Sign In
Today’s HVAC technicians want a simple solution for diagnosing ventilation issues. Differential pressure measurements only tell part of the story. Technicians also want to measure air velocity and flow, without having to resort to expensive, difficult to use, specialist tools. The Fluke 922 makes airflow measurements easy by combining three tools: differential pressure, airflow, and velocity into a single, rugged meter.
The Fluke 922 was designed and built for how (and where) you do your job, with performance, ruggedness and ease of use, setting the Fluke 922 apart from the competition. The bright white display and ruggedized holster and wrist strap let you take the Fluke 922 into less than ideal environments. The color-coded hoses help you keep track of where your readings are coming from. The simple, intuitive interface means you can measure pressure, velocity, or airflow at the push of a button.
FEATURES:
Powerful meter provides differential and static pressure, air velocity and flow readings.
Convenient coloured hoses help proper interpretation of pressure readings.
Easy to use without sacrificing performance.
Bright, backlit display for clear viewing in all environments.
User-defined duct shape and size for maximum airflow accuracy.
Resolution down to 0.001 in H2O.
99 point data storage capacity.
Min/Max/Average/Hold functions for easy data analysis.
Auto power off saves battery life.
Fluke 922 Specifications
Air Pressure
Range/Resolution/Accuracy
+ 4000 Pascals / 1 Pascal / + 1 % + 1 Pascal
+ 16 in H2O / 0.001 in H2O / + 1 % + 0.01 in H2O
+ 400 mm H2O / 0.1 mm H2O / + 1 % + 0.1 mm H2O
+ 40 mbar / 0.01 mbar / + 1 % + 0.01 mbar
+ 0.6 PSI / 0.0001 PSI / + 1 % + 0.0001 PSI.
Air Velocity
Range/Resolution/Accuracy
250 to 16,000 fpm / 1 fpm / + 2.5 % of reading at 2000 fpm (10.00 m/s)
1 to 80 m/s / 0.001 m/s / + 2.5 % of reading at 2000 fpm (10.00 m/s).
Air Flow (Volume)
Range/Resolution/Accuracy
0 to 99,999 cfm / 1 cfm / Accuracy is a function of velocity and duct size
0 to 99,999 / 1 m3/hr / Accuracy is a function of velocity and duct size
0 to 99,999 l/s / 1 l/s / Accuracy is a function of velocity and duct size.
Temperature
Range/Resolution/Accuracy
0 °C to 50 °C / + 1 % + 2 °C / 0.1 °C
32 °F to 122 °F / + 1 % + 4 °F / 0.1 °F.
General Specifications
Operating Temperature
0 °C to +50 °C (+32 °F to +122 °F)
Storage Temperature
-40 °C to +60 °C (-40 °F to +140 °F).
Relative Humidity
0% to 90%, non-condensing.
IP Rating
IP40.
Operating Altitude
2000 m.
Storage Altitude
12000 m.
EMI, RFI, EMC
Meets requirements for EN61326-1.
Vibration
MIL-PREF-28800F, Class 3.
Max Pressure at Each Port
10 PSI.
Data storage capacity
99 readings.
Power
Four AA batteries.
Battery Life
280 hours without backlight, 60 hours with backlight.
Dimensions
9.2 x 6.1 x 3 inches.
Weight
1.6 pounds.
Fluke 922 warranty
2 years.