Find The Needle Add My Company
Martindale PD440SX AC Proving Unit
Safe electrical working requires the use of a voltage indicator that has been proven with a suitable proving device before and after use to ensure the instrument is working correctly in accordance with the Electricity at Work Regulations.The Martindale PD440SX has all the capabilities of the standard PD440S proving unit plus a unique CALCHECK feature for use with installation testers and 4 stepped voltage thresholds matched to common two pole tester thresholds. Both the PD440SX and the PD690SX ramp output voltage down in a sequence lasting for a duration of 10s, before reducing output voltage to zero.The CALCHECK feature makes it easy to verify the insulation and low resistance ranges on 18th Edition multifunction instruments and single function insulation testers on-site, making it ideal for identifying potential calibration issues with a multifunction tester prior to certifying a new wiring installation or carrying out a condition report. It’s also a valuable procedure recognised by electrical contractor assessment bodies. The proving unit output voltages are stepped with individual LED indicators for each voltage threshold from 50V to 440V matched to common two pole tester thresholds, ideal for identifying potential voltage tester calibration issues. On contact, the proving unit outputs the highest voltage first instantaneously checking all LEDs up to 440V and proving the tester for safe isolation use, it then steps down through each level automatically. At the end of the proving test, a low resistance appears across the terminals to verify the continuity function of two pole testers.FEATURESSafely proves the operation of voltage indicators and test lamps up to 440V. Unique CALCHECK function for multifunction installation tests. Individual LED indicators matched to voltage indicator thresholds. Long battery life with low battery indicator. Includes MAG3 high strength magnetic hanger. Colour coded for voltage output.Martindale PD Comparison PD690SPD440SXPD690SXMaximum Voltage Output690V AC440V AC690V AC.LED Voltage Thresholds690V50V, 120V, 230V, 440V.50V, 120V, 230V, 400V, 690V.High Voltage LED?Multiple.Multiple.Low Battery LED???High/Low Z Compatible???CALCHECK Resistance Values??Colour Coded to Match Voltage Indicators???Suitable forMultimeters, voltage testers & Drummond test lamps.Multimeters, voltage testers & Drummond test lamps.Multimeters, voltage testers & Drummond test lamps. Martindale PD440SX SpecificationsOutput voltage440/230/100/50 V nominal.Output frequency50 Hz nominal.Output loadingSee datasheet.CALCHECK insulation test resistance0.5 MΩ (max test voltage 1 kV) 1.0 MΩ (max test voltage 1 kV).CALCHECK continuity test resistance0.5 Ω (max test current 200 mA) 1.0 Ω (max test current 200 mA).Temperature (Operating & Storage)-10°C to 40°C.Humidity (Operating & Storage)max. 70% R.H.Altitudeup to 2000m.Pollution Degree2Power6 x 1.5 V, AA alkaline batteries (IEC LR6, NEDA 15A).Dimensions150 x 80 x 35 mm.Weight350g approx. with batteries.Martindale PD440SX warrantyTwo-years.

For more information on Martindale PD440SX AC Proving Unit talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title