Sign In
The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line.
The Fluke 369 FC has an oversize 61 mm jaw for work with extra-large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimise external electromagnetic interference.
The 369 FC also offers wireless data connectivity via Fluke Connect. As part of Fluke Connect® - the industry’s largest system of software and more than 40 wireless test tools - the 369 FC allows you to track changes in leakage current over time, helping to identify potential problems before they turn into major failures.
FEATURES
True-rms measurements for accuracy when measuring complex, non-sinusoidal waveforms.
61 mm jaw opening.
Highest resolution of 1 µA, measure up to 60 A.
Selectable filter function removes unwanted noise.
Max/Min/Average readings and hold function.
Forward-facing LED worklight for use in dark wiring cabinets.
Backlit display; auto backlight off and auto power off for extended battery life.
CAT III 600V safety rating.
Internal Memory Logging: up to 65,000 measurement points.
Fluke 369 FC Specifications
Measurement Function
AC (alternating current).
AC Current Range(s)
3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A.
mA/A: manual selection
3 mA/30 mA/300 mA: automatic selection
3 A/30 A/60 A: automatic selection.
Range/Resolution
3 mA¹/0.001 mA.
30 mA/0.01 mA.
300 mA/0.1 mA.
3 A/0.001 A.
30 A/0.01 A.
60 A/0.1 A.
Accuracy - Filter Activated (40 to 70Hz), Filter Off (40 to 1kHz)
3 mA to 30 A: +1% + 5 digits.
60 A: 2% + 5 digits.
Frequency
40 Hz to 1 kHz.
Crest Factor
3.
¹The minimum value is 10 µA rms.
General Specifications
Display (LCD)
Digital readout: 3300 count.
Display Refresh Rate
4 times/sec.
Maximum Conductor Diameter
61 mm.
Battery
2AA, IEC LR6, NEDA 15A, alkaline.
Battery Life
More than 150 hours (without backlight and spotlight).
Automatic Shutdown
Meter automatically shuts down after 15 minutes of inactivity.
Safety and Environmental Specifications
General Safety
IEC 61010-1: Pollution Degree 2.
Measurement Safety
IEC 61010-2-032: CAT III 600V, CAT IV 300V.
Operating Temperature
-10 to +50°C.
Storage Temperature
-40 to +60°C.
Operating Humidity
Non-condensing (<10°C).
90% relative humidity (10 to 30°C).
75% relative humidity (30 to 40°C).
45% relative humidity (40 to 50°C).
Protection Class
IEC 61557-13: Class 2, ?30A/m.
Dimensions
257 x 116 x 46 mm.
Weight
600 g.
Fluke 369 FC warranty
3 years.
For more information on Fluke 369 FC True-rms Leakage Current Clamp Meter talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.