Find The Needle Add My Company
Megger MFT1731-BS Installation Tester
Megger Components Shortage PLEASE NOTE: Megger is currently experiencing a global shortage of components for their popular MFT 1700 Series. We are currently operating a waiting list and as stock becomes available we will ship your order. If you would like to get your hands on these industry-leading MFT's, then we strongly advise that you get in the queue. Shipped as standard in a large soft carrying case, the Megger MFT1731 builds on the capabilities of the MFT1721 by adding support for three-pole ART earth resistance measurements, with a clamp option, and stakeless twin-clamp earth resistance measurements. This model also has internal storage for test results with wireless downloading to smartphones, tablets and other Bluetooth-equipped devices. All of the multifunction installation testers in Megger’s new range incorporate the qualities that have made the previous MFT1700-series instruments so popular and successful. These include a straightforward user interface for fast easy operation, robust construction to withstand the knocks and tumbles of everyday use, comprehensive electrical protection, and an extensive range of safety features, including a CAT IV 300 V/CAT III 600 V safety rating in line with IEC 61010. FEATURES Three-phase installation tester. 2 and 3-wire non-trip loop impedance testing. Fast 2-wire high current loop test including phase to phase testing ability. ZMAX facility. Full range of RCD tests from 10 mA to 1000 mA. Selective, variable type B and 3-phase RCD (no neutral) testing. Auto RCD and ramp. Insulation testing at 1 kV, 500 V, 250 V and 100 V. Continuity and low Ωs at 200 and 15 mA. Adjustable buzzer threshold. True RMS voltage measurement and phase rotation. Supplied in a large soft carry case. Megger MFT1731 Specifications Insulation Tests Output Voltage -0 to +20% at rated load or less. Voltage Display +3% +3 digits +0.5% of rated voltage. Short Circuit Current 1.5 mA nominal test current. Test Current on Load 1 mA at min pass values of insulation. Insulation Accuracy 1000 V 10 kΩ to 999 MΩ (+3% + 2 digits). 500 V 10 kΩ to 500 MΩ (+3% + 2 digits). >500 MΩ (+10% + 4 digits). 250 V 10 kΩ to 250 Ω (+3% + 2 digits). >250 MΩ (+10% + 4 digits). 100 V 10 kΩ to 100 MΩ (+3% + 2 digits). >100 MΩ (+10% + 4 digits). Resistance and Continuity Range and Accuracy 0.01 to 99.9 Ω (+2% + 2 digits). 100 to 99.9 kΩ (+5% + 2 digits). Open Circuit Voltage 5 V + 1 V. Test Current (0 to 2 Ω) 205 mA +5 mA. 15 mA +5 mA (user selectable). Loop Test Live to Earth/Neutral Supply 48 to 280 V (45 to 65 Hz). L-N/L-L Tests +5% +5 digits. L-E Tests 0.1 to 39.9 Ω (+5% +5 digits + noise margin). 40 Ω to 1000 Ω (+10% + 5 digits). Display Range 0.01 to 1000 Ω. Live to Earth PFC Range 20 kA. Live to Live PSCC Range 20 kA. RCD Tests Supply up to 100 mA 48 to 480 V (45 to 65 Hz). Supply up to 1 A 48V to 280 V. RCD Type Type AC, A and S. Type B (Pure DC). No-Trip Test (1/2xI) -10 to -0%. Trip Test (1xI, 2xI and 5xI) +0 to +10%. Ramp Test Touch Voltage (0 to 253 V) +5% +15% +0.5 V. Trip Time +1% +1 ms. Trip Current +5%. Step Increments VAR (Variable RCD Selection) 10 mA to 50 mA 1 mA steps. 50 mA to 500 mA 5 mA steps. 500 mA to 1000 mA 10 mA steps. Supply Measurement Voltage 10 V to 600 V (15 to 400 Hz) True RMS. Voltage Accuracy +3% +1 V +2 digits. Phase Rotation Indication L1-L2-L3 and L1-L3-L2. Frequency 15 Hz to 99 Hz (+0.5% +1 digit). Frequency Resolution 0.1 Hz. Power Supply Batteries 1.2V NiMH Rechargeable Batteries Mains charger for on-board recharging (4 hours typical) 12V optional car charger available. Earth/Ground Test Resolution 0.01 Ω. Current 0.45 mA or 4.5 mA. Noise Rejection 20 V pk/pk (7V rms). Max Probe Resistance (Rp and RC) 100 kΩ @ 50 V. 5 kΩ at 25 V. 2 and 3 Pole Method 0.01 to 1.999 kΩ (+2.0% + 3 digits). ART method (1.00Ω to 1.999 kΩ) with accuracy of +5.0% + 3 digits. Stakeless Method 1.00 to 199 Ω (+7.0% + 3 digits). Current (Via Optional Clamp Meter) Range 0.1 mA to 200 A AC (5.0% + 3 digits). Resolution 0.1 mA. Safety Conformity EC 61010-1: 2010 IEC 61010-30: 2010 IEC 61010-031: 2008 600V CAT III / CAT IV 300V (Max phase to phase 600V) IEC 61557: 2007 parts 1 to 10. EMC IEC61326 edition 2 location class B. Operating Temperature Range and Humidity -10 to +55°C (90% RH at +40°C max). Storage Temperature Range and Humidity -25 to +70°C. Maximum Altitude 2000m. Weight (Instrument and Case) 1 kg (with batteries). Dimensions (Instrument and Case) 150 x 85 x 235 mm (H x W x D). IP Rating IP54. Calibration Temperature +20°C. Temperature Coefficient <0.1% per °C. Megger MFT1731 warranty 1 year extendable to 3 years.

For more information on Megger MFT1731-BS Installation Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title