![Find The Needle](/theme/images/logo.png)
Sign In
![Martindale VI13800 Voltage Indicator](https://images.findtheneedle.co.uk/findtheneedle/products/17295824.jpg)
With the release of the VI13800 voltage indicator and in accordance with BS EN61243-3:2010, Martindale have replaced the fused probes in favour of high wattage resistors. This update reduces the current in the event of a cable being damaged.
This long life voltage detector provides LED indicators which produce a clear and fast display of the voltage level range and show if a circuit is live. The detector can safely check for AC and DC voltages from 50V to 600V AC/DC.
FEATURES
Industry standard voltage indicator.
Same as VI-13700 but with no fuse.
Fully GS38 compliant.
Heavy duty double insulated leads.
Bright LEDs.
Polarity Indication.
Martindale VI13800 Specifications
Electrical
Nominal Voltage Range
50-600 V AC/DC RMS.
Nominal Voltage Threshold Indications
50, 100, 200, 400 V DC/AC RMS.
Voltage Threshold Tolerance
Conforms to BS EN 61342-3:2010.
Polarity and Voltage Indication
?12 V DC/AC RMS.
AC/DC Voltage Detection
Automatic.
Range Detection
Automatic.
Response Time
<0.1s.
Frequency Range
DC, 1 - 400 Hz.
Test Current
<3.5 mA at 600 V DC/AC RMS.
Duty Ratio
30s ON (operated) / 240s OFF (recovery).
Environmental
Temperature and Humidity (Operating and Storage)
-10 to 55°C ? 85% RH.
Altitude
Up to 2000m.
Safety
Conformity
To BS EN 61243-3:2010 CAT IV 600 V, CAT III 1000 V.
Class
Class II, double insulation.
Pollution Degree
2.
IP Rating
IP54.
EMC
BS EN 61326-1.
General
Power
From circuit under test.
Dimensions
205 (L) x 67 (W) x 27 (D) mm.
Weight
130g.
Includes
Instructions.
Martindale VI13800 warranty
Two-year.