Sign In
The Fluke 724 Temperature Calibrator is a handheld, battery-operated instrument that measures and sources a variety of thermocouples and RTDs.
Now you can carry one tool to test all temperature sensors and transmitters in your plant. The Fluke 724B can measure and source 12 thermocouple types and seven RTD types, plus volts and ohms.
The Fluke 724 even handles high-speed pulsed RTD circuits and provides loop power. The dual-line measure/source display lets you source temperature and view loop current at the same time. And with its simple, "no menus controls, you'll be able to get all your testing done faster.
FEATURES
Easy to read dual display lets you view input and output simultaneously.
Measure RTDs, thermocouples, ohms, and volts to test sensors and transmitters.
Source/simulate thermocouples, RTDs, volts, and ohms to calibrate transmitters.
Perform fast linearity tests with 25% and 100% steps.
Execute remote tests with auto step and auto ramp.
Power transmitters during test using loop power supply with simultaneous mA measurement.
Store frequently-used test setups for later use.
Compact, streamlined shape makes it easy to carry.
Rugged, reliable design stands up to field use.
Backlight lets you work in poor light.
Large battery capacity of four AA cells.
Battery door for easy changes.
Fluke 724 Specifications
Measurement Accuracy
Voltage DC
30.000 V
0.02% + 2 counts (upper display).
20.000 V
0.02% + 2 counts (lower display).
100.00 mV
0.02% + 2 counts.
-10.00 mV to 75.00 mV
0.025% + 1 count (via TC connector).
Current DC
24.000 mA
0.02% + 2 counts.
Resistance
0.0 to 400.0 Ω
0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire).
401 to 1500 Ω
0.5 Ω (4-wire), 1 Ω (2- and 3-wire).
1500 to 3200 Ω
1 Ω (4-wire), 1.5 Ω (2- and 3-wire).
Source Accuracy
Voltage DC
100.00 mV
0.02% + 2 counts.
10.000 V
0.02% + 2 counts.
-10.00 mV to 75.00 mV
0.025 % + 1 count (via TC connector).
Resistance
15.0 to 400.0 Ω
0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA).
401 to 1500 Ω
0.5 Ω (excitation current 0.05 to 0.8 mA).
1500 to 3200 Ω
1 Ω (excitation current 0.05 to 0.4 mA).
RTDs and Thermocouples
Measure accuracy
NI-120
0.2°C.
PT-100 (385)
0.33°C.
PT-100 (393)
0.3°C.
PT-100 (JIS)
0.3°C.
PT-200 (385)
0.2°C.
PT-500 (385)
0.3°C.
PT-1000 (385)
0.2°C.
Resolution
0.1°C.
J
0.7°C.
K
0.8°C.
T
0.8°C.
E
0.7°C.
R
1.8°C.
S
1.5°C.
B
1.4°C.
L
0.7°C.
U
0.75°C.
N
0.9°C.
Resolution
J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F.
XK
0.6°C.
BP
1.2°C.
Source accuracy
NI-120
0.2°C.
PT-100 (385)
0.33°C.
PT-100 (393)
0.3°C.
PT-100 (JIS)
0.3°C.
PT-200 (385)
0.2°C.
PT-500 (385)
0.3°C.
PT-1000 (385)
0.2°C.
Resolution
0.1°C.
Accuracy stated for 4-wire measurement.
J
0.7°C.
K
0.8°C.
T
0.8°C.
E
0.7°C.
R
1.4°C.
S
1.5°C.
B
1.4°C.
L
0.7°C.
U
0.75°C.
N
0.9°C.
Resolution
J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C.
XK
0.6°C.
BP
1.2°C.
Specifications
Ramp functions
Source functions
Voltage, current, resistance, frequency, temperature.
Ramps
Slow ramp, Fast ramp, 25% step-ramp.
Loop power function
Voltage
24 V.
Accuracy
10%.
Maximum current
22 mA, short circuit protected.
Step functions
Source functions
Voltage, current, resistance, frequency, temperature.
Steps
25% of range, 100% of range.
Environmental Specifications
Operating temperature
-10°C to 55°C.
Storage temperature
-20°C to 71°C.
Humidity (without condensation)
90%
10°C to 30°C.
75%
30°C to 40°C.
45%
40°C to 50°C.
35%
50°C to 55°C.
Safety Specifications
Safety rating
CSA C22.2 No. 1010.1:1992.
EMC
EN50082-1:1992 and EN55022:1994 Class B.
Mechanical and General Specifications
Dimensions
96 x 200 x 47 mm.
Weight
650 g.
Batteries
Four AA alkaline batteries.
Fluke 724 warranty
Three years.
Battery life
25 hours typical.
Shock and vibration
Random, 2 G, 5-500 Hz.