Find The Needle Add My Company
Kewtech KT66DL Digital 12-in-1 Multifunction Tester
The Kewtech KT66DL 12-in-1 Multifunction Tester has been engineered with pioneering sophisticated loop testing systems, including 3 & 2 wire low current test options and a comprehensive RCD testing facility complete with EV charging point test capacity. The KT66DL has an easy-to-use single rotary dial with four function softkeys and a colour LCD 3.5” dot matrix display. It also incorporates Anti-Trip Technology (ATT) which electronically bypasses RCDs when performing loop impedance tests. This saves time and money by not having to take the RCD out of the circuit during testing and is a safer procedure to follow. With the ATT function enabled, a test of 15mA or less is applied between line & earth. It enables loop impedance measurements without tripping RCDs rated at 30mA and above. ATT supports measurements using three wires: Line, Earth, and Neutral and also two wires: Line and Earth. FEATURES Simultaneous display of L-N, L-N, L-E voltage (TRMS). Three modes of starting a test: single press of the test button, continuous testing and by test button in the test probe. Help display. Advanced memory - assigns DB, circuit no. and type of test i.e. Zs or Ze. Two continuity tests 200mA & 15mA . 55V loop test capability - suitable for 110V CTE systems. Padded neck strap. Supplied with G7 test leads and additional probe incorporating a test button. Tests Type AC, ACS, A, AS, F, B, BS & EV. UC - contact voltage test. Touch voltage pad with selectable limits. Heavy duty canvas carry case with extra room for you testing accessories. The KT66DL has a lid to further protect your instrument. It easily folds under the instrument when in use. Kewtech KT66DL 12 In 1 Multifunction Tester Specifications Continuity Range 20.00/200.0/2000Ω (auto-ranging). Display range 0.00 - 20.99Ω / 16.0 - 209.9Ω / 160 - 2099Ω. Measuring range 0 - 2000Ω. Accuracy +2.0%rdg+8dgt. Open-circuit voltage 7 - 14V DC. Test current 200mA test: 200mA or more (2Ω or less) 15mA test: 15mA+3mA (short-circuit). Enabled if pre-set NULL value is 9Ω or less. Buzzer: Buzzer sounds when measured resistance is 2Ω or less. Volts Range 300.0/600V (Auto-ranging) Display range Voltage: 2.0 - 314.9V, 240 - 629V Frequency: 40.0 - 70.0Hz (displayed at 2V or higher). Measuring range Voltage: 2 - 600V Accuracy Voltage: +2%rdg+4dgt Frequency: +0.5%rdg+2dgt. Uc (RCD) Mains voltage range 100-260V. Range 100V. Display range 0.0 - 104.9V. Measuring range 0 - 100V. Accuracy +5%to+15%rdg +8dgt 230V. Test current 50 % or less of I?n. Earth Precise measurement. Simplified measurement. Range 20.00 / 200.0 / 2000Ω (auto-ranging). Accuracy 20Ω range; +2%rdg+0.08Ω The other ranges: +2%rdg+3dgt (Aux. earth resistance: 100Ω). +2%rdg+0.08Ω The other ranges: +2%rdg+3dgt. Output current 20Ω range: approx. 3mA, 200v range: approx. 1.7mA 2000Ω range: approx. 0.7mA Frequency: 825Hz. Phase Rotation Measuring Range 48 - 600V / 45 - 65Hz. Criteria of judgement Correct sequence: Clockwise symbol and “1, 2, 3” are displayed Reversed sequence: Counter-clockwise symbol and “3, 2, 1” are displayed. Insulation Rated voltage 100V 250V 500V 1000V SPD (Varistor) 1000V Range 2.000/20.00/200.0MΩ auto-ranging 20.00/200.0/1000MΩ auto-ranging 20.00/200.0/2000MΩ 0 -1000V (increases in 1V steps) Display range 0.000 - 2.099MΩ 0.00 - 20.99MΩ 0.00 - 20.99MΩ 1049V 1.60 - 20.99MΩ 16.0 - 209.9MΩ 16.0 - 209.9MΩ 16.0 - 209.9MΩ 160 - 1049MΩ 160 - 2099MΩ Measuring range 0 - 200MΩ 0 - 1000MΩ 0 - 2000MΩ 0 - 1049V Accuracy 2.000MΩ range: +2%rdg+6dgt 20.00MΩ range: +(2%rdg+6dgt), 200.0MΩ range: +(2%rdg+6dgt) +5%rdg+5dgt 20.00MΩ range: +2%rdg+6dgt 1000MΩ range: +(5%rdg+6dgt) 2000MΩ range: +(5%rdg+6dgt) 200MΩ range: +5%rdg+6dgt Rated measurement current 1.0 - 1.2mA at 100kΩ 1.0 - 1.2mA at 250kΩ 1.0 - 1.2mA at 500kΩ 1.0 - 1.2mA at 1MΩ 1.0 mA Loop Function LOOP ATT LOOP HIGH 3-Wire L-PE 2-Wire L-PE L-PE0.01ΩRes L-PE0.001ΩRes L-N/L-L Mains input voltage range 100 - 260V 50/60Hz (L-N < 20Ω) 48 - 260V 50/60Hz 100 - 260V 50/60Hz 48 - 260V 50/60Hz Range LOOP 20.00/200.0/2000Ω (auto-ranging) 20.00/200.0/2000Ω 2.000Ω 20.00Ω PFC/PSC 2000A/20kA 2000A/20kA (PFC only) 2000A/50kA (PFC only) 2000A/20kA (PSC only) 2000A/20kA (PSC only) Display range LOOP 0.00 - 20.99Ω 21.0 - 209.9Ω 210 - 2099Ω 0.00 -20.99Ω 21.0 -209.9Ω 210 -2099Ω 0.00 - 20.99Ω 21.0 - 209.9Ω 210 -2099Ω 0.000 - 2.099Ω 0.00-20.99Ω PFC/PSC 0 - 2099A 2.10 - 20.99kA 0 - 2099A 2.10 - 20.99kA (PFC only) 0 - 2099A 2.10 - 50.49kA (PFC only) 0 - 2099A 2.10 - 20.99kA (PFC only) 0 - 2099A 2.10 - 20.99kA (PSC only) Meas. range LOOP 0 - 2000Ω 0 - 2000Ω 0 - 2000Ω 0 - 2Ω 0 - 20Ω Accuracy LOOP +(3%rdg+6dgt) +(3%rdg+10dgt) +(3%rdg+4dgt) +(3%rdg+25mΩ) +(3%rdg+4dgt) PFC/PSC Depending on the accuracies of voltage and LOOP measurements. Test current @ 230V L-N:6A/60ms N-PE:10mA (5.3Hz) L-PE: 15mA 20Ω: 6A/20ms, 200Ω: 0.5A/20ms 2000Ω: 15mA/500ms 25A/20ms 6A/20ms RCD Mains input voltage range: 100V - 260V 50/ 60Hz. For Type AC and A RCDs rated at 100mA or higher: 190 - 260V. Mode Rated residual operating current (mA)(I?n) Test current Duration Current (mA) rms Accuracy @230V Meas. time Accuracy x 1/2 AC G: 10/30/100/300/500/1000 S: 100/300/500 I?nx1/2 -8% to-2% VAR:-10% to 0% 2000ms Trip Time +(1%+2ms) Measuring time +3% of FS A/F G: 10/30/100/300/500 AS:100/300/500 I?nx1/2 -10% to 0% B G: 10/30/100/300 S:100/300 I?nx1/2 -10% to 0% x 1 AC G:10/30/100/300/500/1000 S: 100/300/500 I?n +2% to +8% VAR:0% to +10% G:550ms S:1000ms A/F G: 10/30/100/300/500 AS:100/300/500 I?nx1.4 (10mA: I?nx2) 0% to +10% B G: 10/30/100/300 S:100/300 I?nx2 0% to +10% 6 mA DC I?n 0% to +10% 10.5s x 5 AC G: 10/30/100 S: 100 I?nx5 +2% to +8% VAR:0% to +10% 410ms A/F G: 10/30/100 AS: 100 I?nx5x1.4 0% to +10% B 10/30 I?nx2x5 0% to +10% Ramp 20 to 110% AC 10/30/100/300/500 S: 100/300/500 I?n -4% to +4% by 10% G: 300ms S: 500ms Measuring time +3% of FS A/F G: 10/30/100/300/500 AS:100/300/500 I?nx1.4 (10mA:I?nx2) -10% to +10% B G: 10/30/100/300 S: 100/300 I?nx2 -10% to +10% by 2% /150ms Ramp EV 30 to 100% 6 mA DC I?n -10% to +10% by 2% / 500ms - General Applicable Standards IEC 61010-1 CATIII (600V) CATIV (300V) pollution degree 2, IEC 61010 -Tester , -2-030, -2-034, IEC61557-1,2,3,4,5,6,7,10, IEC 60529 IP40, EN 61326-2-2 (EMC). Battery type Size AA Alkaline battery (LR6) x 8. Display >Colour Dot Matrix LCD 320(W) X 240(H) pixels. Operating temperature -10 to +50°C. Dimensions 136 (L) x 235 (W) x 114 (D) mm. Weight 1300g including batteries (8 x AA / LR6).

For more information on Kewtech KT66DL Digital 12-in-1 Multifunction Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title