Sign In
The completely redesigned Fluke 1550C provides unparalleled digital testing of insulation up to 5kV, making it the ideal choice for everything from simple spot checks to timed and breakdown testing of a wide range of electronic equipment including switchgear, motors, generators, and cables. With the Fluke 1550C insulation tester, you can now carry out tests up to 5kV as specified in IEEE 43-2000.
FEATURES
Test voltages to up 5kV and save time by trending on the spot only with Fluke Connect™.
CAT III 1000 V, CAT IV 600 V safety rating.
Warning function alerts the user that line voltage is present.
Selectable test voltages in 50 V steps from 250V to 1000V, and 100V steps above 1000V.
Measurements can be stored in up to 99 memory locations.
Long battery life gives the user over 750 tests between charges.
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup.
Guard system eliminates the effect of surface leakage current on high-resistance measurements.
Large digital/analog LCD for easy viewing.
Capacitance and leakage current measurement.
Ramp function for breakdown testing.
Resistance measurements up to 2 TΩ.
Timer settings up to 99 minutes for timed tests.
Fluke 1550C Specifications
Electrical Specifications
The tester's accuracy is specified for one year after calibration at operating temperatures of 0°C to 35°C. For operating temperatures outside the range (-20°C to 0°C and 35°C to 50°C), add + .25% per °C, except on the 20% bands add + 1% per °C.
Insulation Resistance Measurement
Test voltage (DC)
250 V
Range
< 250 kΩ,
250 kΩ to 5 GΩ
5 GΩ to 50 GΩ
> 50 GΩ
Accuracy (+ reading)
Unspecified
5%
20%
Unspecified
500 V
Range
< 500 kΩ
500 kΩ to 10 GΩ
10 GΩ to 100 GΩ
> 100 GΩ
Accuracy (+ reading)
Unspecified
5%
20%
Unspecified
1000 V
Range
< 1 MΩ
1 MΩ to 20 GΩ
20 GΩ to 200 GΩ
> 200 GΩ
Accuracy (+ reading)
Unspecified
5%
20%
Unspecified
2500 V
Range
< 2.5 MΩ
2.5 MΩ to 50 GΩ
50 GΩ to 500 GΩ
> 500 GΩ
Accuracy (+ reading)
Unspecified
5%
20%
Unspecified
5000 V
Range
< 5 MΩ
5 MΩ to 100 GΩ
100 GΩ to 1 TΩ
> 1 TΩ
Accuracy (+ reading)
Unspecified
5%
20%
Unspecified
Bar graph range
0 to 1 TΩ (1550C) - 0 to 2 TΩ (1555).
Insulation test voltage accuracy
-0%, +10% at 1 mA load current.
Induced AC mains current rejection
2 mA maximum.
Charging rate for capacitive load
5 seconds per µF.
Discharge rate for capacitive load
1.5 s/µF.
Leakage current measurement
Range
1 nA to 2 mA.
Accuracy
+ (5% + 2 nA).
Capacitance measurement
Range
0.01 µF to 15.00 µF.
Accuracy
+ (15% rdg + 0.03 µF).
Timer
Range
0 to 99 minutes.
Resolution setting
1 minute.
Resolution indication
1 second.
Live circuit warning
Warning range
30 V to 660 V AC/DC, 50/60 Hz.
Voltage accuracy
+ (15% + 2 V).
Software specifications
FlukeView Forms™ basic software requires a PC running Windows XP, Windows Vista , Windows 7 or Windows 8.
General Specifications
Display
75 x 105 mm.
Power
12 V lead-acid rechargeable battery, Yuasa NP2.8-12.
Charger Input (AC)
85 V to 250 V AC 50/60 Hz 20 VA.
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only.
Dimensions
269 x 277 x 160 mm (10.6 x 10.9 x 6.3 in).
Weight
3.7 kg (8.2 lb).
Temperature (operating)
-20°C to 50°C (-4°F to 122°F).
Temperature (storage)
-20°C to 65°C (-4°F to 149°F).
Humidity
80% to 31°C decreasing linearly to 50% at 50°C.
Altitude
2000 m.
Enclosure sealing
IP40.
Input overload protection
1000 V AC.
Electromagnetic compatibility
EN 61326.
Safety compliance
IEC 61010-1: Overvoltage category II, Pollution Degree 2.
IEC 61010-2-030: Measurement 600V CAT IV / 1000V CAT III
IEC 61557-1, IEC 61557-2.
For more information on Fluke 1550C/Kit 5kV Insulation Tester talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.