Find The Needle Add My Company
Fluke 28 II Industrial Multimeter
The Fluke 28-II multimeter defines a new standard for operation in harsh conditions and is packed with the features and accuracy needed to troubleshoot most electrical problems. In addition to the features of the Fluke 27-II, the Fluke 28-II has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment. This digital multimeter will also withstand hazardous 8000V spikes caused by load switching and faults on industrial circuits, and fully complies with 2nd Edition IEC and ANSI electrical safety standards. When enclosed in its protective yellow holster, the Fluke 28II meter will float in fresh or salt water. Holsters are reversible to protect the display and controls in storage. Both meters feature backlit keypad buttons, large display digits and display backlighting for easy visibility in low-lit areas. FEATURES Measure up to 1000 V ac and dc. Measure up to 10 A (20 A for 30 seconds). 10,000 µF capacitance range. Frequency to 200 kHz. Extended ac voltage bandwidth- 15 Hz to 20 kHz. Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument. Resistance, continuity and diode test. IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments. Designed to withstand 3 meter drop (with holster). Hi resolution 20,000 count display mode. True-rms ac voltage and current for accurate measurements on non linear signals. Backlit keypad buttons allow for easy visibility in low lit areas. Large display digits and 2 level bright white backlight for increased visibility. Fluke 28-II Product Video Fluke 28-II Specifications DC voltage Range: 0.1 mV to 1000 V. Accuracy: 0.05 % + 1. AC voltage Range: 0.1 mV to 1000 V. Accuracy: 0.7 % +4. DC current Range: 0.1 µA to 10 A. Accuracy: 0.2 % + 4. AC current Range: 0.1 µA to 10 A. Accuracy: 1.0 % + 2. Resistance Range: 0.1 Ω to 50 MΩ. Display counts 6000 / 19,999. Capacitance 1 nF to 9999 µF. Frequency 0.5 Hz to 199.99 kHz. Temperature -200 °C to +1090 °C. Low pass filter (Measurement on VSD’s) Yes. Compliance CAT IV 600 V , CAT III 1000V. IP Rating IP 67. Display Bar graph / backlight. Data storage Peak transient capture: 250 µS. Min/Max/Avg: Yes. Reading hold: Yes. Power Three AA batteries. Battery life 800 hours. Safety rating CAT IV 600 V/CAT III 1000 V. Drop test 10 feet. Dimensions (with holster) 6.35 cm x 10.0 cm x 19.81 cm (2.5 in x 3.93 in x 7.8 in). Weight (with holster) 698.5 g (1.54 lb). Fluke 28II warranty Limited lifetime.

For more information on Fluke 28 II Industrial Multimeter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title