The Fluke 6500-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6500-2 is designed to enable you to work faster without compromising test results.
With a full QWERTY keyboard, alphanumeric data entry is faster, easier and more convenient. The integral site, location and description codes further speed up data entry on site, and contribute to more efficient testing and results management.
The 6500-2 stores in excess of 1000 test results in its main memory. These can be written to the USB drive for back-up. Data can be sent to the office for generating customer reports while the instrument continues with a cleared memory in the field.
FEATURES
Dedicated key for each test for ‘one-touch’ testing.
Pre-set pass/fail levels to save time.
Single mains socket for appliance connection.
Separate IEC socket for easy mains/extension lead testing.
USB port for data transfer.
Integral QWERTY keyboard for rapid data entry.
Pre-set, auto-test sequences for user convenience.
Integral site, location and description codes for faster data processing.
Fluke 6500-2 Specifications
Test Specifications
The accuracy specification for the display range is defined as +(%reading + digit counts) at 23 °C +5 °C, ?75 % RH.
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C.
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2.
Power-on Test
The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
Display Range
90 V to 264 V.
Accuracy at 50 Hz
+ (2% + 3 counts).
Resolution
0.1 V.
Input Impedance
> 1 MΩ // 2.2 nF.
Maximum Input Mains Voltage
264 V.
Earth Bond Test (Rpe)
Display Range
0 to 19.99 Ω.
Accuracy (After Bond Test Zeroing)
+ (2.5% + 4 counts).
Resolution
0.01 Ω.
Test Current
200 mA AC -0% +40% into 1.99 Ω
25 A AC + 20% into 25 mΩ at 230 V.
Open Circuit Voltage
> 4 V AC, < 24 V AC.
Bond Test Zeroing
can subtract up to 1.99 Ω.
Insulation Test (Riso)
Display Range
0 to 299 MΩ.
Accuracy
+ (5% + 2 counts) from 0.1 to 300 MΩ.
Resolution
0.01 MΩ (0 to 19.99 MΩ)
0.1 MΩ (20 to 199.9 MΩ)
1 MΩ (200 to 299 MΩ).
Test Voltage
500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0 % +25 % at 250 kΩ load.
Test Current
> 1 mA at 500 kΩ load, < 15 mA at 0 Ω.
Auto Discharge Time
< 0.5 s for 1 µF.
Max. Capacitive Load
Operational up to 1 µF.
Touch Current Test
Display Range
0 to 1.99 mA AC.
Accuracy
+ (4% + 2 counts).
Resolution
0.01 mA.
Internal Resistance (via Probe)
2 kΩ.
Measuring Method
Probe*.
Substitute Leakage Current Test
Display Range
0 to 19.99 mA AC.
Accuracy
+ (2.5% + 3 counts).
Resolution
0.01 mA.
Test Voltage
100 V AC + 20%.
Load/Leakage Test: Load Current
Display Range
0 A to 13 A.
Accuracy
+ (4% + 2 counts).
Resolution
0.1 A*.
Load/Leakage Test: Load Power
Display Range 230 V Mains
0.0 VA to 3.2 kVA.
Accuracy
+ (5 % + 3 counts).
Resolution
1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*.
Load/Leakage Test: Leakage Current
Display Range
0 to 19.99 mA.
Accuracy
+ (4% + 4 counts).
Resolution
0.01 mA*.
PELV Test
Accuracy at 50 Hz
+ (2% + 3 counts).
Overload Protection
300 V rms.
Warning Threshold
25 V rms.
RCD Test: Trip Current
Operational Error
+10 %.
Nominal
30 mA.
Accuracy
+5 %.
RCD Test: Trip Time
Standard Requirement
61557 Part 6; tolerance of rated test current 0 % to +10 %.
Operational Error
+10 %.
RCD Type
AC general-purpose 30 mA.
Display Range
310 ms.
Resolution
0.1 ms.
Accuracy
3 ms.
Trip Time Limit at 100 % (30 mA)
300 ms.
Trip Time Limit at 500 % (150 mA)
40 ms.
*The appliance under test is energised at mains potential.
Environmental Specifications
Operating Temperature
0 to 40 °C.
Relative Humidity
Non condensing < 10 °C
95% from 10 to 30 °C
75% from 30 to 40 °C.
Safety Specifications
Safety Rating
Complies with EN61010-1 3rd edition.
CAT II, 300 V, pol 2.
Mechanical & General Specifications
Dimensions
200 mm (L) x 275 mm (W) x 114 mm (H).
Weight
3.13 kg.
Power Supply
230 V +10 % -15 %, 50 Hz +2 Hz or (6500-2 only: 110V +10 % -15 %,50 Hz +2 Hz).
Power Consumption (Tester)
13 W typical (idle)
60 W max. during 25A Bond test.
Storage
Temperature
-10 to 60 °C.
Corrosion
70 °C @ 95 % RH for 5 days max.
Operating Altitude
0 up to 2000 m.
Sealing
IP-40 (enclosure), IP-20 (connectors).
EMC
Complies with EN61326-1, portable.
EMI Immunity
3 V/m.
Fluke 6500-2 warranty
2 years.
For more information on Fluke 6500-2 Portable Appliance Tester talk to Cuthbertson Laird Group