Find The Needle Add My Company
Fluke 374 FC True-rms AC/DC Clamp Meter
The Fluke 374 FC Wireless True-rms AC/DC Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 374 can read up to 600 V and 600 A in both ac and dc modes. The Fluke Connect® enabled 374 FC Clamp Meter logs measurements to pinpoint intermittent faults precisely without the need for the technician to be present. Those measurements are then wirelessly transmitted to the Fluke Connect app on smartphones or tablets and automatically uploaded to the cloud, keeping technicians outside the arc flash zone and away from dangerous moving machinery, thus improving safety. FEATURES: Connect your meter to your smartphone with Fluke Connect Measurements. Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks. Record results directly to your phone and the Cloud. Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls. Compatible with TPAK magnetic hanging strap. Proprietary inrush measurement technology to filter out noise and capture motor starting current. CAT IV 600 V, CAT III 1000 V safety rating. Three-year warranty. Soft carrying case. MEASUREMENT CAPABILITIES: 600 A ac and dc current measurement. 2500 A ac current measurement with (optional) iFlex flexible current probe. 1000 V ac and dc voltage measurement. True-rms voltage and current for accurate measurements on non-linear signals. Resistance measurement to 6000 Ω with continuity detection. Min, max, average, and inrush recording to capture variations automatically. 1000 µF capacitance measurement. Fluke 374 Specifications AC Current Via Jaws Range 600.0 A. Resolution 0.1 A. Accuracy 2% +5 digits (10 Hz to 100 Hz) 2.5% +5 digits (100-500 Hz). Crest Factor (50/60 Hz) 2.5 @ 600 A Add 2% for C.F. >2. AC Current via Flexible Current Probe Range 2500 A. Resolution 0.1 A (? 600 A) 1 A (? 2500 A). Accuracy 3% +5 digits (5 - 500 Hz). Crest Factor (50/60Hz) 2.5 at 1400 A 1.42 at 2500 A Add 2% for C.F. > 2. DC Current Range 600.0 A. Resolution 0.1 A. Accuracy 2% +5 digits. AC Voltage Range 1000 V. Resolution 0.1 V (?600.0 V) 1 V (?1000 V). Accuracy 1.5% +5 digits (20 Hz to 500 Hz). DC Voltage Range 1000 V. Resolution 0.1 V (?600.0 V) 1 V (?1000 V). Accuracy 1% +5 digits. mV DC Range 500.0 mV. Resolution 0.1 mV. Accuracy 1% +5 digits. Resistance Range 6000 Ω. Resolution 0.1 Ω (?600 Ω) 1 Ω (?6000 Ω). Accuracy 1% +5 digits. Capacitance Range 1000 µF. Resolution 0.1 µF (? 100 µF) 1 µ F (? 1000 µF). Accuracy 1% +4 digits. Mechanical Specifications Maximum voltage between any terminal and earth ground 1000 V. Batteries 2 AA, NEDA 15A, IEC LR6. Operating Temperature -10 °C to +50 °C. Storage Temp -40 °C to +60 °C. Operating Humidity Non condensing (< 10 °C) ? 90 % RH (at 10 °C to 30 °C) ? 75 % RH (at 30 °C to 40 °C) ? 45 % RH (at 40 °C to 50 °C). Operating Altitude 3000 meters. Storage Altitude 12,000 meters. Dimensions 249 x 85 x 45 mm. Weight 395 g Jaw Opening 34 mm. Flexible current probe diameter 7.5 mm. Flexible current probe cable length (head to electronics connector) 1.8 m. Safety IEC 61010-1, Pollution Degree 2 IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V. IP Rating IEC 60529: IP30, non-operating. Radio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLE. Fluke 374 FC warranty 3 years.

For more information on Fluke 374 FC True-rms AC/DC Clamp Meter talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title