Find The Needle Add My Company
Megger DET4TD2 Four Pole Earth Kit
Megger’s DET4 family of ground testing instruments offers a unique solution to your ground rod and soil resistivity testing needs. The ground tester is rated to IP54 making it truly an outdoor instrument. The DET4TD2 has been designed to be easy to use, a large selector switch makes selection of 2 pole, 3 pole or 4 pole test easy with gloved hands - and the design makes the fitting of shorting links to perform 2 pole tests a thing of the past. A large, clear, easy to read LCD display and thumb sized test button again makes the instrument particularly suited to the outdoor conditions of ground testing. In addition to this ease of use the ground tester also automatically checks the connection and condition of the P spike and the C spike, indicating the status on the display. The instrument also includes a voltmeter to allow you to measure the ground voltage. The ground tester can measure resistance from 0.01 Ω through to 20 kΩ and earth voltages up to 100 V. To allow testing in noisy environments the instrument is capable of rejecting noise of up to 40 V peak to peak. The DET4TD2 digital ground tester is powered from 8 AA batteries which are widely available and deliver excellent testing time. FEATURES IP54 rated 2, 3 and 4 point testing Selectable 25 V or 50 V output Dry cell or rechargeable versions Simple one button operation Robust carry case Delivered with calibration certificate Megger DET4TD2 Specifications Ingress Protection IP54. C Spike, P Stake and Noise Check Automatic. Noise Rejection 40 V Peak to Peak. 2-Wire, 3-Wire, 4-Wire Tests Yes, with no shorting links required. Instrument Output Voltage: + 25 V or + 50 V at 128 Hz Current: 4.5 mA or 0.45 mA. Resistance Range 0.01 Ω to 20 kΩ. Earth Voltage Range 0 to 100 V. Resistance Accuracy 2P measurements: 2% +3 digits 3P measurements: 2% +3 digits 4P measurements: 2% +3 digits. Maximum Probe Resistance Rp limit: 100 kΩ (50 V output voltage) Rc limit: 100 kΩ (50 V output voltage) Limits reduced to 50 kΩ for 25 V output voltage Limits reduced to 5 kΩ for 0.01 Ω resolution. Ground Voltage Range 0 to 100 V AC. Ground Voltage Accuracy 2% + 2 V. Display 3½ high contrast liquid crystal. Battery Type 8 off AA (LR6) cells. Operating Temperature Range -15 to +55 °C / 5 °F to 131 °F. Storage Temperature Range -40 to +70°C / -40 °F to 158 °F. Safety Complies with the requirements of IEC61010-1 100 V CAT IV between terminal pairs.* * The CAT IV 100 V is dependant on the use of a leadset of at least this rating, for example the optional two wire leadset part number 1001-858. EMC In accordance with IEC61326-1. Standards Compliance Complies with the requirements of KEMA K85B. Complies with the following parts of EN61557, “Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. - Equipment for testing, measuring or monitoring of protective measures”. Part 1 - General requirements Part 5 - Resistance to earth. Dimensions 203 x 148 x 78 mm (8 x 5.8 x 3 inches). Weight 1 kg (2.2lb). Megger DET4TD2 warranty 2 years.

For more information on Megger DET4TD2 Four Pole Earth Kit talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title