When productivity is on the line and you need to solve problems fast, the Fluke 87V delivers the accuracy and advanced troubleshooting capabilities you need. Designed specifically to handle complex signals, the Fluke 87V industrial multimeter, allows you to gain productivity by taking the guesswork out of drive system troubleshooting even in loud, high energy, and high altitude locations.
The Fluke 87V has improved measurement functions, troubleshooting features, resolution and accuracy to solve more problems on motor drives, in plant automation, power distribution, and electro-mechanical equipment. The Fluke 87 Series V has a unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment.
FEATURES:
Accurate frequency measurements on adjustable speed drives (ASD) due to Fluke-designed low-pass filter.
Built-in thermometer allows temperature measurements without a separate thermometer.
Peak Min/Max allows capture of intermittents as fast 250 ?S.
Dual display resolution - 6000 or 20,000 counts - lets you see small changes in displayed readings.
CAT III 1000V, CAT IV 600V safety rated.
Fluke 87V Product Video
Fluke 87V Specifications
Voltage DC
Maximum Voltage
1000 V.
Accuracy
+(0.05% + 1).
Maximum Resolution
10 µV.
Voltage AC
Maximum Voltage
1000 V.
Accuracy
+(0.7% + 2) true RMS.
AO Bandwidth
20kHz with low pass filter; 3 dB @ 1k Hz.
Maximum Resolution
0.1 mV.
Current DC
Maximum Current
10 A (20 A for 30 seconds max).
Accuracy
+(0.2% + 2).
Maximum Resolution
0.01 µA.
Current AC
Maximum Current
10 A (20 A for 30 seconds max).
Accuracy
+(1.0%+2) true RMS.
Maximum Resolution
0.1 µA.
Resistance
Max Resistance
50 MΩ.
Accuracy
+(0.2% + 1).
Maximum Resolution
0.1 Ω.
Capacitance
Maximum Capacitance
9999 µF.
Accuracy
+(1%+2).
Maximum Resolution
0.01 nF.
Frequency
Maximum Frequency
200 kHz.
Accuracy
+(0.005%+1).
Maximum Resolution
0.01 Hz.
Duty Cycle
Maximum Duty Cycle
99.9%.
Accuracy
+(0.2% per kHz + 0.1%).
Maximum Resolution
0.1%.
Temperature
Measurement Ranges
-200 to 1090° C
-328 to 1994° F (excluding probe).
Conductance
Maximum
60.00 nS.
Accuracy
+(1.0% + 10).
Maximum Resolution
0.01 nS.
Diode
Range
3 V.
Resolution
1 mV.
Accuracy
+(2%+1).
Duty Cycle
Accuracy
Within +(0.2% per kHz +0.1%).
Environmental Specifications
Operating Temperature
-20 to +55° C.
Storage Temperature
-40 to +60° C.
Humidity (Without Condensation)
0 to 90% (0 to 35° C)
0 to 70% (35 to 55° C).
Operating Altitude
2000 m.
Safety Specifications
Overvoltage Category
EN 61010-1 to 1000V CAT III, 600V CAT IV.
Agency Approvals
UL, CSA, T-V, VDE listed.
Mechanical/General Specifications
Dimensions
201 x 98 x 52mm (with holster).
Weight
355g (624g with holster).
Display
Digital - 6000 counts, updates 4/sec (19999 counts in high resolution mode)
Analogue - 32 segments, updates 40/sec
Frequency - 19999 counts, updates 3/sec at >10Hz.
Fluke 87V Warranty
Lifetime.
Battery Life
Alkaline - 400 hours typical (without backlight).
Shock
1m drop-tested per IEC 61010-1: 2001.
Vibration
Per MIL-PRF-28800 for a class 2 instrument.