•
•
•RS[kΩ]/RA[Ω]
•
•
•0.2%. Monitoring of RS and RH with error indicator. Automatic range selection. Measurement is not performed if the current through the current clamp is too low. RA 4-Pole Ground Resistance Measurement (IEC 1557-5) Switch position RA 4-pole. Resolution 0.001 Ω to 10 Ω. Measuring range 0.020 Ω to 19.99 kΩ. Accuracy +(2% rdg + 3 d). Operating error +(5% rdg + 3 d). Measuring Principle: Current/Voltage Measurement Measuring voltage Vm = 48 V AC. Short-circuit current > 50 mA. Measure frequency 128 Hz. Probe resistance (RS + RES) Max 100 kΩ. Auxiliary earth electrode resistance (RH) Max 100 kΩ. Additional error from RH and RS RH[kΩ]
•
•
•RS[kΩ]/RA[Ω]
•
•
•0.2%. Monitoring of RS and RH with error indicator. Automatic range selection. RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp ) Switch position RA 3-pole with clamp. Resolution 0.001 Ω to 10 Ω. Measuring range 0.020 Ω to 19.99 kΩ. Accuracy +(7% rdg + 3 d). Operating error +(10% rdg + 5 d). Measuring Principle: Current/Voltage Measurement (with External Current Clamp) Measuring voltage Vm = 48 V AC. Short-circuit current > 50 mA. Measure frequency 128 Hz. Probe resistance (RS) Max 100 kΩ. Auxiliary earth electrode resistance (RH) Max 100 kΩ. Monitoring of RS and RH with error indicator. Automatic range selection. Measurement is not performed if the current through the current clamp is too low. RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp ) Switch position RA 4-pole with clamp. Resolution 0.001 Ω to 10 Ω. Measuring range 0.020 Ω to 19.99 kΩ. Accuracy +(7% rdg + 3 d). Operating error +(10% rdg + 5 d). Measuring Principle: Current/Voltage Measurement (with External Current Clamp) Measuring voltage Vm = 48 V AC. Short-circuit current > 50 mA. Measure frequency 128 Hz. Probe resistance (RS) Max 100 kΩ. Auxiliary earth electrode resistance (RH) Max 100 kΩ. Monitoring of RS and RH with error indicator. Automatic range selection. Measurement is not performed if the current through the current clamp is too low. Stakeless Ground Loop Measurement (2 Clamps) Switch position RA 4-pole 2 clamps. Resolution 0.001 Ω to 10 Ω. Measuring range 0.020 Ω to 19.99 kΩ. Accuracy +(7% rdg + 3 d). Operating error +(10% rdg + 5 d). Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers Measuring voltage Vm = 48 V AC. Measure frequency 128 Hz. Noise current (IEXT) Max. IEXT = 10 A (AC) (RA < 20 Ω). Max. IEXT = 2 A (AC) (RA > 20 Ω). Automatic range selection. The information regarding stakeless ground loop measurements is only valid when used in conjunction with the recommended current clamps at the minimum distance specified.
For more information on Fluke 1623-2 Basic GEO Earth Ground Tester Kit talk to Cuthbertson Laird Group