Find The Needle Add My Company
Fluke Ti450 9Hz Thermal Imager
The Fluke Ti450 Infrared Camera, a high-end model in its Professional Series, takes focusing to a higher plane with MultiSharp™ Focus. An out-of-focus thermal image can be off by 20 degrees or more with no way to correct it once it has been captured, short of retaking new images. The Fluke® Ti450 Infrared Camera, compatible with Fluke Connect®, solves this problem by delivering in-focus images of everything in the field of view. MultiSharp™ Focus is a new technology that rapidly takes multiple images and combines them to produce one in-focus image. The advanced focusing system enables users to capture an automated, focused image of multiple targets at once, delivering the image clarity needed by professional thermographers and maintenance managers to produce top-quality results and avoid costly rework. The wireless Ti450 is part of Fluke Connect®, a system of wireless test tools that communicate via the Fluke Connect app, or Fluke Connect Assets software, a cloud-based solution that gathers measurements to provide a comprehensive view of critical equipment status. FEATURES Capture a clear, accurate image focused throughout the field of view with MultiSharp™ Focus. Uses a built-in laser distance meter that calculates and displays the distance from your designated target. Hot and cold temperature spot markers Get 4x the pixel data with SuperResolution. Wirelessly sync images directly from your camera to the Fluke Connect® system. Visual and infrared details all in one precisely blended or picture-in-picture image with IR-Fusion® technology. Monitor processes with video recording, video streaming, and remote control. See the details you need with interchangeable smart lenses - 2x and 4x telephoto and wide angle. All thermal imagers need sufficient warm-up time for the most accurate temperature measurements and best image quality. This time can often vary by model and by environmental conditions. Although most imagers are fully warmed up in 3-5 minutes, it is always best to wait a minimum of 10 minutes if the most accurate temperature measurement is important to your application. When you move the Imager between environments with large differences in ambient temperature, more adjustment time can be required. Fluke Ti450 Specifications: Key Features IFOV with standard lens (spatial resolution) 1.31 mRad, D:S 753:1. Detector resolution 320 x 240 (76,800 pixels) - or 640 x 480 with SuperResolution. SuperResolution Yes, on camera and in software. Captures and combines 4x the data to create a 640 x 480 image. MultiSharp™ Focus Yes, focused near and far, throughout the field of view. LaserSharp® Auto Focus Yes, for consistently in-focus images. Every. Single. Time. Laser distance meter Yes, calculates distance to the target for precisely focused images and displays distance on screen. Advanced manual focus Ruggedised touchscreen display 3.5 inch (landscape) 640 x 480 LCD. Rugged, ergonomic design for one-handed use Digital zoom 2x and 4x. Temperature Measurement Temperature measurement range (not calibrated below -10 °C) -20 °C to +1200 °C (-4 °F to +2192 °F). Accuracy +2 °C or 2% (at 25 °C nominal, whichever is greater). Thermal sensitivity (NETD) ?0.05 °C at 30 °C target temp (50 mK). Filter Mode (NETD improvement) ?0.03 °C at 30 °C target temp (30 mK). On-screen emissivity correction Yes (both value and table). On-screen reflected background temperature compensation On-screen transmission correction Wireless Connectivity To PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available). Fluke Connect® app compatible Yes, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect® app for saving and sharing. Fluke Connect® Assets optional software Yes, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location. Fluke Connect® Instant Upload Yes, connect your camera to your building's WiFi network, and images taken automatically upload to the Fluke Connect® system for viewing on your smartphone or PC. Fluke Connect® tool compatible Yes, connects wirelessly to select Fluke Connect® enabled tools and displays measurements on camera screen. Five simultaneous connections supported. IR-Fusion® Technology Adds the context of the visible details to your infrared image. AutoBlend™ mode Min, Mid, Max IR plus full visible on camera; continously variable in software. Picture-In-Picture (PIP) Built-in digital camera (visible light) 5 MP. Lenses Standard lens IFOV (spatial resolution) 1.31 mRad, D:S 753:1 Field of view 24 °H x 17 °V Minimum focus distance 15 cm (approx. 6 in) IR-Fusion® technology Picture-in-picture and full screen Optional 2x telephoto smart lens IFOV 0.65 mRad, D:S 1529:1 Field of view 12 °H x 9 °V Minimum focus distance 45 cm (approx. 18 in) IR-Fusion® technology Picture-in-picture and full screen Optional 4x telephoto smart lens IFOV 0.33 mRad, D:S 2941:1 Field of view 6.0 °H x 4.5 °V Minimum focus distance 1.5 m (approx. 5 ft) IR-Fusion® technology Picture-in-picture and full screen Optional wide-angle smart lens IFOV 2.62 mRad, D:S 377:1 Field of view 46 °H x 34 °V Minimum focus distance 15 cm (approx. 6 in) IR-Fusion® technology Full screen Level & Span Smooth auto and manual scaling Fast auto toggle between manual and auto modes Fast auto-rescale in manual mode Minimum span (in manual mode) 2.0 °C (3.6 °F). Minimum span (in auto mode) 3.0 °C (5.4 °F). Data Storage & Image Capture Extensive memory options Removable 4 GB micro SD memory card, 4 GB internal flash memory, save to USB flash drive capability, upload to Fluke Cloud™ for permanent storage. Image capture, review, save mechanism One-handed image capture,review, and save capability. Image file formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files. Memory review Thumbnail and fullscreen review. Software SmartView® software - full analysis and reporting software and Fluke Connect® system. Export file formats with SmartView® software Bitmap (.bmp), GIF, JPEG, PNG, TIFF. Voice annotation 60 seconds maximum recording time per image; reviewable playback on camera, optional bluetooth headset available but not required. IR-PhotoNotes™ Yes (5 images). Text annotation Video recording Standard and radiometric. File formats video Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3). Streaming video (remote display) Yes, see the live stream of the camera display on your PC, smartphone, or TV monitor. Via USB, WiFi hotspot, or WiFi network to SmartView® software on a PC; via WiFi hotspot to the Fluke Connect® app on a smartphone; or via HDMI to a TV monitor. Remote control operation Yes, through SmartView® software or Fluke Connect® mobile app. Auto capture (temperature and interval) Battery Batteries (field-replaceable, rechargeable) Two lithium ion smart battery packs with five-segment LED display to show charge level. Battery life 3-4 hours per battery (*Actual life varies depending on settings and usage). Battery charge time 2.5 hours to full charge. Battery charging system Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter. AC operation AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz). Power saving User selectable sleep and power off modes. Colour Palettes Standard palettes 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted. Ultra Contrast™ palettes 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra. General Specifications Frame rate 9 Hz or 60 Hz versions. Laser pointer LED light (torch) Colour alarms (temperature alarms) High temperature, low temperature, and isotherms (within range). Center-point temperature measurement Spot temperature Hot and cold spot markers. User-definable spot markers 3 user-definable spot markers. Center box Expandable-contractible measurement box with MIN-MAX-AVG temp display. Infrared spectral band 7.5 ?m to 14 ?m (long wave). Operating temperature -10 °C to +50 °C (14 °F to 122 °F). Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries. Relative humidity 10% to 95% non-condensing. Safety IEC 61010-1: Overvoltage category II, Pollution Degree 2. Electromagnetic compatibility IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A. Australian RCM IEC 61326-1. US FCC CFR 47, Part 15 Subpart B. Vibration 0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6. Shock 25 g, IEC 68-2-29. Drop Engineered to withstand 2 meter (6.5 feet) drop with standard lens. Size (H x W x L) 27.7 x 12.2 x 16.7 cm (10.9 x 4.8 x 6.5 in). Weight (battery included) 1.04 kg (2.3 lb). Enclosure rating IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions). Fluke Ti450 Warranty Two-years (standard), extended warranties are available. Recommended calibration cycle Two-years (assumes normal operation and normal aging). Supported languages Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish.

For more information on Fluke Ti450 9Hz Thermal Imager talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title