Fluke 1777 Three-Phase Power Quality Analyser
The Fluke 1777 3-Phase Power Quality Analyser is a rugged, portable device for troubleshooting power quality. The compact size and power supply from the measurement line makes it a versatile tool for live measurements and long-term logging. Fluke 1770 Series Three-Phase Power Quality Analysers eliminate the complexities of power quality logging, troubleshooting, and analysis. Engineered to be the faster, easier way to perform power quality studies, the 1770 Series offers automatic measurements, a straightforward user interface and setup, best-in-class specifications, and a simplified reporting platform. The instrument can also be powered directly from the measurement circuit, eliminating the need to find a power outlet or use a lengthy extension cord. The Fluke 1770 Series are 2-in-1 devices that combine the trouble-shooting functionality of a power quality meter with the robust analysis and logging capabilities of a standalone power quality analyser - in a single, easy-to-use, handheld device. WiFi/BLE Module (Not supplied with the Basic models). The WiFi/BLE module enables the wireless connectivity. Wireless connectivity is the preferred data transfer method when the Product is installed in hazardous environments, such as, cabinets. The WiFi/BLE module enables these features: Wireless data transfer to Energy Analyze Plus PC software. Time synchronization with NTP. Remote control via Virtual Network Computing (VNC). See Remote Display for more information about VNC. A WiFi/BLE Module is included and pre-installed. If necessary, the module is removable or you can install a module to upgrade a basic model. FEATURES 3-Phase voltage measurement inputs with reference to N and N-to-PE measurement. 4 current measurement inputs for 3-phases and Neutral. 2 auxiliary measurement inputs for measurements of non-electrical units: temperature, humidity, light intensity. Power supply 100 V ac to 600 V ac and 100 V dc to 660 V dc with safety sockets for powering from measurement line. 7-inch display with capacitive touch. GPS time synchronisation. USB interfaces: Type A for Flash drives and USB-C for wired connection to PC and power supply. Slot for Wi-Fi/BLE module. Slot for LTE-4G module. Ethernet 1000Base-T. User-accessible micro SD slot for flash memory expansion. APPLICATIONS 1773 1775 1777 Energy surveys and load testing

• Harmonic surveys

• Nuisance circuit breaker tripping

• Power utility power quality surveys

• Discovery of equipment failures caused by transients

• From traditional industrial systems to renewable energy systems to electric vehicles.... Fluke 1770 Series Included Accessories Model ITEM 1773 1773/B 1775 1775/B 1777 1777/B 4x Fluke-17XX IFLEX 1500 A 24 IN, 2.0 M - - - Voltage Test Lead, 3-phase + N 4x AC285 (Black) 1x AC285 (Green) 1x Black 1M USB-C cable 1x Mains 1x FLK-17XX 0.18M test lead set. 1x Green test lead 3x Red Magnet Probes, 1 Black - - - - Hanger kit - - - - WiFi/BLE Module - - - - Cable Marker Set (V & A) Wall Outlet Adapter Statement Of calibration Practices Black Soft Case Fluke 1777 Hard Case - - Fluke 1770 Series Three-Phase Power Quality Analyser Specifications Voltage inputs Number of inputs 4 inputs, 3 phases and neutral referenced to PE (5 connectors). Measurement category 1000 V CAT III / 600 V CAT IV Maximum input voltage 1000 V rms / 1000 V dc (1700 Vpk) Nominal voltage range Wye and single phase: variable (50 V - 1000 V) Delta: Variable (100 V - 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V - 690 V Input impedance 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE Bandwidth DC to 30 kHz for PQ measurements, excluding transients Resolution 24-bit synchronous sampling Sampling frequency 80 kS/s at 50/60 Hz Scaling 1:1, variable for use of potential transformers Voltage transients Measurement range +8 kV Sampling rate 1775: 1 MS/s 1777: 1 MS/s, 20 MS/s Bandwidth DC to 1 MHz Trigger Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz Resolution 14-bit synchronous sampling Current inputs Number of inputs 4 inputs 3 phases and Neutral, range selected automatically to attached sensor Range AC 1 A to 1500 A with i17XX-FLEX1500 12 1 A to 1500 A with i17XX-FLEX1500 24 3 A to 3000 A with i17XX-FLEX3000 24 6 A to 6000 A with i17XX-FLEX6000 36 40 mA to 40 A with clamp i40s-EL 4 A to 400 A with clamp i400s-EL DC 20 A to 2000 A with 80i-2010-EL clamp Bandwidth DC to 30 kHz Resolution 24-bit synchronous sampling Sampling frequency 80 kS/s at 50/60 Hz Scaling 1:1, variable Input voltage Clamp: 50 mV / 500 mV rms; CF 2.8 Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4 all at nominal probe range Input impedance 11 kΩ Aux inputs Wired connection with 17XX-AUX adapter. Number of inputs 2 Input range Direct: 0 V dc to + 10 V dc 0 V to 1000 V dc. Input impedance Direct: 2.92 MΩ. Scale factor Format: mx + b (gain and offset) user configurable. Displayed units User configurable (up to 8 characters, for example °C, psi, or m/s). Data acquisition voltage and current Input mains frequency DC, 50/60 Hz ?15 % (42.5 Hz . 57.5 Hz, 51 Hz . 69 Hz). Topologies 1-?, 1-? IT, Split phase, 3-? delta, 3-? wye IT, 3-? Aron/Blondel (2 element delta), 3-? delta open leg, 3-? high leg delta. Data storage Fluke 1773/1775: 8 GB internal (expandable with microSD card) Fluke 1777: 32 GB microSD card (installed). Memory size Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events. The number of possible logging sessions and logging period depends on user requirements. Real time accuracy Internal: 3 ppm (0.26 s per day, 8 s per month) NTP (internet time): Depending on internet latency, typical < 0.1 s absolute to UTC GPS: < 1 ms absolute to UTC. Trend interval Measured parameter See operator manual. Trend interval User selectable: 1 sec, 3 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min. Averaging interval min/max values Voltage, Current: ½ cycle RMS (20 ms at 50 Hz, 16.7 ms at 60 Hz) Aux, Power: 200 ms. Total harmonic distortion THD for voltage and current is calculated on 50 harmonics. Power quality measurements Measured parameter See operator manual. Harmonics h0 . h50 % fund and RMS for voltage, current and power Phase angles for voltage and current up to h11. Interharmonics ih0. ih50 % fund and RMS for voltage and current. Supraharmonics 2-9 kHz with 200 Hz bins 9-30 khz with 2 kHz bins RMS for voltage and current. Harmonics measurement method Grouped, sub-grouped and single harmonic bins according to IEC 61000-4-7. Method selected automatically based on configured PQ standard or user configurable. Total harmonic distortion Calculated on up to 50 harmonics (depends on selected PQ standard). Mains signaling 2 frequencies in the range from 110 Hz to 3000 Hz. Events Voltage Dip, swell, interruption, rapid voltage change, mains signaling, waveshape deviation, transients. Current Inrush current. Triggered recordings Half cycle RMS of voltage and current for 10 s Waveform of voltage and current for 10/12 cycles Mains signaling: 200 ms RMS of mains signaling voltage up to 120 s Transients: Waveform of voltage (Fluke 1777: 1 MS/s or 20 MS/s, 500,000 pts, Fluke 1775: 1 MS/s, 25,000 pts). Standard compliance Power IEEE 1459 Harmonics IEC 61000-4-7: Class 1 IEEE 519 (short time and very short time harmonics). Flicker IEC 61000-4-15 Class F1. Power quality IEC 61000-4-30 Class A, IEC 62586 PQI-A-PI. Power quality compliance EN 50160 + GOST + NEQUAL + NETCODE + FOL. Interfaces Ethernet 1 Gbit/s 1000BASE-T. USB type A USB 2.0 high speed for USB flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 500 mA USB-C USB 2.0 high speed for data download to PC and calibration (requires USB type A to USB-C or USB-C to USB-C cable) Auxiliary power supply for the Analyzer (requires USB C power adapter PD 2.0 or higher with 9 V 1.8 A support) USB 3.0 super-speed for USB-C flash drives to transfer measurement data, firmware updates and license installation. Max. supply current: 900 mA. WiFi/BLE module1 802.11 ac 2.4 GHz / 5 GHz, support for concurrent access point and client mode Bluetooth 5.0/BLE Antenna: Internal and external2. LTE/4G module3 LTE-A Cat 12 Worldwide LTE-A and UMTS/HSPA+ coverage Antenna: External2. GPS MCX connector to attach a GNSS antenna for GPS/GLONASS2. 1 Not in 177X/BASIC versions 2 Requires 5m extension cable, Fluke p/n 5263915 3 Availability and supported providers vary by country. Check with your local Fluke representative. General Specifications Key features Warranty Analyser: 2 years (battery not included) Accessories: 1 year (including battery). Calibration cycle 2 years. Size (L X W X HD) 28.0 cm x 19.0 cm x 6.2 cm (11.0 in x 7.5 in x 2.4 in). Weight 2.1 kg (4.6 lb). Anti-theft protection Slot to support Kensington lock. Environmental specifications Operating temperature range -10 °C to 50 °C. Storage temperature range -20 °C to 60 °C. Operating humidity IEC 60721-3-3: 3K5, modified: -10 °C to 30 °C: ?95 %, no condensation or ice 35 °C: 70 % 40 °C: 55 % 50 °C: 35 % IP Rating IEC 60529: IP50. Vibration IEC 60721-3-3 / 3M2. Power supply Voltage range 100 V - 600 V -15 % / +10 % (85 V . 660 V). Power consumption Max. 40 VA. Mains frequency 50/60 Hz (42.5 Hz . 69 Hz). UPS Li-Ion battery BP1770 with extended temperature range, customer replaceable On-battery runtime: 1.5 hours. Safety General IEC 61010-1: Pollution Degree 2. Power supply Overvoltage Category IV 600 V With Mains Adapter MA-C8: Overvoltage Category II 300 V. Measurement IEC 61010-2-030: CAT IV 600 V, CAT III 1000 V. Altitudes 2000 m to 4000 m Derate to: Power Supply: Category IV 300 V With MA-C8 Adapter: Category II 150 V Measurement: CAT IV 300 V, CAT III 600 V, CAT II 1000 V.

For more information on Fluke 1777 Three-Phase Power Quality Analyser talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title