The Fluke 572-2 Infrared Thermometer is for non-contact temperature measurement. The 572-2 determines the surface temperature of an object by measuring the amount of infrared energy radiated by the object surface. The 572-2 also uses a K-type thermocouple for contact temperature measurement.
The Fluke 572-2 is the one product you can use in high-temperature industrial environments all around the world. Whether you work in power utility, metal refining and smelting, glass, cement or petrochemical environments, the 572-2 allows you to carry the most trusted name in test tools anywhere you need accurate, high-temperature and high distance-to-spot measurements.
FEATURES
Dual laser sighting.
Backlit display.
Current Temperature plus MAX, MIN, DIF, AVG temperature displays.
Adjustable emissivity and predefined emissivity table.
Infrared and thermocouple temperature display.
Celsius or Fahrenheit temperature display.
Standard miniature K-type thermocouple connector input.
Last reading Hold (20 seconds).
Multi-language interface.
High and low temperature alarm.
Data storage and review.
Trigger lock.
Auto off.
Fluke 572-2 Specifications
Infrared Measurements
Infrared temperature range
-30°C to 900°C (-22°F to 1652°F).
IR accuracy (calibration geometry with ambient temperature 23°C + 2°C)
? 0°C: + 1°C or + 1% of the reading, whichever is greater.
? -10°C to < 0°C: +2°C.
< -10°C: +3°C.
? 32°F: + 2°F or + 1% of the reading, whichever is greater.
? 14°F to < 32°F: +4°F.
< 14°F: +6°F.
IR repeatability
+0.5% of reading or +0.5°C (+1°F), whichever is greater.
Display resolution
0.1°C / 0.1°F.
Distance: Spot
60:1 (calculated at 90% energy).
Minimum spot size
19 mm.
Laser sighting
Offset dual laser, output < 1 mW.
Spectral response
8 µm to 14 µm.
Response time (95%)
< 500 ms.
Emissivity
Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials.
Contact Measurements
K-type thermocouple input temperature range
-270°C to 1372°C (-454°F to 2501°F).
K-type thermocouple input accuracy (with ambient temperature 23°C + 2°C)
< -40°C: +(1°C + 0.2° / 1°C).
? -40°C: +1% or 1°C, whichever is greater.
< -40°F: +(2°F + 0.2° / 1°F).
? -40°F: +1% or 2°F, whichever is greater.
K-type thermocouple
0.1°C / 0.1°F.
K-type thermocouple repeatability
+0.5% of reading or +0.5°C (+1°F), whichever is greater.
Measurement Options
Hi/Low alarms
Audible and two-colour visual.
Min/Max/Avg/Dif
Yes.
Switchable celsius and fahrenheit
Yes.
Backlight
Two levels, normal and extra bright for darker environments.
Probe input
K-type thermocouple simultaneous display of probe and IR temperature.
Trigger lock
Yes.
Data storage
99 points.
Display
Dot matrix 98 x 96 pixels with function menus.
Communication
USB 2.0.
K-Type Thermocouple Specifications
Measurement range (bead probe)
-40°C to 260°C (-40°F to 500°F).
Accuracy
+1.1°C (+2.0°F) from 0°C to 260°C (32°F to 500°F). Typically within 1.1°C (2.0°F) from -40°C to 0°C (-40°F to 32°F).
Cable length
1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination.
General Specifications
Safety and compliance
IEC 60825-1
FDA Laser Class II
IEC 61326-1
CE Complaint
CMC # 01120009.
Operating temperature
0°C to 50°C (32°F to 122°F).
Storage temperature
-20°C to 60°C (-4°F to 140°F).
Relative humidity
10% to 90% RH non-condensing up to 30°C (86°F).
Operating altitude
2000 meters above mean sea level.
Weight
0.322 kg (0.7099 lb).
Power
2 AA batteries.
Battery life
8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100% duty cycle (thermometer continuously on).