Find The Needle Add My Company
Fluke 353 True-rms 2000 A Clamp Meter
Confidently take reliable readings with the True-rms, Fluke 353 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. FEATURES Reliably handle a wide range of high-current applications with 2000 A AC + DC true-rms, 1400 A ac, and 2000 A DC. The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors. CAT IV 600 V, CAT III 1000 V rating for added user protection. In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability. Accurately measure frequency up to 1 kHz for optimum troubleshooting. Quickly analyze readings using the MIN, MAX, and AVG functions. A large backlit display allows for easy visibility in low-lit areas. Use the display hold feature to capture readings even when the display cannot be viewed. Use the low-pass filter to smooth out noisy loads and stabilize readings. Fluke 353 Specifications Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC RMS. Resolution 10 mA / 100 mA / 1 A. Accuracy A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits. Trigger level for Inrush 0.50 A / 5.0 A / 5 A. Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A. Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A. Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC RMS. Crest Factor1 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A. Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC RMS. Resolution 10 mA / 100 mA / 1 A. Accuracy 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits. Trigger level for Inrush 0.50 A / 5.0 A / 5 A. Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A. Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A. Frequency measurement Measurement range 5.0 Hz to 1 kHz. Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz). Accuracy - 5.0 Hz to 100 Hz 0.2% + 2 counts. Accuracy - 100.1 Hz to 1 kHz 0.5% + 5 counts. Trigger level Refer to current and voltage tables. 1. Add 2% to error spec for CF > 2 General Specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6. Battery life (with typical usage, backlight off) 100 hours. Test leads Rated to 1000 V. Weight .814 kg (1.8 lb). Jaw size 58 mm (2.28 in). Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in). Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III. Environmental Specifications Operating temperature 32°F to +122°F (0°C to +50°C). Storage temperature -4°F to 140°F (-20°C to +60°C). Operating humidity 0 to 95% (non-condensing). Operating altitude 2000 m. Storage altitude 10,000 m. IP rating 42 (indoor use only). Drop test requirements 1 m. EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325. Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C. Voltage 0.1% of reading per °C outside 22°C to 24°C.

For more information on Fluke 353 True-rms 2000 A Clamp Meter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title