KEY FEATURES
Unique function for accurate voltage and frequency measurements on adjustable speed motor drives.
Built-in thermometer.
Large digit display with bright, two-level backlight.
True-rms ac voltage and current for accurate measurements on non linear signals.
Selectable filter for accurate voltage and frequency measurements on motor drives.
0.05% DC accuracy.
6000 counts, 3-3/4 digits.
4-1/2 digit mode for precise measurements (20,000 counts).
Measure up to 1000 V AC and DC.
Measure up to 10 A, 20 A for up to 30 seconds.
Frequency to 200 kHz and % duty cycle.
Resistance, continuity and diode test.
10,000 µF capacitance range for components and motor caps.
Min/Max-Average recording with Min/Max Alert to capture variations automatically.
Peak capture to record transients as fast as 250 ?s.
Relative mode to remove test lead interference from low ohms measurements.
Auto and manual ranging for maximum flexibility.
Touch Hold to capture stable readings avoiding noisy signals.
Analog bargraph for fast changing or unstable signals.
Input Alert provides audible warning against wrong use of input jacks.
Improved selectable sleep mode for long battery life.
Access door for fast battery changes without breaking the calibration seal.
Fluke 87V Product Video
Fluke 87V Specifications
Voltage DC
Maximum Voltage
1000 V.
Accuracy
+(0.05% + 1).
Maximum Resolution
10 µV.
Voltage AC
Maximum Voltage
1000 V.
Accuracy
+(0.7% + 2) true RMS.
AO Bandwidth
20kHz with low pass filter; 3 dB @ 1k Hz.
Maximum Resolution
0.1 mV.
Current DC
Maximum Current
10 A (20 A for 30 seconds max).
Accuracy
+(0.2% + 2).
Maximum Resolution
0.01 µA.
Current AC
Maximum Current
10 A (20 A for 30 seconds max).
Accuracy
+(1.0%+2) true RMS.
Maximum Resolution
0.1 µA.
Resistance
Max Resistance
50 MΩ.
Accuracy
+(0.2% + 1).
Maximum Resolution
0.1 Ω.
Capacitance
Maximum Capacitance
9999 µF.
Accuracy
+(1%+2).
Maximum Resolution
0.01 nF.
Frequency
Maximum Frequency
200 kHz.
Accuracy
+(0.005%+1).
Maximum Resolution
0.01 Hz.
Duty Cycle
Maximum Duty Cycle
99.9%.
Accuracy
+(0.2% per kHz + 0.1%).
Maximum Resolution
0.1%.
Temperature
Measurement Ranges
-200 to 1090° C
-328 to 1994° F (excluding probe).
Conductance
Maximum
60.00 nS.
Accuracy
+(1.0% + 10).
Maximum Resolution
0.01 nS.
Diode
Range
3 V.
Resolution
1 mV.
Accuracy
+(2%+1).
Duty Cycle
Accuracy
Within +(0.2% per kHz +0.1%).
Environmental Specifications
Operating Temperature
-20 to +55° C.
Storage Temperature
-40 to +60° C.
Humidity (Without Condensation)
0 to 90% (0 to 35° C)
0 to 70% (35 to 55° C).
Operating Altitude
2000 m.
Safety Specifications
Overvoltage Category
EN 61010-1 to 1000V CAT III, 600V CAT IV.
Agency Approvals
UL, CSA, T-V, VDE listed.
Mechanical/General Specifications
Dimensions
201 x 98 x 52mm (with holster).
Weight
355g (624g with holster).
Display
Digital - 6000 counts, updates 4/sec (19999 counts in high resolution mode)
Analogue - 32 segments, updates 40/sec
Frequency - 19999 counts, updates 3/sec at >10Hz.
Fluke 87V Warranty
Lifetime.
Battery Life
Alkaline - 400 hours typical (without backlight).
Shock
1m drop-tested per IEC 61010-1: 2001.
Vibration
Per MIL-PRF-28800 for a class 2 instrument.