3 PH N5K power analyser w/50
The Fluke Norma 5000 Six-Phase Power Analyzer is a rugged, high-precision analyzer providing unmatched price performance for easy and reliable use in the field, or as a bench unit in laboratories and on test benches.
Based on a patented, high-bandwidth architecture, the instruments deliver high-precision measurements of single or three-phase current and voltage, harmonics analysis, Fast Fourier Transformation (FFT) analysis, as well as calculations of power and other derived values.
Applications
Electric motors and inverter drive systems - Through detailed spectrum analysis and dynamic torque calculation capabilities, switching losses caused by the inverter are accurately measured, and a thorough evaluation is made of torque transients and harmonics at higher frequencies.
Inverter drive system - Simultaneous measurement of all electrical and mechanical power parameters in the same time window enables users to observe the influence one component has on another, or on the whole system.
Lighting systems - A wide bandwidth of up to 10 MHz and a high sampling rate up to 1 MHz provide detailed signal analysis at ballast outputs. A unique shunt technique enables power measurements at very high frequencies. Simultaneous measurement of input and output power provides instant calculation of ballast losses.
Transformers - Synchronous six-phase power measurements enable highly accurate efficiency and loss calculations of large power transformers even at very low power factors. Synchronous multiphase resistance measurements of transformer coils are also possible.
Automotive - Synchronous electrical input and mechanical output measurements provide complete data on the efficiency and losses of individual components as well as the whole drive system.
FEATURES
Compact, high precision power analyzers - easy to carry and save working space.
Simple user interface ensures easy, intuitive operation.
Standard confi gurations allow users to specify the exact functionality required for their own unique application. Accurately display dynamic events on all phases at exactly the same point in time with simultaneous parallel acquisition of all phases.
All inputs are galvanically isolated to avoid short circuits in all applications.
Voltage, current and power harmonics up to the 40th.
FFT analysis, vector diagram display, recorder function and Digital Oscilloscope (DSO) mode included.
User-selectable average time - from 15 ms up to 3600 s - for dynamic measurements.
4 MB on-board memory for storage of measured values.
RS232 and USB available as standard;optional IEEE 488/Ethernet available.
Optional process interface available to measure torque and speed with external sensors; includes four analog outputs for easy use on motor and drive applications.
341 kHz or 1 MHz sample rates for detailed signal analysis.
Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision.
Includes Fluke NormaView PC software for setup, data download, analysis.
Fluke Norma 5000 Specifications
General Specifications
Number of Phases
1 to 3.
Weight
Approx. 5 kg (11 lb).
Size
150 x 237 x 315 mm.
5.9 x 9.3 x 12.4 in.
On-board Printer
No.
Display
Colour, 5.7 in / 144 mm - 320 x 240 pixel.
User-selectable background lighting and contrast.
Bandwidth
DC to 3 MHz or DC to 10 MHz depending on input module.
Basic Accuracy
0.2%, 0.1% or 0.03% depending on input modules.
Sampling Rate
0.33 MHz or 1 MHz depending on input modules.
Voltage Input Range
0.3 V to 1000 V.
Current Input Range (direct, not via shunt)
0.03 mA to 20 A depending on input module.
Memory for Configurations
4 MB.
Memory for Settings
0.5 MB.
Fast Fourier Transformation (FFT)
To the 40th harmonic.
RS232/USB Interface
Standard.
PI1 Process interface (8 analog/impulse inputs and 4 analog outputs)
Optional.
IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s)
Optional.
Fluke NormaView PC software (for data download, analysis and report writing)
Standard.
Basic Functions
Fast Fourier Transformation (FFT)
Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time.
Measured values: U, I, P per phase.
Order: 1st to 40th harmonics, maximum half sample frequency.
Digital Oscilloscope (DSO)
Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion.
Integration function (energy)
Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available.
Vector Display
Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal.
Recorder
Display of average values over time for trend determination.
RAM data memory
Storing of sample and average values; setting of start and stop conditions.
From the RAM approximately 4 MB are available for the storage of measured values.
Configuration
Set up the analyzer to measure and display data in the format required.
Ambient Conditions
Working Temperature Range
5°C to 35°C (41°F to 95°F).
Storage Temperature Range
-20°C to 50°C (-4°F to 122°F).
Housing Material
Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements.
Climatic Class
KYG DIN 40040, max. 85% relative humidity, non-condensing.
Power supply
85 V AC to 264 V AC, 50 Hz to 60 Hz, DC 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models.
Measuring Inputs
Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket.
Operation
Membrane keyboard with cursor - function keys and direct functions.
Connections
Rear panel of the 3-phase Analyser.
Measured Values
Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values.
Urms effective value, Urm rectified mean, Um mean value.
Up-, Up+, Upp peak values.
Ucf crest factor Ucf, Uff form factor.
Ufc fundamental content.
Uthd distortion factor DIN, IEC.
Irms effective value, Irm rectified mean, Im mean value.
Ip-, Ip+, Ipp peak values.
Icf crest factor Icf, Iff form factor.
Ifc fundamental content.
Ithd distortion factor DIN, IEC.
P active power [W].
Q reactive power [Var].
S apparent power [VA].
?, cos. phase angular.
Integral function for active power P, reactive power Q, apparent power S, voltage (Um) and current (Im).
Number of digits 4 or 5 dependent on measured value.
Frequency and Synchronisation
Range
DC and 0.2 Hz to sample rate.
Accuracy
+0.01% of measured value (reading).
Channels which can be selected: all U/I or external input.
One of three low pass filter with different frequencies can be switched into the signal.
The frequency is always visible on the top of the screen.
The BNC synchronization socket on backside of the instrument can be used either as input or output.
Input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50 V.
The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency).
Configuration Memory
Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument.
Interface
RS232 interface for upload of firmware and data exchange with the PC. A printer can be connected over an external converter.
Options
IEEE 488.2 / 1 MBit/s.
Ethernet / 10 MBit/s or 100 Mbit/s.
Standards and Safety
Electrical Safety
EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III).
Degree of pollution 2, safety Class I.
EN 61558 for transformer.
EN 61010-2-031/032 for accessories.
Maximum inputs
For voltage inputs Measurement range 1000 Veff, 2 kVpeak.
For current inputs Measurement range 10 Aeff, 20 Apeak.
Test voltage
Net input
case (protective conductor): 1.5 KV AC.
Net connection
Measurement input: 5.4 kV AC.
Measurement inputs
Case: 3.3 kV AC.
Measurement input
input: 5.4 kV.
Electromagnetic susceptibility
Emission
IEC 61326-1, EN 50081-1, EN 55011 Class B.
Immunity
IEC 61326-1 / Annex A (industrial sector), EN 50082-1.
Power Phases
The Fluke Norma 4000 Power Analyzer can be equipped with up to three power phases. Users can select the power phase best suited for their application.
Each modular plug-in power phase consists of a voltage and a current measurement channel. Each measuring channel is available for each basic unit, however only one kind of channel can be used per unit. Check standard configurations.
POWER PHASE OVERVIEW
Power Phase Channels
PP42
Accuracy
0.2% (0.1% rd + 0.1% rg).
Current range
20 A.
Sampling rate
341 kHz.
Bandwidth
3 MHz.
PP50
Accuracy
0.1% (0.05% rd + 0.05% rg).
Current range
10 A.
Sampling rate
1 MHz.
Bandwidth
10 MHz.
PP54
Accuracy
0.1% (0.05% rd + 0.05% rg).
Current range
10 A.
Sampling rate
341 kHz.
Bandwidth
3 MHz.
PP64
Accuracy
0.03% (0.02% rg + 0.01% rg).
Current range
10 A.
Sampling rate
341 kHz.
Bandwidth
3 MHz.
CURRENT SHUNTS
Planarshunt
Continuous load (Imin)
Range (Imax)
0.3 A.
32 A.
Nominal current (calibration point)
32 A.
Basic accuracy at calibration point [%]
+ 0.03.
Basic accuracy at nominal current [%]
+ 0.03.
Nominal voltage drop [V]
320 mV.
Nominal resistance [Ohm]
10 m?.
Short time overrange
(5s load 15s interval)
100A/ 1s-5s.
Overload Wmax
-
Bandwidth
DC - 1 MHz.
Frequency range
-
Angular accuracy [°/kHz]
+ 0.1.
Frequency influence [%/kHz]
-
Load influence [%/A2]
-
Temperature coefficient [ppm/K]
?10.
Weight (kg / lbs)
0.62 /1.36.
Triaxialshunts
Continuous load (Imin)
Range (Imax)
0.1 A
1 A
6 A
30 A
100 A
300 A
Nominal current (calibration point)
10 A
30 A
100 A
Basic accuracy at calibration point [%]
+ 0.03
+ 0.03
+ 0.1
Basic accuracy at nominal current [%]
+ 0.03
+ 0.03
+ 0.1
Nominal voltage drop [V]
100 mV
30 mV
20 mV
Nominal resistance [Ohm]
10 m?
1 m?
0.2 m?
Short time overrange (5s load 15s interval)
35 A
200 A
450 A
Overload Wmax
90 W
200 W
2 kW
Bandwidth
2 MHz
2 MHz
1 MHz
Frequency range
0 to 500 kHz
0 to 200 kHz
0 to 100 kHz
Angular accuracy [°/kHz]
+ 0.001
+ 0.002
+ 0.002
Frequency influence [%/kHz]
+ 0.0015
+ 0.0015
+ 0.01
Load influence [%/A2]
1 x 10-6
1 x 10-6
1 x 10-6
Temperature coefficient [ppm/K]
?15
?15
?10
Weight (kg / lbs)
0.75 / 1.65
0.75 / 1.65
1.2 / 2.65
Triaxialshunts (Cont.)
Continuous load (Imin)
Range (Imax)
2 A
18 A
18 A
450 A
1000 A
1500 A
Nominal current (calibration point)
150 A
300 A
500 A
Basic accuracy at calibration point [%]
+ 0.1
+ 0.1
+ 0.1
Basic accuracy at nominal current [%]
+ 0.1
+ 0.1
+ 0.1
Nominal voltage drop [V]
75 mV
15 mV
30 mV
Nominal resistance [Ohm]
0.5 m?
0.06 m?
0.06 m?
Short time overrange (5s load 15s interval)
650 A
1500 A
2000 A
Overload Wmax
10 kW
7.5 kW
10 kW
Bandwidth
DC - 500 MHz
DC - 500 kHz
DC - 200 kHz
Frequency range
0 to 100 kHz
0 to 20 kHz
0 to 20 kHz
Angular accuracy [°/kHz]
+ 0.025
+ 0.025
+ 0.025
Frequency influence [%/kHz]
+ 0.03
+ 0.03
+ 0.03
Load influence [%/A2]
0.5 x 10-6
0.2 x 10-6
0.5 x 10-6
Temperature coefficient [ppm/K]
?10
?10
?10
Weight (kg / lbs)
6 / 13.2
5.3 / 11.7
6 / 13.2
For more information on Fluke Norma 5000 Power Analyser talk to Cuthbertson Laird Group