Find The Needle Add My Company
Megger MIT525 Diagnostic 5kV Insulation Tester
Offering CAT IV, the Megger MIT525 is compact, light 5kV insulation resistance tester for the diagnostic testing and maintenance of high voltage electrical equipment. Enclosed in a tough case it is both smaller and lighter than its predecessor making it even easier to carry and store. As well as measuring insulation resistance to 10 TΩ, the MIT 525 also offers various diagnostic tests such as Polarisation index, Dielectric Absorption Ratio, Step Voltage, Dielectric discharge and ramp testing. The MIT1025 has a full suite of test modes as well as on-board memory and the ability to stream data/download data to a PC/laptop. The Megger MIT525 can be powered from the mains supply or by it’s rechargeable battery, which provides for 4½ to 6 hours of continuous testing with a 100 MΩ load, depending on model. The battery pack contains Lithium-ion cells and should be replaced when it no longer holds a charge. The battery pack is housed within a grey moulded cover secured by four screws. On no account must the transparent inner case be opened. Hazardous voltages up to 10kV will be exposed. FEATURES Measures up to 10 TΩ. Safety rated up to CAT IV 1000 V to 3000 m. Unique dual-case design - additional user protection. Operates from battery or AC mains supply. Rapid charge Li-ion battery. Advanced memory with time/date stamp. MIT515, MIT525 & MIT1025 Intro and Demo Megger MIT525 Specifications Max. output voltage 5 kV. Max. resistance 10 TΩ. Accuracy from 1 MΩ to: +5% ? 1 TΩ +20% to 10 TΩ. Max. noise rejection 3 mA. AC voltage (auto-ranging) 90 - 264 V rms. Test voltages 250 V, 500 V, 1000 V, 2500 V, 5000 V. Resistance range 10 kΩ to 15 TΩ @ 5 kV. Insulation test alarm 100 kΩ to 10 GΩ. Voltmeter range 30 V to 660 V ac or dc, 45Hz - 65Hz. Timer range Up to 99 minutes 59 seconds, 15 second minimum setting. Test modes IR, IR(t), DAR, PI, SV, DD, ramp test. Memory capacity 5.5 hours logging @ 5 sec intervals. Interface USB type B (device). Real time output 1 Hz output readings (V, I, R). Operating temperature range -20 °C to 50 °C. Battery life 6 hours (typical) continuous testing at 5 kV with a 100 MΩ load. Battery charge time 2.5 hours deep discharge, 2 hours normal discharge. IP rating IP65 (lid closed), IP40 (lid open). Dimensions 315 x 285 x 181mm. Weight 4.5kg. Megger MIT525 Warranty 2 year. HV Lead Sets Accessory Order Code HV TEST LEAD SETS (MIT525 only) 5m lead set, large size insulated clips (3 x leads). 1005-259 10 m lead set, large size insulated clips (3 x leads). 1005-260 15 m lead set, large size insulated clips (3 x leads). 1005-261 3 m lead set, medium size insulated clips (3 x leads). 1005-262 10 m lead set, medium size insulated clips (3 x leads). 1005-263 HV TEST LEAD SETS (MIT525 only) 3 x 5 m with large insulated clips. 1002-645 3 x 8 m with large insulated clips. 1002-646 3 x 10 m with large insulated clips. 1002-647 3 x 15 m with large insulated clips. 1002-648 3 x 5 m with medium insulated clips. 1002-641 3 x 8 m with medium insulated clips. 1002-642 3 x 10 m with medium insulated clips. 1002-643 3 x 15 m with medium insulated clips. 1002-644 SCREENED HV TEST LEAD SETS (MIT515, MIT525, MIT1025 only) 3m, 15kV screened, large size insulated clips, supplied in carry holdall. 1005-266 10m, 15kV screened, large size insulated clips, supplied in carry holdall. 1005-267 15m, 15kV screened, large size insulated clips, supplied in carry holdall. 1005-268 20m, 15kV screened, large size insulated clips, supplied in carry holdall. 1005-269

For more information on Megger MIT525 Diagnostic 5kV Insulation Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title