Find The Needle Add My Company
Fluke 355 True-rms 2000 A Clamp Meter
Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter; the tool of choice for high current clamp-on amp meter measurement up to 2000 A. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians. FEATURES Reliably handle a wide range of high-current applications with 2000 A AC + DC True RMS, 1400 A AC, and 2000 A DC. The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors. CAT IV 600 V, CAT III 1000 V rating for added user protection. In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability. High voltage measurement of 1000 V AC + DC True RMS, 600 V AC, and 1000 V DC allows the user to perform multiple tests with only one tool. Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. Accurately measure frequency up to 1 kHz for optimum troubleshooting. Quickly analyze readings using the MIN, MAX, and AVG functions. A large backlit display allows for easy visibility in low-lit areas. Use the display hold feature to capture readings even when the display cannot be viewed. Use the low-pass filter to smooth out noisy loads and stabilize readings. Fluke 355 Specifications Electrical Specifications Current measurement DC and AC 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A / 1400 AC rms. Resolution 10 mA / 100 mA / 1 A. Accuracy A: 1.5% rdg + 15 digits A: 1.5% rdg + 5 digits. Trigger level for Inrush 0.50 A / 5.0 A / 5 A. Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A. Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A. Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A / 1400 AC rms. Crest Factor1 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A. Current measurement AC 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 AC rms. Resolution 10 mA / 100 mA / 1 A. Accuracy 10 A: 3.5% rdg + 15 digits 10 A: 3.5% rdg + 5 digits. Trigger level for Inrush 0.50 A / 5.0 A / 5 A. Trigger level for Hz filter OFF 2.50 A / 2.5 A / 8 A. Trigger level for Hz filter ON 0.50 A / 2.5 A / 8 A. Voltage measurement DC and AC 10 Hz to 100 Hz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) Range 4 V / 40 V / 400 V / 600 V AC rms / 1000 VDC. Resolution 1 mV / 10 mV / 100 mV / 1 V. Accuracy 1% rdg + 10 digits 1% rdg + 5 digits. Trigger level for Hz filter OFF 0.25 V / 6 V. Trigger level for Hz filter ON 0.25 V / 6 V. Voltage measurement AC 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10% over range to 660 V and 1100 V respectively.) Range 4 V / 40 V / 400 V / 600 V ac rms. Resolution 1 mV / 10 mV / 100 mV / 1 V. Accuracy 3% rdg + 10 digits 3% rdg + 5 digits. Trigger level for Hz filter OFF 0.050 V / 0.25 V / 6 V. Trigger level for Hz filter ON 0.050 V / 0.25 V / 6 V. Ohms measurement Range 4 kΩ / 40 kΩ / 400 kΩ. Resolution 0.1 Ω / 1 Ω / 10 Ω / 100 Ω. Accuracy 1.5% + 5 digits. Continuity beeper On at ? 30 Ω Off at ? 100 Ω. Frequency measurement Measurement range 5.0 Hz to 1 kHz. Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz). Accuracy - 5.0 Hz to 100 Hz 0.2% + 2 counts. Accuracy - 100.1 Hz to 1 kHz 0.5% + 5 counts. Trigger level Refer to current and voltage tables. 1. Add 2% to error spec for CF > 2 General Specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6. Battery life (with typical usage, backlight off) 100 hours. Test leads Rated to 1000 V. Weight .814 kg (1.8 lb). Jaw size 58 mm (2.28 in). Dimensions (L x W x D) 300 x 98 x 52 mm (12 x 3.75 x 2 in). Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III. Environmental Specifications Operating temperature 32°F to +122°F (0°C to +50°C). Storage temperature -4°F to 140°F (-20°C to +60°C). Operating humidity 0 to 95% (non-condensing). Operating altitude 2000 m. Storage altitude 10,000 m. IP rating 42 (indoor use only). Drop test requirements 1 m. EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325. Temperature coefficients Current 0.1% of reading per °C outside 22°C to 24°C. Voltage 0.1% of reading per °C outside 22°C to 24°C. Fluke 355 warranty 2 years.

For more information on Fluke 355 True-rms 2000 A Clamp Meter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title