discharge Discharge time < 0.5 second for C = 1 µF or less. Live circuit indicator Inhibit test if terminal voltage > 30 V prior to initialisation of test. Maximum Capacitive Load Operable with up to 1 µF load. Measure Accuracy 50 V: +(3% + 5) 100 V: +(3% + 5) 250 V: +(1.5% + 5) 500 V: +(1.5 % + 5) 1000 V: +(1.5 % + 5) to 2000 MΩ, +(10 % + 3) above 2000 MΩ. General Specifications Maximum voltage applied to any terminal 600 V ac rms or dc. Storage Temperature -40 °C to 60 °C (-40 °F to 140 °F). Operating Temperature -20 °C to 55 °C (-4 °F to 131 °F). Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument. Shock 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor). Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV). Certifications CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition. Batteries Four AA batteries (NEDA 15A or IEC LR6). Battery Life 1000 insulation tests (with fresh alkaline batteries at room temperature), 2500 earth bond resistance measurements (with fresh alkaline batteries at room temperature). IP Rating IP40. Over-range capability 110 % of range. Dimensions 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L). Weight 550 g (1.2 lb). Fluke 1507 warranty One year.

For more information on Fluke 1507 Insulation Resistance Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title