Sign In
The Megger DCM300E Earth Leakage Clamp designed primarily to check earth leakage currents with a dedicated 30 mA range providing resolution down to 10 µA. The capabilities of the DCM300E extend to measuring currents of up to 300 A ac, making it a highly versatile instrument capable of taking current measurements in a wide variety of situations and applications.
The Megger DCM300E has 4 ranges: 30 mA, 300 mA, 30 A and 300 A with a best resolution of 0.01 mA. The analog-style bargraph of the DCM300E is very useful when monitoring changes, allowing the operator to easily interpret the rapidly changing bargraph rather than the digital display. Other key functions include the “Data Hold” feature which aids in measurements where there is a problem with accessibility or poor lighting, and the automatic power off feature that extends the battery life.
FEATURES
0,01 mA resolution for measuring earth leakage currents.
300 A range for standard current measurements.
Analogue Bargraph Display for trending.
Handguard designed for operator safety.
Pocket sized and lightweight.
Megger DCM300E Specifications
Measuring Method
Dual integration mode.
Measuring Function
Leakage current and load.
Display
3.5 digit LCD; max reading of 3200.
Range
0-30 mA, 300 mA, 30 A, 300 A (50/60 Hz).
Ranging
2 manual ranges.
Accuracy Specified at Operating Temperature
23°C +5°C: 80% RH max.
Range, Min Resolution and Accuracy
30/300 mA - 0.01/0.01 ma - +1.2% rdg +5dgt
30/300 A - 0.01/0.1 A - 200-250 A: +3.0% rdg +5 dgt. 250-300 A: +5.0% rdg + 5 dgt.
Jaw Opening Capability
40 mm.
Over Range Indication
"OL" mark on LCD screen.
Maximum Indication
3200.
Low Battery Indication
2.5 V - 2.7 V; ("+-") mark on LCD.
Data Hold Indication
"DH" mark on LCD screen.
Sampling Time
Approx 2 times/sec (digital display)
Approx 12 times/sec (bargraph display).
Auto Power Off
The meter will power down after approx 10 minutes of switching on.
Limitation of Circuit Voltage
Less than 600 V AC.
Withstanding Voltage
AC 3700 V/1 minute max. (between the core of CT and the unit housing).
Operating Temperature
0 to 40°C <80% RH (non-condensing).
Storage Temperature
-10 to 60°C <70% RH (non-condensing).
Power Supply
2 x 1.5V button cells (LR44 or SR44).
Power Consumption
Approx 5mW.
Battery Life
Approx 50 hours (LR44).
Dimensions
64 x 176 x 23 mm (2.5 x 7 x 9 inches) (width x height x depth).
Weight
Approx 125g (1/4 lb approx).
Safety
EN61010-1 and EN61010-2-032 300V phase to earth
500V phase to phase CAT III or 600V CAT II double insulated.
EMC
In accordance with IEC61326 including amendment number 1.
For more information on Megger DCM300E Earth Leakage Clampmeter talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.