Sign In
The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is the one product you can use in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex rated areas all around the globe.
With a straight-forward user interface and soft-key menus, the Fluke 568 Ex makes even complex measurements easy. Quickly navigate and adjust emissivity, save data or turn on and off alarms, with just a few pushes of a button. All in a single intrinsically safe tool certified by major rating bodies from around the world.
FEATURES:
Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments.
Conductive Case for carrying the IR thermometer safely into hazardous area.
Easily access advanced features with the soft-key buttons and graphical display.
Measure small objects from further away, with a distance-to-spot ratio of 50:1.
Compatible with mini-connector K-type thermocouple (KTC) probe.
Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table.
Capture up to 99 points of data.
Confidently troubleshoot equipment with +1% measurement accuracy.
Versatile interface with five languages from which to choose.
Fluke 568 Ex Specifications
Infrared Temperature Range
-40 °C to 800 °C (-40 °F to 1472 °F).
Infrared Accuracy
< 0 °C (32 °F): + (1.0 °C (+ 2.0 °F) + 0.1°/1 °C or °F)
> 0 °C (32 °F): + 1 % or + 1.0 °C (+ 2.0 °F), whichever is greater.
Display Resolution
0.1 °C / 0.1 °F.
Infrared Spectral Response
8 µm to 14 µm.
Infrared Response Time
< 500 ms.
Thermocouple Type-K Input Temperature Range
-270 °C to 1372 °C (-454 °F to 2501 °F).
Thermocouple Type-K Input Accuracy
<-40 °C: +(1 °C + 0.2 °/1 °C)
?-40 °C: +1 % or 1 °C, whichever is greater <-40 °F: +(2 °F + 0.2 °/1 °F)
?-40 °F: +1 % or 2 °F, whichever is greater.
D:S (Distance to Measurement Spot Size
50:1.
Laser Sighting
Single-Point Laser.
Minimum Spot Size
19 mm (0.75 in).
Emissivity Adjustment
By Built-in Table of Common Materials or Digitally Adjustable from 0.10 to 1.00 by 0.01.
Data Storage
99 Points.
Hi/Low Alarms
Audible and two-colour visual.
MIN/MAX/AVG/DIFF
Display
Dot matrix with function menus.
Backlight
Two Levels, Normal and Extra Bright for Darkened Environments.
Trigger Lock
Switchable Celsius and Fahrenheit
Power
2 AAA/LR03 type-approved batteries.
Battery Life
4 hours with laser and backlight on
100 hours with laser and backlight off, at 100 % duty cycle.
Operating Temperature
0 to 50°C (32°F to 122°F).
Storage Temperature
-20 °C to 60 °C (-40 °F to 140 °F).
Bead Thermocouple Type K Range
-40 to 260°C (-40 to 500°F).
Bead Thermocouple Type K Accuracy
+ 1.1 °C (2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F)
typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F).
Dimensions
17.69 cm (6.965 in) H x 16.36 cm (6.441 in) L x 5.18 cm (2.039 in).
Weight
0.322 kg (0.7099 lb).
Fluke 568 Ex warranty
2 years.
Safety Certifications
Agency
Safety Rating
ATEX/ IECE
Zone 1 and 2
IECEx EPS 13.0006X
Ex ia IIC T4 Gb
0°C ? Ta ? 50°C
EPS 13 ATEX 1.525 X
II 2G Ex ia IIC T4 Gb.
NEC-500 / NEC-505
Class I Division 1 and 2
Class I, Division 1, Groups ABCD T4
Class I, Division 2, Groups ABCD T4
Class I, Zone 1, AEx ia IIC T4
Ex ia IIC T4
0°C ? Ta ? 50°C.
GOST
Zone 1 and 2
POCC DE.??05.B
Ex ia IIC T4 Gb X
?? 0°C ?? +50°C
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ? Ta ? 50°C.
PCEC
Zone 1 and 2
PCEC
Ex ia IIC T4 Gb
CE13.
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ? Ta ? 50°C.
INMETRO
Zone 1 and 2
IEx 13.0122X
Ex ia IIC T4 Gb
EPS 13 ATEX 1 525 X
II 2G Ex ia IIC T4 Gb
0°C ? Ta ? 50°C.
For more information on Fluke 568 Ex Intrinsically Safe Infrared Thermometer talk to Cuthbertson Laird Group