Find The Needle Add My Company
Fluke 1662 Multifunction Installation Tester
The Fluke 1660 Series Installation Testers are the only installation testers that help prevent damage to connected appliances and also allow users to send test results wirelessly via smartphone directly from the field. The Fluke 1662 tester verifies the safety of electrical installations in domestic, commercial and industrial applications. It can ensure that fixed wiring is safe and correctly installed to meet the requirements of IEC 60364 and all relevant local standards. Reduce test time up to 40% with Auto Test. Auto Test does 5 required installation tests in one sequence, including selectable Type A, AC & RCD Auto Test, ensuring compliance with local installation regulations. It reduces the number of manual connections, decreases the possibility of making errors and reduces test time up to 40 % from previous Fluke models. FEATURES Voltage & frequency. Wiring polarity checker, detects broken N wires. Insulation resistance. Continuity & resistance. Measure motor windings with continuity test. Loop & line resistance. Prospective earth fault current (PEFC/IK). Prospective short-circuit current (PSC/IK). RCD switching time. RCD tripping level (ramp test). Measures trip time & current for RCD type A & AC in one test. RCD variable current. Automatic RCD test sequence. Phase sequence indicator. On/Off switchable Auto Start for RCD and Looptest. Self-test. Illuminated display. Fluke 1662 Specifications: AC Voltage Measurement Range 500 V. Resolution 0.1 V. Accuracy (45 Hz - 66 Hz) 0.8% + 3. Input impedance 360 kΩ. Overload protection 660 V rms. Continuity Testing (RLO) Range (autoranging) 20 Ω / 200 Ω / 2000 Ω. Resolution 0.01 Ω / 0.1 Ω / 1 Ω. Open Circuit Voltage >4 V. Insulation Resistance Measurement (RISO) Test voltages 50-100-250-500-1000 V. Accuracy of Test voltage (at rated test current) +10%, -0%. Test voltage 100 V 250 V 500 V 1000 V Insulation resistance range 20 MΩ /50 MΩ 20 MΩ / 100 MΩ 20 MΩ / 200 MΩ 20 MΩ / 200 MΩ / 500 MΩ 20 MΩ / 200 MΩ / 1000 MΩ Resolution 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ 0.01 MΩ / 0.1 MΩ / 1 MΩ Test current 1 mA @ 50 kΩ 1 mA @ 100 kΩ 1 mA @ 250 kΩ 1 mA @ 500 kΩ 1 mA @ 1 MΩ Loop & Line Impedance (ZI) Range 10 Ω / 0.001 Ω / High current mΩ mode. Resolution 0.01 Ω / 0.1 Ω / 1 Ω. Prospective Earth Fault Current, PSC Test Range 1000 A / 10 kA (50 kA). Resolution 1 A / 0.1 kA. RCD Testing, RCD Types Tested RCD Type A4, AC¹, G?, S? Notes ¹Responds to AC ?General, no delay ?Time delay 4Responds to pulsed signal 5Responds to smooth DC signal Tripping Speed Test (?T) Current settings¹ 10-30-100-300-500-1000 mA - VAR 10-30-100 mA Multiplier x ½, x 1, x 5 Notes � mA type AC only 700 mA maximum type A in VAR mode VAR mode not available for type B. General Specifications Battery size, quantity Type AA, 6 ea. Sealing IP-40. Dimensions (L x W x H) 10 x 25 x 12.5 cm. Weight (incl. batteries) 1.3 Kg. Fluke 1662 warranty 3 years.

For more information on Fluke 1662 Multifunction Installation Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title