The hand-held, battery-operated Fluke 772 Milliamp Process Clamp Meter can be used in troubleshooting transmitters, valves, PLC and DCS I/O. Unlike conventional clamp meters, the 772 features a remote jaw that is connected to the main body via extension cable. The detachable clamp with extension cable allows you to take measurements in tight locations, and the built-in spot light illuminates hard to see wires in dark enclosures.
The Fluke 772 deliver a comprehensive range of test and measurement capabilities. Now technicians in process plants, industrial plants, commercial buildings and automation commissioning teams can choose exactly the range of capabilities they need, at a price that makes sense.
FEATURES
Loop calibrator that measures 4 to 20 mA signals without breaking the loop.
Features best in class 0.2% accuracy.
Simultaneously measures the mA signal with the clamp and sources a mA signal.
Delivers 0.01 mA resolution and sensitivity.
Measures mA signals for PLC and control system analog I/O.
Data hold function.
Auto off and backlight timeout extend battery life.
Built-in measurement spotlight for illuminating darkened areas.
771, 772 & 773 Functions
mA Measure
w/jaw
mA Measure
In Circuit
mA Source
mA Sim
Loop Power
24 V
DC V Source
0 - 10 V
DC V Measure
0 - 30 V
Scaled mA Output
to mA Input
mA In/Out
Fluke 771
Fluke 772
Fluke 773
Fluke 772 Specifications
Diameter of measurable conductor
0.177” or 4.5 mm max.
Operating temperature
-10 to 50 °C.
Storage Temperature
-25 to 60°C.
Operating Humidity
< 90% @ <30 °C, < 75% @ 30 to 55°C.
Operating Altitude
0 to 2000 m.
IP Rating
IP 40.
Size
59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.).
Weight
260G, (9.1 oz.).
Vibration
Random 2 g, 5 to 500 Hz.
Shock
1 meter drop test (except the jaw).
EMI/RFI
Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to
specification for EMC field strengths of 1V/m up to 3V/m.
Temperature Coefficient
0.01% °C
(<18°C or > 28°C).
Power, battery life
(2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical.
Warranty
Three years for electronics one year for cable and clamp assembly.
Functional Specifications
mA measurement
(Measured by clamp)
Resolution and Range: 0 to 20.99 mA
Accuracy: 0.2% + 2 counts
Resolution and Range: 21.0 mA to 100.0 mA
Accuracy: 1% + 5 counts.
mA measurement
(Measured in series with test jacks)
Resolution and Range
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2 counts.
mA source (Maximum mA Drive:
24 mA into 1,000 ohms)
Resolution and Range
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2 counts.
mA simulate
(Maximum voltage 50 V dc)
Resolution and Range
Resolution and Range: 0 to 24.00 mA
Accuracy: 0.2% + 2 counts.