The Fluke 376 FC Wireless True-rms AC/DC Clamp Meter offers improved performance perfect for a wide range of current measurement situations. With true-rms voltage and current measurements, the Fluke 376 can read up to 1000 V and 1000 A in both ac and dc modes.
The Fluke Connect® enabled 376 FC Clamp Meter logs measurements to pinpoint intermittent faults precisely without the need for the technician to be present. Those measurements are then wirelessly transmitted to the Fluke Connect app on smartphones or tablets and automatically uploaded to the cloud, keeping technicians outside the arc flash zone and away from dangerous moving machinery, thus improving safety.
Additionally, the Fluke 376 FC includes the iFlex flexible current probe, which expands the measurement range to 2500 A ac while providing increased display flexibility, ability to measure around awkward sized conductors and improved wire access. The iFlex probe fits neatly into the bottom of the unit and is an ideal product for bending around conductors that simply aren't possible to test using a conventional clamping system.
FEATURES:
Connect your meter to your smartphone with Fluke Connect Measurements.
Read measurements on your phone at a safe distance, wearing less PPE while your meter takes all the risks.
Record results directly to your phone and the Cloud.
Capture intermittent faults while performing other tasks.
Create and share reports from the field via email, or converse in real-time with ShareLive™ video calls.
iFlex flexible current probe expands the measurement range to 2500 A ac; provides access to large conductors in tight spaces.
TPAK magnetic hanging strap.
Integrated VFD low pass filter for accurate motor drive measurements.
Proprietary inrush measurement technology to filter out noise and capture motor starting current.
CAT IV 600 V, CAT III 1000 V safety rating.
Three-year warranty.
Fluke 376 FC Specifications
AC Current Via Jaws
Range
999.9 A.
Resolution
0.1 A.
Accuracy
2% +5 digits (10 Hz to 100 Hz)
2.5% +5 digits (100-500 Hz).
Crest Factor (50/60 Hz)
3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2.
AC Current via Flexible Current Probe
Range
2500 A.
Resolution
0.1 A (? 600 A)
1 A (? 2500 A).
Accuracy
3% +5 digits (5 - 500 Hz).
Crest Factor (50/60Hz)
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2.
DC Current
Range
600.0 A.
Resolution
0.1 A.
Accuracy
2% +5 digits.
AC Voltage
Range
1000 V.
Resolution
0.1 V (?600.0 V)
1 V (?1000 V).
Accuracy
1.5% +5 digits (20 Hz to 500 Hz).
DC Voltage
Range
1000 V.
Resolution
0.1 V (?600.0 V)
1 V (?1000 V).
Accuracy
1% +5 digits.
mV DC
Range
500.0 mV.
Resolution
0.1 mV.
Accuracy
1% +5 digits.
Frequency Via Jaw
Range
5.0 Hz to 500.0 Hz.
Resolution
0.1 Hz.
Accuracy
0.5% +5 digits.
Trigger Level
5 Hz to 10 Hz, ?10 A
10 Hz to 100 Hz, ?5 A
100 Hz to 500 Hz, ?10 A.
Frequency via Flexible Current Probe
Range
5.0 Hz to 500.0 Hz.
Resolution
0.1 Hz.
Accuracy
0.5% +5 digits.
Trigger Level
5 Hz to 20 Hz, ?25 A
20 Hz to 100 Hz, ?20 A
100 Hz to 500 Hz, ?25 A.
Resistance
Range
60 kΩ.
Resolution
0.1 Ω (?600 Ω)
1 Ω (?6000 Ω)
10 Ω (?60 kΩ).
Accuracy
1% +5 digits.
Capacitance
Range
1000 µF.
Resolution
0.1 µF (? 100 µF)
1 µ F (? 1000 µF).
Accuracy
1% +4 digits.
Mechanical Specifications
Maximum voltage between any terminal and earth ground
1000 V.
Batteries
2 AA, NEDA 15A, IEC LR6.
Operating Temperature
-10 °C to +50 °C.
Storage Temp
-40 °C to +60 °C.
Operating Humidity
Non condensing (< 10 °C)
? 90 % RH (at 10 °C to 30 °C)
? 75 % RH (at 30 °C to 40 °C)
? 45 % RH (at 40 °C to 50 °C).
Operating Altitude
3000 meters.
Storage Altitude
12,000 meters.
Dimensions
249 x 85 x 45 mm.
Weight
395 g
Jaw Opening
34 mm.
Flexible current probe diameter
7.5 mm.
Flexible current probe cable length
(head to electronics connector)
1.8 m.
Safety
IEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V.
IP Rating
IEC 60529: IP30, non-operating.
Radio Frequency Certification FCC ID
T68-FBLE IC:6627A-FBLE.
Fluke 376 FC warranty
3 years.