Sign In
The Fluke 377 FC true-rms clamp meter uses FieldSense™ technology to make testing faster and safer, all without contacting a live conductor. You get accurate voltage and current measurements through the clamp jaw. Simply clip the black test lead to any electrical ground, put the clamp jaw around the conductor and see reliable, accurate voltage and current values on the display.
Measure extremely high current with iFlex® probe
The included iFlex flexible current probe lets you measure ac current as high as 2500 A. Crowded wiring cabinets and large conductors are easily measured with the iFlex probe.
Easy to see, easy to use with included tools
Your job will get easier when you use the 378 FC clamp meter. The display turns green when a stable FieldSense measurement is detected. Visual Continuity also provides a bright green screen for easy detection of continuity in noisy work areas.
Record, analyse, share results with Fluke Connect® software
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows you to gather data as the basis for a preventive maintenance program.
FEATURES
Measure voltage and current with your clamp jaw.
Faster, safer testing - all without touching a live wire - using FieldSense™ technology.
Complete 3-phase voltage and current tests in 3 quick steps.
Fluke 377 FC / 378 FC Clamp Meter Product Video
Fluke 377 FC Clamp Meter Specifications
General Specifications
General Maximum Voltage between any Terminal and Earth Ground
1000 V
Battery
Type
2 AA IEC LR6 alkaline
Life
200 hour
Display
Dual readout
Automatic Power Off
20 minutes
Electrical
AC Current: Jaw
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % +5 digits (10 Hz to 100 Hz)
2.5 % +5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)
3 @ 500 A
2.5 @ 600 A
1.42 @ 1000 A
Add 2 % for C.F. >2
AC Current: Flexible Current Probe
Range
2500 A
Resolution
1 A (?2500 A) 0.1 A (?999.9 A)
Accuracy
3 % +5 digits (5 Hz to 500 Hz)
Crest Factor (50/60Hz)
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2 % for C.F. >2
Position Sensitivity
A
0.5 in (12.7 mm)
1.4 in (35.6 mm)
+ 0.5 %
B
0.8 in (20.3 mm)
2.0 in (50.8 mm)
+ 1.0 %
C
1.4 in (35.6 mm)
2.5 in (63.5 mm)
+ 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range
999.9 A
Resolution
0.1 A
Accuracy
2 % +5 digits1
[1]When using the ZERO function to compensate for offsets.
AC Voltage: Field Sense
Range
1000 V
Resolution
1 V (?1000V)
Accuracy
?4/0 AWG
3 % +5 digits (45 Hz to 66 Hz)
?4/0 AWG
5 % +5 digits (45 Hz to 66 Hz)
AC Voltage: Test Leads
Range
600.0 V 1000 V.
Resolution
0.1 V (?600.0 V)
1 V (?1000 V).
Accuracy
1 % +5 digits (20 Hz to 500 Hz).
DC Voltage
Range
600.0 V
1000 V.
Resolution
0.1 V (?600.0 V)
1 V (?1000 V).
Accuracy
1 % +5 digits.
mV DC
Range
500.0 mV.
Resolution
0.1 mV.
Accuracy
1 % +5 digits.
Amps Frequency: Jaw
Range
5.0 Hz to 500.0 Hz.
Resolution
0.1 Hz.
Accuracy
0.5 % +5 digits.
Trigger Level
5 Hz to 10 Hz, ?10 A
10 Hz to 100 Hz, ? 5 A
100 Hz to 500 Hz, ? 10 A.
Amps Frequency: Flexible Current Probe
Range
5.0 Hz to 500.0 Hz.
Resolution
0.1 Hz.
Accuracy
0.5 % +5 digits.
Trigger Level
5 Hz to 20 Hz, ?25 A
20 Hz to 100 Hz, ?20 A
100 Hz to 500 Hz,?25 A.
Resistance
Range
60.00 kΩ
6000 Ω
600.0 Ω.
Resolution
0.1 Ω (?600.0 Ω)
1 Ω (?6000 Ω)
10 Ω (?60.00 kΩ).
Accuracy
1 % +5 digits.
Capacitance
Range
1000 µF.
Resolution
0.1 µF (?100.0 µF)
1 µF (?1000 µF).
Accuracy
1 % +4 digits.
Mechanical
Size (L x W x H)
274 mm x 86 mm x 47 mm.
Weight (with Batteries)
463 g.
Jaw Opening
34 mm.
Flexible Current Probe Diameter
7.5 mm.
Flexible Current Probe Cable Length (head to electronics connector)
1.8 m.
Rogowski Coil Length
450 mm.
Environmental
Operating Temperature
-10 °C to 50 °C.
Storage Temperature
-40 °C to 60 °C.
Operating Humidity (without condensation)
Non condensing (<10 °C)
?90 % RH (10 °C to 30 °C)
?75 % RH (30 °C to 40 °C)
?45 % RH (40 °C to 50 °C).
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C >28 °C or <18 °C.
Ingress Protection
IEC 60529: IP30 (jaw closed).
Operating Altitude
2000 m.
Storage Altitude
12 000 m.
Electromagnetic Compatibility (EMC)
International
IEC 61326-1: Portable Electromagnetic Environment
IEC 61326-2-2, CISPR 11: Group 1, Class B.
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class B: Equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes.
Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)
Class A equipment (Industrial Broadcast & Communications Equipment).
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)
47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
General
IEC 61010-1: Pollution degree 2.
Measurement
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V.
Current Clamp for Leakage Current Measurements
IEC 61557-13: Class 2, ?30 A/m.
Wireless Radio
Radio Frequency Certification
FCC ID: T68-FBLE IC:6627A-FBLE.
Frequency Range
2405 MHz to 2480 MHz.
Output Power
<100 mW.
For more information on Fluke 377 FC True-rms AC/DC Clamp Meter with iFlex talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.