The Fluke 3000 FC General Maintenance System lets you work on electrical panels faster, safer, easier.
Connect the FC Wireless iFlex AC Current Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Or connect the FC Wireless AC Voltage Module and view both voltage and current measurements simultaneously.
You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements.
FEATURES
Fluke 3000 FC Series Wireless Multimeter:
AC and DC voltage measurements to 1000V.
AC and DC current with 0.01 mA resolution.
Continuity, resistance, diode test, capacitance and frequency measurements.
MIN/MAX recording.
CAT III 1000 V, Cat IV 600 V; IP54.
Fluke v3000 FC Wireless AC Voltage Module:
Measurements up to 1000 V true-RMS AC.
Use as a standalone meter or as part of the system.
A logging function for recording and saving up to 65,000 readings.
Fluke v3001 FC Wireless DC Voltage Module:
Measure up to 1000 V DC.
Use as a standalone meter or as part of the system.
Use the logging function for recording and saving up to 65,000 readings.
Fluke a3001 FC Wireless iFlex AC Current Module:
Measure up to 2500 A AC.
Use as a standalone meter or as part of the system.
Logging function for recording and saving up to 65,000 readings.
Inrush function.
Introducing Fluke Connect: See it. Save it. Share it.
Fluke 3000 FC Wireless Multimeter Specifications
AC Voltage
Range
Resolution
Accuracy
45 Hz to 500 Hz
500 Hz to 1 KHz
600.0 mV
0.1 mV
1.0% + 3
2.0% + 3
6.000 V
0.001 V
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
Note
All AC voltage ranges are specified from 1% of range to 100% of range.
Crest factor of ? 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
For non sinusoidal waveforms, add + (2% of reading + 2% of full scale) typical, for crest factor up to 3.
Do not exceed 10V Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
Range
Resolution
Accuracy
mV
600.0 mV
0.1 mV
0.09% + 2
V
6.000 V
0.001 V
0.09% + 2
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
0.15% + 2
Ω
600.0 Ω
0.1 Ω
0.5% + 1
6.000 kΩ
0.001 kΩ
60.00 kΩ
0.01 kΩ
60.00 kΩ
0.1 kΩ
600.0 kΩ
0.001 MΩ
50.00 MΩ
0.01 MΩ
1.5% + 3
Diode Test
2.000 V
0.001 V
1% + 2
µF
1000 nF
1 nF
10% typical
10.00 µF
0.01 µF
100.0 µF
0.1 µF
9999 µF
1 µF
Note
In the 9999 µF range for measurements to 1000µF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
Range
Resolution
Accuracy
mA AC (45 Hz to 1 KHz)
60.00 mA
0.01 mA
1.5% + 3
400.0 mA
mA DC
60.00 mA
0.01 mA
0.5% + 3
400.0 mA
0.1 mA
Note
All AC current ranges are specified from 5% of range to 100% of range
Input burden voltage (typical): 400 mA input 2 mV/mA
400.0 mA accuracy specified up to 600mA overload.
Frequency
Range
Resolution
Accuracy
99.99 Hz
0.01 Hz
0.1% + 1
999.9 Hz
0.1 Hz
9.999 kHz
0.001 Hz
99.99 kHz
0.01 kHz
Input Characteristics
Function
Overload Protection
Input Impedance (Nominal)
Common Mode Rejection Ratio (1kΩ Unbalance)
Normal Mode Rejection
1100 V rms
>10 MΩ < 100 pF
> 120 dB at dc, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
1100 V rms
>10 MΩ < 100 pF
> 60 dB, dc to 60 Hz
1100 V rms
>10 MΩ < 100 pF
> 120 dB at dc, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage
Full Scale Voltage
Typical Short Circuit Current
1100V rms
<2.7V DC
To 6 MΩ: <0.7 V DC
50 MΩ: <0.9 V DC
<350 mA
1100V rms
<2.7V DC
2.000V DC
<1.1 mA
Function
Overload Protection
Overload
mA
Fused, 44/100 A, 1000 V FAST Fuse
600 mA overload for 2 minutes maximum, 10 minutes rest minimum.
MIN/MAX Recording
Function
Accuracy
DC Functions
The specified accuracy of the measurement function + 12 counts for changes > 350 ms in duration.
AC Functions
The specified accuracy of the measurement function + 40 counts for changes > 900 ms in duration.
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground
1000 V DC or AC RMS
Ω Fuse Protection From A Inputs
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only.
Display (LCD)
Update rate: 4/sec
Votls, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts.
Battery Type
3 x AA alkaline batteries, NEDA 15A IEC LR6.
Battery Life
250 hours maximum.
RF Communications
2.4 GHZ ISM Band.
RF Communication Range
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m.
Temperature
Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Temperature Coefficient
0.1 X (specified accuracy) /°C (<18 °C or >28 °C)
Relative Humidity
0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
Altitude
Operating: 2,000 m
Storage: 12,000 m.
Electromagnetic Compatability EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249,
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE.
Safety Compliance
ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010.
Certifications
CSA, FCC, CE.
Ingress Protection (IP) Rating
IP54.
Pollution Degree
2.
Size (H x W x L)
4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in)
Weight
340g (12oz).
Fluke 3000 FC GMS warranty
3 years.
Fluke v3000 FC Wireless AC Voltage Module
Accuracy is specified as + ([% of reading] + [number of least significant digits]). All ranges are autoranging.
Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.
Specifications
Range1
Resolution
Accuracy2,3,4
45 Hz to 500 Hz
500 Hz to 1 kHz
6.000 V
0.001 V
1.0 % + 3
2.0 % + 3
60.00 V
0.01 V
600.0 V
0.1 V
1000 V
1 V
AC Voltage
1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ? 3 at full scale up to 500 V, decreasing linearly to crest factor ? 1.5 at 1000 V.
3 For non-sinusoidial waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4 Do not exceed 106 V-Hz.
For more information on Fluke 3000 FC General Maintenance System talk to Cuthbertson Laird Group