Find The Needle Add My Company
Fluke 3000 FC General Maintenance System
The Fluke 3000 FC General Maintenance System lets you work on electrical panels faster, safer, easier. Connect the FC Wireless iFlex AC Current Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Or connect the FC Wireless AC Voltage Module and view both voltage and current measurements simultaneously. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements. FEATURES Fluke 3000 FC Series Wireless Multimeter: AC and DC voltage measurements to 1000V. AC and DC current with 0.01 mA resolution. Continuity, resistance, diode test, capacitance and frequency measurements. MIN/MAX recording. CAT III 1000 V, Cat IV 600 V; IP54. Fluke v3000 FC Wireless AC Voltage Module: Measurements up to 1000 V true-RMS AC. Use as a standalone meter or as part of the system. A logging function for recording and saving up to 65,000 readings. Fluke v3001 FC Wireless DC Voltage Module: Measure up to 1000 V DC. Use as a standalone meter or as part of the system. Use the logging function for recording and saving up to 65,000 readings. Fluke a3001 FC Wireless iFlex AC Current Module: Measure up to 2500 A AC. Use as a standalone meter or as part of the system. Logging function for recording and saving up to 65,000 readings. Inrush function. Introducing Fluke Connect: See it. Save it. Share it. Fluke 3000 FC Wireless Multimeter Specifications AC Voltage Range Resolution Accuracy 45 Hz to 500 Hz 500 Hz to 1 KHz 600.0 mV 0.1 mV 1.0% + 3 2.0% + 3 6.000 V 0.001 V 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V Note All AC voltage ranges are specified from 1% of range to 100% of range. Crest factor of ? 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. For non sinusoidal waveforms, add + (2% of reading + 2% of full scale) typical, for crest factor up to 3. Do not exceed 10V Hz. DC Voltage, Continuity, Resistance, Diode Test and Capacitance Function Range Resolution Accuracy mV 600.0 mV 0.1 mV 0.09% + 2 V 6.000 V 0.001 V 0.09% + 2 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V 0.15% + 2 Ω 600.0 Ω 0.1 Ω 0.5% + 1 6.000 kΩ 0.001 kΩ 60.00 kΩ 0.01 kΩ 60.00 kΩ 0.1 kΩ 600.0 kΩ 0.001 MΩ 50.00 MΩ 0.01 MΩ 1.5% + 3 Diode Test 2.000 V 0.001 V 1% + 2 µF 1000 nF 1 nF 10% typical 10.00 µF 0.01 µF 100.0 µF 0.1 µF 9999 µF 1 µF Note In the 9999 µF range for measurements to 1000µF, the measurement accuracy is 1.2% + 2. AC and DC Current Function Range Resolution Accuracy mA AC (45 Hz to 1 KHz) 60.00 mA 0.01 mA 1.5% + 3 400.0 mA mA DC 60.00 mA 0.01 mA 0.5% + 3 400.0 mA 0.1 mA Note All AC current ranges are specified from 5% of range to 100% of range Input burden voltage (typical): 400 mA input 2 mV/mA 400.0 mA accuracy specified up to 600mA overload. Frequency Range Resolution Accuracy 99.99 Hz 0.01 Hz 0.1% + 1 999.9 Hz 0.1 Hz 9.999 kHz 0.001 Hz 99.99 kHz 0.01 kHz Input Characteristics Function Overload Protection Input Impedance (Nominal) Common Mode Rejection Ratio (1kΩ Unbalance) Normal Mode Rejection 1100 V rms >10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz 1100 V rms >10 MΩ < 100 pF > 60 dB, dc to 60 Hz 1100 V rms >10 MΩ < 100 pF > 120 dB at dc, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz Open Circuit Test Voltage Full Scale Voltage Typical Short Circuit Current 1100V rms <2.7V DC To 6 MΩ: <0.7 V DC 50 MΩ: <0.9 V DC <350 mA 1100V rms <2.7V DC 2.000V DC <1.1 mA Function Overload Protection Overload mA Fused, 44/100 A, 1000 V FAST Fuse 600 mA overload for 2 minutes maximum, 10 minutes rest minimum. MIN/MAX Recording Function Accuracy DC Functions The specified accuracy of the measurement function + 12 counts for changes > 350 ms in duration. AC Functions The specified accuracy of the measurement function + 40 counts for changes > 900 ms in duration. General Specifications Maximum Voltage Between Any Terminal and Earth Ground 1000 V DC or AC RMS Ω Fuse Protection From A Inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only. Display (LCD) Update rate: 4/sec Votls, amps, ohms: 6000 counts Frequency: 10,000 counts Capacitance: 1,000 counts. Battery Type 3 x AA alkaline batteries, NEDA 15A IEC LR6. Battery Life 250 hours maximum. RF Communications 2.4 GHZ ISM Band. RF Communication Range Open air, unobstructed: Up to 20 m Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m. Temperature Operating: -10 °C to 50 °C Storage: -40 °C to 60 °C Temperature Coefficient 0.1 X (specified accuracy) /°C (<18 °C or >28 °C) Relative Humidity 0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C) Altitude Operating: 2,000 m Storage: 12,000 m. Electromagnetic Compatability EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006. ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249, FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE. Safety Compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010. Certifications CSA, FCC, CE. Ingress Protection (IP) Rating IP54. Pollution Degree 2. Size (H x W x L) 4.75 cm x 9.3 cm x 20.7 cm (1.87 in x 3.68 in x 8.14 in) Weight 340g (12oz). Fluke 3000 FC GMS warranty 3 years. Fluke v3000 FC Wireless AC Voltage Module Accuracy is specified as + ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C. Specifications Range1 Resolution Accuracy2,3,4 45 Hz to 500 Hz 500 Hz to 1 kHz 6.000 V 0.001 V 1.0 % + 3 2.0 % + 3 60.00 V 0.01 V 600.0 V 0.1 V 1000 V 1 V AC Voltage 1 All ac voltage ranges are specified from 1 % of range to 100 % of range. 2 Crest factor of ? 3 at full scale up to 500 V, decreasing linearly to crest factor ? 1.5 at 1000 V. 3 For non-sinusoidial waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3. 4 Do not exceed 106 V-Hz.

For more information on Fluke 3000 FC General Maintenance System talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title