Find The Needle Add My Company
Megger EV Test Kit 1
*** The new electric vehicle charge point testing kit from Megger includes the MFT1741+ & the EVCA210-UK EV adapter (list price ?2160) and is being offered with a massive ?945 discount whilst stocks last. *** Megger Components Shortage PLEASE NOTE: Megger is currently experiencing a global shortage of components for their popular MFT 1700 Series. We are currently operating a waiting list and as stock becomes available we will ship your order. If you would like to get your hands on these industry-leading MFT's, then we strongly advise that you get in the queue. The Megger MFT1741+ Multifunction Tester & EVCA210-UK EV Charge-Point Adapter Kit includes: Megger MFT1741+ Multifunction Tester with Standard Accessories. Megger EVCA210-UK Electric Vehicle Charge-Point Adapter with Standard Accessories. The Megger EVCA210 is a compact, simple to use adapter designed to perform all the functions required by the electrical contractor to fully test Mode 3 AC Electric Vehicle Charge-points. Specially designed to comply with UK, European and other International wiring regulations and standards, the EVCA210 may be used on all single and three phase electric vehicle charge points with appropriate connectors. The Megger MFT1741+ multifunction tester is an instrument designed for testing low voltage electrical installations and especially in locations that suffer from high electrical noise. It provides all the tests required to complete the necessary electrical certification for industrial, commercial and domestic fixed wiring installations. The MFT1741+ offers a wide range of test functions, designed for all electrical installation testing and verification of low voltage building wiring and distribution testing scenarios. The MFT1741+ is IEC 61010 CAT IV 300 V rated for safe connection anywhere within the LV network on single and 3 phase systems. FEATURES Testing of Electric Vehicle Charge Points*. Enhanced non-trip loop impedance measurement technology. “Confidence meter” measurement analysis (patent pending). Full single and 3 phase compliant installation testing. 10 mA to 1 A single and 3 phase RCD testing. Earth testing and stake-less testing for electrode resistance measurement*. Simple colour-coded test selection. Ambidextrous operation. Internal memory and Bluetooth® communications. EN61010 CAT IV safety rating and tough IP54 case. Megger MFT1741+ Specifications Insulation Test Output voltage -0% +20% at rated load or less. Voltage display +3% +3 digits +0.5% of rated voltage. Short circuit current 1.5 mA nominal test current. Test current on load 1 mA at min pass values of insulation. Insulation Accuracy 1000 Volts 10 kΩ ~ 999 MΩ +3% +2 digits. 500 Volts 10 kΩ ~ 500 MΩ +3% +2 digits. >500 MΩ +10% +4 digits. 250 Volts 10 kΩ ~ 250 MΩ +3% +2 digits. >250 MΩ +10% +4 digits. 100 Volts 10 kΩ ~ 100 MΩ +3% +2 digits. >100 MΩ +10% +4 digits. Resistance and Continuity 0.01 Ω ~ 99.9 Ω +2% +2 digits. 100 Ω ~ 99.9 kΩ +5% +2 digits. Open circuit voltage 5 V +1 V. Test current (user selectable) (0 Ω ~ 2 Ω). 205 mA +5 mA. 15 mA +5 mA (user selectable). Loop Test Live to earth/neutral supply 48 V ~ 280 V (45 Hz ~ 65 Hz). Live to live supply 48 V ~ 500 V (45 Hz ~ 65 Hz). L-N/L-L tests +5% +5 digits. L-E tests 0.1 Ω ~ 39.9 Ω +5% +5 digits + noise margin. 40.0 Ω ~ 1000 Ω +10% +5 digits. Display range 0.01 Ω ~ 1000 Ω. Live to earth PFC range 20 kA Live to live PSCC range 20 kA Notes: ? Reference conditions apply. For test environments see service data. RCD Tests Supply up to 100 mA 48 V ~ 480 V (45 Hz ~ 65 Hz). Supply up to 1 A 48 V ~ 280 V. RCD type Type AC, A, S. Type B (pure dc). No trip test (1/2xI) -10% ~ -0%. Trip test (1xI, 2xI and 5xI)+0% ~ +10%. EV 30 mA ac, 6 mA dc (Mode 1 + 2). (Mode 1 + 2) Ramp Test Touch voltage (0 ~ 253 V) +5% +15% +0.5 V. Trip time +1% +1 ms. Trip current +5%. Step Increments VAR (variable RCD selection) 10 mA ~ 50 mA 1 mA steps. 50 mA ~ 500 mA 5 mA steps. 500 mA ~ 1000 mA 10 mA steps. Supply Measurement Voltage 10 V ~ 600 V. (15 ~ 400 Hz) True RMS. +3% + 1 V +2 digits. Phase rotation indication L1-L2-L3 and L1-L3-L2. Frequency 15 Hz ~ 99 Hz +0.5% +1 digit. 100 Hz ~ 400 Hz +2.0% +2 digits. Frequency resolution 0.1 Hz. Power Supply Batteries IEC LR6 type AA alkaline (6 cells - supplied) or 1.2 V NiMH (rechargeable pack of 6 - supplied). Mains charger for on-board re-charging (4 hours typical) 12 V car charger (cigar lighter lead - optional). Earth/ Ground Test Resolution 0.01 Ω. Current 0.45 mA or 4.5 mA. Noise rejection 20 V pk/pk (7 V rms). Max probe resistances Rp and Rc. 100 kΩ @ 50 V. 5 kΩ @ 25 V. 2 and 3 pole method (0.01 Ω ~ 1.999 kΩ). +2.0% +5 digits. ART method (1.00 Ω ~ 1.999 kΩ). +5.0% +5 digits*. Stakeless method (1.00 Ω ~ 199 Ω). +7.0% +5 digits*. Current (via optional clamp meter) +5.0% +3 digits. Range 0.1 mA to 200 A ac. Resolution 0.1 mA. mV Sensor Input Including temperature (third party module) +1.0% +2 digits. Range 0.0 mV to +199.9 mV dc. Resolution 0.1 mV. Data storage Capacity 1000 results. Bluetooth® communication. Safety IEC 61010-1:2010. IEC 61010-30:2010. IEC 61010-031:2008. 600 V CAT III / 300 V CAT IV. (Max Phase to Phase 600 V). IEC 61557:2007 parts 1 to 10. EMC IEC61326 edition 2 location class B. Operating temperature range and humidity -10 °C ~ +55 °C. 90% R.H. at +40 °C max. Storage temperature range and humidity -25 °C ~ +70 °C. Maximum altitude 2000 m. IP rating IP54. Calibration temperature +20 °C. Temperature coefficient <0,1% per °C For test environments see service data. Weight (instrument and case) 1 kg (with batteries, excluding case). Dimensions (instrument and case) 220 mm (H) x 390 mm (W) x 285 mm (D). Megger MFT1741+ warranty Three-years. Megger EVCA210-UK Electric Vehicle Charge-Point Adapter Technical Specifications Input voltage Up to 250 V (single phase system) up to 430 V (three phase system). Input Frequency 50/60 Hz PE Pre-Test Yes - Push button CP Error “E” simulation Push button PP Simulation NC, 13 A, 20 A, 32 A, 63 A CP States A, B, C, D CP Error “E” Yes PE Error (Earth fault) Yes Measuring Ports L1, L2, L3, N and PE Max. 250/430 V, CAT II 300 V, max. 10 A Mains socket Max. 250 V, CAT II 300 V max. 10 A. Note: Do not load mains socket simultaneously with measuring ports! CP Signal Test Ports Approx. +/-12 V, CAT 0 (under normal condition) In case of wrong wiring or error of the charging station these terminals. Measurement category CAT II 300 V Altitude above sea level. 2000 m max Weight Approx: 780g IP-rating IP54 CE directive Low Voltage Directive LVD 2014/35/EU Safety IEC/EN 61010-1:2010 IEC/EN 61010-2-030:2010. Working temperature range 0 ... +40 °C Storage temperature range -10 ... +50 °C Reference humidity range 10 ... 60% relative humidity w/o condensation Working humidity range 10 ... 85% relative humidity w/o condensation

For more information on Megger EV Test Kit 1 talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title