Sign In
The Fluke 374 FC Wireless True-rms AC/DC Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 374 can read up to 600 V and 600 A in both ac and dc modes.
The Fluke Connect® enabled 374 FC Clamp Meter logs measurements to pinpoint intermittent faults precisely without the need for the technician to be present. Those measurements are then wirelessly transmitted to the Fluke Connect app on smartphones or tablets and automatically uploaded to the cloud, keeping technicians outside the arc flash zone and away from dangerous moving machinery, thus improving safety.
FEATURES:
Connect your meter to your smartphone with Fluke Connect Measurements.
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks.
Record results directly to your phone and the Cloud.
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls.
Compatible with TPAK magnetic hanging strap.
Proprietary inrush measurement technology to filter out noise and capture motor starting current.
CAT IV 600 V, CAT III 1000 V safety rating.
Three-year warranty.
Soft carrying case.
MEASUREMENT CAPABILITIES:
600 A ac and dc current measurement.
2500 A ac current measurement with (optional) iFlex flexible current probe.
1000 V ac and dc voltage measurement.
True-rms voltage and current for accurate measurements on non-linear signals.
Resistance measurement to 6000 Ω with continuity detection.
Min, max, average, and inrush recording to capture variations automatically.
1000 µF capacitance measurement.
Fluke 374 Specifications
AC Current Via Jaws
Range
600.0 A.
Resolution
0.1 A.
Accuracy
2% +5 digits (10 Hz to 100 Hz)
2.5% +5 digits (100-500 Hz).
Crest Factor (50/60 Hz)
2.5 @ 600 A
Add 2% for C.F. >2.
AC Current via Flexible Current Probe
Range
2500 A.
Resolution
0.1 A (? 600 A)
1 A (? 2500 A).
Accuracy
3% +5 digits (5 - 500 Hz).
Crest Factor (50/60Hz)
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2.
DC Current
Range
600.0 A.
Resolution
0.1 A.
Accuracy
2% +5 digits.
AC Voltage
Range
1000 V.
Resolution
0.1 V (?600.0 V)
1 V (?1000 V).
Accuracy
1.5% +5 digits (20 Hz to 500 Hz).
DC Voltage
Range
1000 V.
Resolution
0.1 V (?600.0 V)
1 V (?1000 V).
Accuracy
1% +5 digits.
mV DC
Range
500.0 mV.
Resolution
0.1 mV.
Accuracy
1% +5 digits.
Resistance
Range
6000 Ω.
Resolution
0.1 Ω (?600 Ω)
1 Ω (?6000 Ω).
Accuracy
1% +5 digits.
Capacitance
Range
1000 µF.
Resolution
0.1 µF (? 100 µF)
1 µ F (? 1000 µF).
Accuracy
1% +4 digits.
Mechanical Specifications
Maximum voltage between any terminal and earth ground
1000 V.
Batteries
2 AA, NEDA 15A, IEC LR6.
Operating Temperature
-10 °C to +50 °C.
Storage Temp
-40 °C to +60 °C.
Operating Humidity
Non condensing (< 10 °C)
? 90 % RH (at 10 °C to 30 °C)
? 75 % RH (at 30 °C to 40 °C)
? 45 % RH (at 40 °C to 50 °C).
Operating Altitude
3000 meters.
Storage Altitude
12,000 meters.
Dimensions
249 x 85 x 45 mm.
Weight
395 g
Jaw Opening
34 mm.
Flexible current probe diameter
7.5 mm.
Flexible current probe cable length
(head to electronics connector)
1.8 m.
Safety
IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V.
IP Rating
IEC 60529: IP30, non-operating.
Radio Frequency Certification FCC ID
T68-FBLE IC:6627A-FBLE.
Fluke 374 FC warranty
3 years.
For more information on Fluke 374 FC True-rms AC/DC Clamp Meter talk to Cuthbertson Laird Group