Find The Needle Add My Company
Fluke 3000 FC HVAC System
Connect your FC AC Wireless Current Clamp Module to your test point, and view the results up to 20 meters away on the FC Wireless Digital Multimeter. Plus, you can connect the t3000 FC Wireless K-Type wireless temperature module and view remote temperature measurements. You’ll save time, with less run-around collecting multiple measurements. Use multiple modules for measurements on three-phase systems, as a stand-alone measurement tool or combine with other Fluke Connect modules as a system for multiple measurements. KEY FEATURES The Fluke 3000 FC Series Wireless Multimeter with the Fluke Connect® app has all the essentials for convenient test and measurement trouble-shooting: AC and DC voltage measurements to 1000 V. AC and DC current with 0.01 mA resolution. Continuity, resistance, diode test, capacitance and frequency measurements. MIN/MAX recording. CAT III 1000 V, Cat IV 600 V; IP54. The Fluke a3000 FC Wireless AC Current Clamp Module has all the essentials for convenient test and measurement troubleshooting: True-RMS AC clamp meter. Measure up to 400 AAC. Use as a standalone meter or as part of the system. Logging function for recording and saving up to 65,000 readings. Inrush function. With the Fluke t3000 FC Wireless K-Type Temperature Module you can: Use as a standalone meter or as part of the system. Logging function for recording and saving up to 65,000 readings. Introducing Fluke Connect Fluke 3000 FC HVAC Specifications AC Voltage Range ¹ / Resolution 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V. Accuracy 234 45 Hz to 500 Hz 1.0% + 3. 500 Hz to 1 kHz 2.0% + 3. 1. All AC voltage ranges are specified from 1% of range to 100% of range. 2. Crest factor of ? 3 at full scale up to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V. 3. For non-sinusoidial waveforms, add +(2% of reading + 2% full scale) typical, for crest factor up to 3. 4. Do not exceed 107 V-Hz. DC Voltage, Continuity, Resistance, Diode Test and Capacitance Function mV Range / Resolution 600.0 mV / 0.1 mV. Accuracy 0.09% + 2. V Range / Resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V. Accuracy 0.09% + 2 0.15% + 2. ))) Range / Resolution 600 Ω / 1 Ω Accuracy Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 µs or longer. Ω Range / Resolution 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 60.00 kΩ / 0.1 kΩ 600.0 kΩ / 0.001 MΩ 50.00 MΩ / 0.01 MΩ. Accuracy 0.5% + 2 0.5% + 1 1.5% + 3. Diode test Range / Resolution 2.000 V / 0.001 V. Accuracy 1% + 2. µF Range / Resolution 1000 nF / 1 nF 10.00 µF / 0.01 µF 100.0 µF / 0.1 µF 9999 µF1 / 1 µF. Accuracy 1.2% + 2 10% typical. 1 In the 9999 µF range for measurements to 1000 µF, the measurement accuracy is 1.2% + 2. AC and DC Current Function mA AC (45 Hz to 1 kHz) Range 1 / Resolution 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA. Accuracy 1.5% + 3. mA DC 2 Range 1 / Resolution 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA. Accuracy 0.5% + 3. 1. All AC current ranges are specified from 5% of range to 100% of range. 2. Input burden voltage (typical): 400 mA input 2 mV/mA. 3. 400.0 mA accuracy specified up to 600 mA overload. Frequency Range / Resolution 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 kHz 99.99 kHz / 0.01 kHz. Accuracy 1 0.1% + 1. 1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps. Input Characteristics Function Overload protection Input impedance (nominal) Common mode rejection ratio (1 kΩ unbalance) Normal mode rejection V DC 1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz. V AC 1100 Vrms > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz > 60 dB at 50 Hz or 60 Hz. mA AC/DC 1100 Vrms > 10 MΩ < 100 pF > 120 dB at DC, 50 Hz or 60 Hz > 60 dB at 50 Hz or 60 Hz. Open circuit test voltage Full scale voltage Typical short circuit current. To 6 MΩ 50 MΩ Typical short circuit current. 1100 Vrms < 2.7 VDC < 0.7 VDC < 0.9 VDC < 350 mA. 1100 Vrms < 2.7 VDC 2.000 VDC < 1.1 mA. mA Function Overload protection Fused, 44/100 A, 1000 V FAST Fuse. Overload 600 mA overload for 2 minutes maximum, 10 minutes rest minimum. MIN/MAX Recording Accuracy DC functions The specified accuracy of the measurement function +12 counts for changes > 350 mS in duration. AC functions The specified accuracy of the measurement function +40 counts for changes > 900 mS in duration. General Specifications Maximum voltage between any terminal and earth ground 1000 VDC or AC rms. Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only. Display (LCD) Update rate 4/sec. Volts, amps, ohms 6000 counts. Frequency 10,000 counts. Capacitance 1,000 counts. Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6. Battery life 250 hours minimum. RF communications 2.4 GHZ ISM Band. RF communication range Open air, unobstructed Up to 20 m. Obstructed, sheetrock wall Up to 6.5 m. Obstructed, concrete wall, or steel electrical enclosure Up to 3.5 m. Temperature Operating -10°C to 50°C. Storage -40°C to 60°C. Temperature coefficient 0.1 x (specified accuracy) / °C (< 18°C or > 28°C). Relative humidity 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C). Altitude Operating 2,000 m. Storage 12,000 m. Electromagnetic compatibility EMI, RFI, EMC, RF EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE. Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010. Certifications CSA, FCC, CE. Ingress Protection (IP) rating IP54. Pollution Degree 2. Size (H x W x L) 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in). Weight 340 g (12 oz). Warranty Three years. Not compatible with Fluke CNX test tools. Fluke a3000 FC Wireless AC Current Clamp Module Specifications Range 0.5 A to 400.0 A. Resolution 0.1 A. Accuracy 400.0 A: 2% +5 digits (10 Hz to 100 Hz) 2.5% +5 digits (100 Hz to 500 Hz). Inrush Max displayed reading 999.9A. Crest factor (50 Hz / 60 Hz) 3 at 500 A 2.5 at 600 A 1.42 at 1000 A add 2% for C.F. > 2. LCD w/ backlight 3½ digits. Log rate/interval 1 sec minimum/adjustable by PC. Battery type 2 AA, NEDA 15 A, IEC LR6. Battery life 400 hours. Memory Record up to 65,000 readings. RF communications 2.4 GHZ ISM Band. RF communication range Open air, unobstructed Up to 20 m. Obstructed, sheetrock wall Up to 6.5 m. Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m. Operating temperature -10°C to +50°C. Storage temperature -40°C to +60°C. Temperature coefficient Add 0.1 x (specified accuracy) / °C (< 18°C or > 28°C). Operating humidity 90% at 35°C 75% at 40°C 45% at 50°C. Altitude Operating 2,000 m. Storage 12,000 m. EMC EN 61326-1:2006. Safety compliance IEC 61010-1, 600 V CAT III, 3rd edition Pollution Degree 2. Safety rating CAT III 600 V. Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE. Ingress Protection (IP) rating IP30. Pollution Degree 2. Jaw opening 34 mm (1.33 in). Size (H x W x D) 20.3 x 7.49 x 3.55 cm (8 x 2.95 x 1.4 in). Weight .22 kg (8 oz). Warranty Three years. Not compatible with Fluke CNX test tools. Fluke t3000 FC Wireless K-Type Temperature Module General Specifications Range K-Type -200°C to 1372°C. Resolution 0.1°C Accuracy +[0.5% + 0.3°C] counts. Input terminals K-type mini. LCD w/backlight 3 ½ digits. Log rate/interval 1 sec minimum/adjustable by PC. Battery type 2 AA, NEDA 15 A, IEC LR6. Battery life 400 hours. Memory Record up to 65,000 readings. RF communications 2.4 GHZ ISM Band. RF communication range Open air, unobstructed Up to 20 m. Obstructed, sheetrock wall Up to 6.5 m. Obstructed, concrete wall or steel electrical enclosure Up to 3.5 m. Operating temperature -10°C to +50°C. Storage temperature -40°C to +60°C. Temperature coefficient 0.01% of reading +0.03°C per°C. Temperature scale ITS-90. Operating humidity 90% at 35°C, 75% at 40°C, 45% at 50°C. Altitude Operating 2,000 m. Storage 12,000 m. EMC EN 61326-1:2006. Safety compliance IEC 61010-1, CAT I, 3rd edition Pollution Degree 2. Certifications CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE. Ingress Protection (IP) rating IP42. Pollution Degree 2. Dimensions (H x W x D) 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in). Weight .22 kg (8 oz). Fluke 3000 FC HVAC System warranty Three years. Not compatible with Fluke CNX test tools.

For more information on Fluke 3000 FC HVAC System talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title