The Kikusui TOS5300 Series Withstanding Voltage and Insulation Resistance Testers perform withstanding voltage and insulation resistance tests, which are two of the four tests that are required for ensuring the safety of electrical products.
The TOS5300 is also equipped with a number of features that are capable of meeting a variety of test needs. It is a low-cost standard model that provides thorough operability, reliability and safety. The withstanding voltage test evaluates whether the electric insulation section of electric equipment or parts have sufficient dielectric strength for the working voltage. It is also called dielectric withstand test or hipot test.
FEATURES
Newly developed constant-voltage output for stable testing.
Rise time control feature that gradually increases the test voltage (only for withstandingvoltage tests).
Fall time control feature that gradually decreases the test voltage.
Calibration Protection feature that provides a notification when TOS5300 Series calibration is required.
Ability to save three sets of test conditions.
Standard-equipped USB port.
Protection against incorrect operations.
TOS5300 Basic Operation
Kikusui TOS5300 Specifications
AC Output Section
Output Range
0.05 kV to 5.00 kV.
Output Accuracy
+(2 % of set + 20V) when no load is connected.
Output Setting Range
0.00 kV to 5.50 kV.
Output Resolution
10 V steps.
Max. Rated Output
500 VA.
Max. Rated Voltage
5 kV.
Max. Rated Current
100 mA.
Transformer Rating
500 VA.
Output Voltage Waveform
Sine
Distortion: If the output voltage is 0.5 kV or more: 3 % or less.
Frequency
50 Hz or 60 Hz.
Accuracy
+0.5 %.
Voltage Regulation
10 % or less.
Input Voltage Variation
+0.3%.
Short-Circuit Current
200 mA or more.
Output Method
PWM switching.
DC Output Section
Output Range
0.05 kV to 6.00 kV.
Accuracy
+(2 % of set + 20V) when no load is connected.
Setting Range
0.00 kV to 6.20 kV.
Resolution
10 V steps.
Max. Rated Output
50 W (5 kV/10mA).
Max. Rated Voltage
6 kV.
Max. Rated Current
10 mA.
Voltage Regulation
3% or less ?When changing from maximum rated load to no load).
Short-Circuit Current
40 mA (when generation 6 kV output).
Discharge feature
Forced discharge after test completion (discharge resistance: 125 kΩ).
General Specifications
Display
VFD: 256 x 64 dots + 4 status indicators.
Backup battery life
3 years (at 25 °C or 77 °F).
Operating Temperature Range
0 °C to 40 °C (32 °F to 104 °F).
Voltage Range
100 VAC to 240 VAC (90 VAC to 250 VAC).
Earth continuity
25 AAC, 0.1 Ω or less.
Dimensions
330(w) x 150(h) x 420(l) mm.
Weight
Approx. 15 kg (33.1 lb.).
TOS5300 warranty