• Voltage
• Current
• Power P, Q, S
• Power Factor
• kWh
• Flicker
• Unbalance
• Frequency
• Harmonics/Interharmonics continuously with the following time aggregations: Day, 10 min, Free Interval, e.g.: 15 min, 2 h Triggered recordings rms Aggregation time is adjustable between 10 ms (1/2 cycle), 20 ms (1 cycle), 200 ms (10/12 cycles) or 3 sec (150/180 cycles). Calculating rms values, Harmonics and Interharmonics is performed synchronous to the power frequency. Basic aggregation for harmonics and interharmonics is 200 ms. Sample rate is 10.24 kHz for all 8 channels. Mains signalling Phases and N-conductor, Voltage and current. Online mode Variable refresh rate. This feature allows verification of instrument set up and delivers a quick overview of oscilloscope, transients and events. General Data Intrinsic uncertainty refers to reference conditions and is guaranteed for two years. Quality system developed, manufactured as per ISO 9001: 2000. Environment conditions Operating temp. range 0°C to +50°C; 32°F to +122°F. Working temp. range -20°C to +50°C; -4°F to +122°F. Storage temp. range 20°C to +60°C; -4°F to 140°F. Reference temperature 23°C +2 K; 74°F +2 K. Climatic class B2 (IEC 654-1), -20°C to +50°C; -4°F to +122°F. Max. operating altitude 2000 m: max. 600 V CAT IV1 power supply: 300 V CAT III 5000 m: max 600 V CAT III1 power supply: 300 V CAT II. 1. Depending on sensor. Reference conditions Environment temperature 23°C +2 K ; 74°F +2 K. Power supply 230 V +10%. Power frequency 50 Hz / 60 Hz. Signal declared input voltage Udin. Averaging 10 minute intervals. Housing Insulated, robust plastics housing. EMC Emission Class-A as per IEC/EN 61326-1. Immunity IEC/EN 61326-1. Power supply Range AC: 83 V to 264 V, 45 to 65 Hz. DC: 100 V to 375 V. Safety IEC/EN 61010-1 2nd edition. 300 V CAT III. Power consumption NIMH, 7.2 V, 2.7 Ah. Battery pack In case of a power supply failure an internal battery maintains the supply for up to 40 minutes. Afterwards, or in case of discharged accumulators the Fluke 1760 is turned off and continues the measurements with the latest settings as soon as the supply voltage returns. The battery can be replaced by the user. Display Fluke 1760 features LED indicators for the status of the 8 channels, phase sequence, power supply (mains or accumulator), memory usage, time synchronization, and data transfer. Power LED Permanent light: normal power supply from mains. OFF: supply via internal accumulator in case of a power failure. Channel LEDs 3-colour LEDs per channel for Overload condition Under load condition. Data memory 2 GB Flash memory. Memory model Linear. Interfaces Ethernet (100 MB/s), compatible to Windows® XP, 7 and 8, RS 232, external modem via RS 232. Baud rate for RS 232 9600 Baud to 115 kBaud. Dimensions (H x W x D) 325 x 300 x 65 mm; 2.8 x 11.8 x 2.6 in. Weight appr. 4.9 kg; 10.8 lbs (without accessories). Fluke 1760 Warranty 2 years. Calibration interval 1 year recommended for Class-A, otherwise 2 years. Signal Conditioning Range for 50 Hz systems 50 Hz +15% (42.5 Hz to 57.5 Hz). Range for 60 Hz systems 60 Hz +15% (51 Hz to 69 Hz). Resolution 16 ppm. Sampling frequency for 50 Hz power frequency 10.24 kHz, The sampling rate is synchronized to mains frequency. Uncertainty for frequency measurements < 20 ppm. Uncertainty of internal clock < 1 s / day. Measurement intervals Aggregation of the interval values as per IEC 61000-4-30 Class-A. Min-, Max-values Half cycle, e.g.: 10 ms rms values at 50Hz. Transients Sample rate 100 kHz to 10 MHz per channel. Harmonics as per IEC 61000-4-7:2002: 200 ms. Flicker as per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt). Measurement Inputs Number of inputs 8 galvanically isolated inputs for voltage and current measurements. Sensor safety up to 600 V CAT IV depending on sensor. Basic safety 300 V CAT III. Nominal voltage (rms) 100 mV. Range (peak value) 280 mV. Overload capacity (rms) 1000 V, continuously. Voltage rise rate max. 15 kV / ?s. Input resistance 1 M?. Input capacitance 5 pF. Input filter Each channel is equipped with a passive low-pass filter, an anti-aliasing filter and a 16-bit A/D converter. All channels are sampled synchronously with a common quartz-controlled clock pulse. The filters protect against voltage transients and limit the signal rise rate, reduce high frequency components and especially the noise voltage above half the sampling rate of the A/D converter by 80 dB, thus achieving very small measuring errors in an exceptionally large amplitude range. This is also valid under extreme operating conditions like transient voltages at the output of converters. Uncertainties Uncertainty at reference conditions Uncertainty including the voltage sensors is in compliance with IEC 61000-4-30 Class-A. All voltage sensors are suitable for DC up to 5 kHz. With Sensor 1000 V 0,1% at Udin = 480 V and 600 V P-N. Sensor 600 V 0,1% at Udin = 230 V P-N. Intrinsic uncertainty for harmonics Class I as per EN 61000-4-7:2002. Reference conditions 23°C +2 K < 60% rH; 74°F +2 K < 60% rH. Warmed up instrument > 3h. Power supply: 100 V to 250 V AC. Temperature drift 100 ppm / K. Aging < 0.05% / year. Common mode rejection > 100 dB at 50 Hz. Temperature drift Change of amplification through temperature: < 0.005%/K. Aging Change of amplification due to ageing: < 0.04%/year. Noise Noise voltage, input short-circuited: < 40 ?V. DC +(0.2% rdg + 0.1% sensor).
For more information on Fluke 1760TR Power Quality Recorder Topas talk to Cuthbertson Laird Group