Connect your FC AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Plus, you can connect the t3000 FC Wireless K-Type wireless temperature module and view remote temperature measurements.
You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements.
KEY FEATURES
The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement trouble-shooting:
AC and DC voltage measurements to 1000 V.
AC and DC current with 0.01 mA resolution.
Continuity, resistance, diode test, capacitance and frequency measurements.
MIN/MAX recording.
CAT III 1000 V, Cat IV 600 V; IP54.
The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting:
True-RMS AC clamp meter.
Measure up to 400 AAC.
Use as a standalone meter or as part of the system.
Logging function for recording and saving up to 65,000 readings.
Inrush function.
With the Fluke t3000 FC Wireless K-Type Temperature Module you can:
Use as a standalone meter or as part of the system.
Logging function for recording and saving up to 65,000 readings.
Introducing Fluke Connect
Fluke 3000 FC HVAC Specifications
AC Voltage
Range ¹ / Resolution
600.0 mV / 0.1 mV
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V.
Accuracy 234
45 Hz to 500 Hz
1.0% + 3.
500 Hz to 1 kHz
2.0% + 3.
1. All AC voltage ranges are specified from 1% of range to 100% of range.
2. Crest factor of ? 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
3. For non-sinusoidial waveforms, add +(2% of reading + 2% full scale) typical, for crest factor up to 3.
4. Do not exceed 107 V-Hz.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function
mV
Range / Resolution
600.0 mV / 0.1 mV.
Accuracy
0.09% + 2.
V
Range / Resolution
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1000 V / 1 V.
Accuracy
0.09% + 2
0.15% + 2.
)))
Range / Resolution
600 Ω / 1 Ω
Accuracy
Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer.
Ω
Range / Resolution
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
60.00 kΩ / 0.1 kΩ
600.0 kΩ / 0.001 MΩ
50.00 MΩ / 0.01 MΩ.
Accuracy
0.5% + 2
0.5% + 1
1.5% + 3.
Diode test
Range / Resolution
2.000 V / 0.001 V.
Accuracy
1% + 2.
µF
Range / Resolution
1000 nF / 1 nF
10.00 µF / 0.01 µF
100.0 µF / 0.1 µF
9999 µF1 / 1 µF.
Accuracy
1.2% + 2
10% typical.
1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2% + 2.
AC and DC Current
Function
mA AC
(45 Hz to 1 kHz)
Range 1 / Resolution
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA.
Accuracy
1.5% + 3.
mA DC 2
Range 1 / Resolution
60.00 mA / 0.01 mA
400.0 mA 3/ 0.1 mA.
Accuracy
0.5% + 3.
1. All AC current ranges are specified from 5% of range to 100% of range.
2. Input burden voltage (typical): 400 mA input 2 mV/mA.
3. 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range / Resolution
99.99 Hz / 0.01 Hz
999.9 Hz / 0.1 Hz
9.999 kHz / 0.001 kHz
99.99 kHz / 0.01 kHz.
Accuracy 1
0.1% + 1.
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function
Overload
protection
Input impedance
(nominal)
Common mode rejection ratio (1 kΩ unbalance)
Normal mode rejection
V DC
1100 Vrms
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz.
V AC
1100 Vrms
> 10 MΩ < 100 pF
> 60 dB, DC to 60 Hz
> 60 dB at 50 Hz or 60 Hz.
mA AC/DC
1100 Vrms
> 10 MΩ < 100 pF
> 120 dB at DC, 50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz.
Open circuit test voltage
Full scale voltage
Typical short circuit current.
To 6 MΩ
50 MΩ
Typical short circuit current.
1100 Vrms
< 2.7 VDC
< 0.7 VDC
< 0.9 VDC
< 350 mA.
1100 Vrms
< 2.7 VDC
2.000 VDC
< 1.1 mA.
mA Function
Overload protection
Fused, 44/100 A, 1000 V FAST Fuse.
Overload
600 mA overload for 2 minutes maximum, 10 minutes rest minimum.
MIN/MAX Recording Accuracy
DC functions
The specified accuracy of the measurement function +12 counts for changes > 350 mS in duration.
AC functions
The specified accuracy of the measurement function +40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground
1000 VDC or AC rms.
Ω fuse protection from A inputs
0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only.
Display (LCD)
Update rate
4/sec.
Volts, amps, ohms
6000 counts.
Frequency
10,000 counts.
Capacitance
1,000 counts.
Battery type
Three AA Alkaline batteries, NEDA 15A IEC LR6.
Battery life
250 hours minimum.
RF communications
2.4 GHZ ISM Band.
RF communication range
Open air, unobstructed
Up to 20 m.
Obstructed, sheetrock wall
Up to 6.5 m.
Obstructed, concrete wall, or steel electrical enclosure
Up to 3.5 m.
Temperature
Operating
-10°C to 50°C.
Storage
-40°C to 60°C.
Temperature coefficient
0.1 x (specified accuracy) / °C (< 18°C or > 28°C).
Relative humidity
0% to 90% (0°C to 35°C)
0% to 75% (35°C to 40°C)
0% to 45% (40°C to 50°C).
Altitude
Operating
2,000 m.
Storage
12,000 m.
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008,
FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE.
Safety compliance
ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010.
Certifications
CSA, FCC, CE.
Ingress Protection (IP) rating
IP54.
Pollution Degree
2.
Size (H x W x L)
4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in).
Weight
340 g (12 oz).
Warranty
Three years.
Not compatible with Fluke CNX test tools.
Fluke a3000 FC Wireless AC Current Clamp Module
Specifications
Range
0.5 A to 400.0 A.
Resolution
0.1 A.
Accuracy
400.0 A: 2% +5 digits (10 Hz to 100 Hz) 2.5% +5 digits (100 Hz to 500 Hz).
Inrush
Max displayed reading
999.9A.
Crest factor (50 Hz / 60 Hz)
3 at 500 A
2.5 at 600 A
1.42 at 1000 A
add 2% for C.F. > 2.
LCD w/ backlight
3½ digits.
Log rate/interval
1 sec minimum/adjustable by PC.
Battery type
2 AA, NEDA 15 A, IEC LR6.
Battery life
400 hours.
Memory
Record up to 65,000 readings.
RF communications
2.4 GHZ ISM Band.
RF communication range
Open air, unobstructed
Up to 20 m.
Obstructed, sheetrock wall
Up to 6.5 m.
Obstructed, concrete wall or steel electrical enclosure
Up to 3.5 m.
Operating temperature
-10°C to +50°C.
Storage temperature
-40°C to +60°C.
Temperature coefficient
Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C).
Operating humidity
90% at 35°C
75% at 40°C
45% at 50°C.
Altitude
Operating
2,000 m.
Storage
12,000 m.
EMC
EN 61326-1:2006.
Safety compliance
IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2.
Safety rating
CAT III 600 V.
Certifications
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE.
Ingress Protection (IP) rating
IP30.
Pollution Degree
2.
Jaw opening
34 mm (1.33 in).
Size (H x W x D)
20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in).
Weight
.22 kg (8 oz).
Warranty
Three years.
Not compatible with Fluke CNX test tools.
Fluke t3000 FC Wireless K-Type Temperature Module
General Specifications
Range K-Type
-200°C to 1372°C.
Resolution
0.1°C
Accuracy
+[0.5% + 0.3°C] counts.
Input terminals
K-type mini.
LCD w/backlight
3 ½ digits.
Log rate/interval
1 sec minimum/adjustable by PC.
Battery type
2 AA, NEDA 15 A, IEC LR6.
Battery life
400 hours.
Memory
Record up to 65,000 readings.
RF communications
2.4 GHZ ISM Band.
RF communication range
Open air, unobstructed
Up to 20 m.
Obstructed, sheetrock wall
Up to 6.5 m.
Obstructed, concrete wall or steel electrical enclosure
Up to 3.5 m.
Operating temperature
-10°C to +50°C.
Storage temperature
-40°C to +60°C.
Temperature coefficient
0.01% of reading +0.03°C per°C.
Temperature scale
ITS-90.
Operating humidity
90% at 35°C, 75% at 40°C, 45% at 50°C.
Altitude
Operating
2,000 m.
Storage
12,000 m.
EMC
EN 61326-1:2006.
Safety compliance
IEC 61010-1, CAT I, 3rd edition Pollution Degree 2.
Certifications
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE.
Ingress Protection (IP) rating
IP42.
Pollution Degree
2.
Dimensions (H x W x D)
16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in).
Weight
.22 kg (8 oz).
Fluke 3000 FC HVAC System warranty
Three years.