Find The Needle Add My Company
Fluke 1748 Three-Phase Power Quality Logger
Power Quality Logger with 60 cm 1,500A iFlex The Fluke 1748 Power Quality Logger is a compact device for technicians and engineers to troubleshoot, quantify energy usage, and analyse power distribution systems. The Fluke 1748 is compliant with international standards such as IEC 61000-4 -30 and IEC 62586. The 1746 can simultaneously log up to 500 parameters and capture events to find intermittent and hard-to-find power quality issues. The Fluke 1748 logs over 500 different parameters for each averaging period. This allows you to analyze power quality in detail and to correlate intermittent events with detailed waveform data, helping to identify the root cause of disturbances. An optimised user interface, flexible current probes, and an intelligent measurement verification function that allows you to digitally verify and correct connections makes setup easier than ever and reduces measurement uncertainty. Minimize your time in potentially hazardous environments and reduce the hassle of suiting up in PPE by using a wireless connection (WiFi) to view data directly in the field. The included Energy Analyze Plus software enables thorough analysis of the captured data and reporting according to national and international standards such as EN 50160. Power Quality Monitoring: Fluke 1746 and 1748 Power Quality Loggers FLUKE 1740 MODEL FEATURES 1742 Power Logger 1746 Power Logger 1748 Power Logger FUNCTIONS Voltage, current, power, power factor, frequency Y Y Y Energy forward/reverse Y Y Y Peak Demand Y Y Y THD Y Y Y Voltage and current harmonics (to 50th)1 Y Y Flicker Y Y Y Unbalance1 Y Y Rapid voltage change events1 Y Y Interharmonics (to 50th)1 Y Y Dips, swells, interruption and transient events tables1 Y Y Mains signaling1 Y Y Inrush current1 Y Y Transients (low frequency)/Waveform deviation events2 Y RECORDING Trend Y Y Y Waveform snapshots2 Y RMS profile2 Y COMMUNICATION Ethernet Y Y Y USB (mini B) Y Y Y WiFi download Instrument to device Y Y Y Wifi download via WiFi hub (requires registration) Opt. Opt. Opt. 1Included with 1742-6/UPGRADE option 2Included with 1742-8/UPGRADE or 1746-8/UPGRADE option FLUKE 1740 SERIES SPECIFICATIONS Voltage Range: 1000 V Maximum resolution: 0.1 V. Current: Direct input See datasheet. Frequency Range: 42.5 Hz to 69 Hz Maximum resolution: 0.01 Hz. Auxiliary input Range: +10 V dc Maximum resolution: 0.1 mV. Electrical Specifications Power Supply Voltage range 100 V to 500 V using safety plug input when powering from the measurement circuit. 100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7). Power consumption Maximum 50 VA (max. 15 VA when powered using MA-C8 adapter). Mains power frequency 50/60 Hz +15%. Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable. On-battery runtime Typically 4 hours. Charging time < 6 hours. Data Acquisition Resolution 16-bit synchronous sampling. Sampling frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency. Input signal frequency 50/60 Hz (42.5 to 69 Hz). Circuit types 1-?, 1-? IT, split phase, 3-? delta, 3-? wye, 3-? wye IT, 3-? wye balanced, 3-? Aron/Blondel (2-element delta), 3-? delta open leg, currents only (load studies). Data storage Internal flash memory (not user replaceable). Memory size Typical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events. Basic Interval Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy. Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min. Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms). Demand Interval (Energy Meter Mode) Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy. Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off. Power Quality Measurements Measured parameter Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation. Averaging interval 10 min for all parameters 2 hrs (long term Flicker PLT) 150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT). Individual harmonics 2nd to 50th harmonic Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only. Interharmonics 1st to the 50th interharmonic. Events Voltage: dips, swells, interruptions, current: inrush current 1748: mains signaling, transients (low frequency). Inrush RMS profile based on 1/2 cycle RMS steady state triggering. Flicker In accordance with IEC 61000-4-15 and IEEE 1453. Programmable PQ limits Enables user defined limits for local standards compliance. Interfaces. USB-A File transfer via USB flash drive, firmware updates, max. supply current: 120 mA. WiFi File transfer and remote control via direct connection or WiFi infrastructure. Bluetooth Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or WiFi/BLE adapter, check for availability). USB-mini Data download device to PC. Voltage Inputs Number of inputs 4 (3 phases referenced to neutral). Maximum input voltage 1000 Vrms, CF 1.7. Input impedance 10 MΩ. Measurement category 1000 V CAT III/600 V CAT IV. Current Inputs Number of inputs 4 (3 phases and neutral), mode selected automatically for attached sensor. Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8. Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4 all at nominal probe range. Auxiliary Inputs Number of inputs 2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously). Input range 0 to + 10 V dc, or 0 to + 1000 V dc (with optional adapter), 1 reading/s. Displayed units User configurable (7 characters, for example, °C, psi, or m/s). General Specifications Operating temperature -25 °C to +50 °C (-13 °F to 122 °F)1. Enclosure IEC 60529: IP50. IEC 60529: IP65 with IP65 rated voltage connector. 1Warm up the product to -10 °C (+14 °F) before you power the unit on Weight Instrument: 1 kg (2.2 lb). Dimensions 23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in). Fluke 1748 warranty Two-years (battery not included). Accessories: one-year.

For more information on Fluke 1748 Three-Phase Power Quality Logger talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title