Sign In
The Martindale HPAT500/2 is a battery powered, hand held PAT tester with simple one-button test selection. It is ideal for use where there is no convenient power socket and provides a time saving solution when adopting a mobile approach to PAT testing.
Unlike similar PAT testers, the HPAT500/2 has a unique feature to counteract issues with testing appliances with long leads, or long extension leads, caused by the extra resistance added as a result of the lead length.
The HPAT500/2 has a new high contrast backlit display.
FEATURES
Simple One Button Operation.
Automatic Class I, Class II & power lead tests.
Pass / Fail Tester with Result.
Measured values displayed.
Selectable 250V insulation test for surge protected equipment.
I.T. safe 200mA DC earth bond test with two pass levels.
Rechargeable Batteries & Charger Included.
Low Current Bond Test for Sensitive IT Equipment.
Tests both 240V and 110V appliances.
Mains rechargeable with in-car option.
Ideal for Low Volume Testing.
Martindale HPAT500 Product Video
Martindale HPAT Comparison Chart HPAT400HPAT500/2HPAT600/2Class I /II Test???Lead Test???Pass/Fail Indication???Test Values Displayed-??Selectable Limits--?Test ModeAutoAutoAuto/ManualRun Test--SimulatedEarth Continuity Test Current200 mA200 mA200m AInsulation Test Voltage500 V250/500 V250/500 V110V AppliancesWith accessoryWith accessoryWith accessoryMemory--200 results for on-screen recallSupplyAlkaline batteriesRechargeableRechargeable
Martindale HPAT500/2 SpecificationsEarth ContinuityTest Voltage4 V DC (into open circuit).Test Current200 mA DC (into short circuit).Range0 to 19.99 Ω.Resolution0.01 Ω.Accuracy+ (5% of reading + 2 digits).Fixed Pass LimitsLead? 0.10 Ω = PASS
? 0.20 Ω = NOTE x.xx PASS.Class IClass I ? 0.10 Ω = PASS
? 0.20 Ω = NOTE x.xx PASS.InsulationFixed Voltage>500 V DC at 1 mA (< 600 V DC into open circuit).Test CurrentTest current: 1.5 mA (into short circuit).Ranges2.00 MΩ, 20.0 MΩ, 200 MΩ.Resolution0.01 MΩ.Accuracy<100 MΩ + (5% reading + 2 digits)
>100 MΩ + (10% reading + 2 digits).Fixed Pass LevelsLead: ? 1.0 MΩ
Class I: ? 1.0 MΩ
Class II: ? 2.0 MΩ.Fuse ChecksTest Voltage4V DC (into open circuit).Test Current200mA DC (into short circuit).Pass Level>2mA.GeneralOverload Protection300 V AC/DC.Protection ClassIP20.SafetyComplies to BS EN 61010-1: 2001.Temperature Range-10 to 40°C, non-condensing.Batteries6 x 1.2 V AA NiMH rechargeable batteries
1800mAh, or greater.Battery LifeFully charged, minimum 600 complete
tests. The HPAT500 will operate fully from the battery
charger in the event of discharged batteries. Do not
remove batteries.Auto Shut DownAfter 10 minutes of inactivity, or when battery low.Battery Charger Input230 V 50 Hz.Battery Charger Output12 V DC at 300mA, 5.5 jack x 2.5 bore centre
positive.Dimensions90 x 210 x 54 mm.WeightApprox 700g (including batteries & leads).