Find The Needle Add My Company
Megger MOM2 with 5m Kelvin Clamps
The Megger MOM2 is designed to measure the resistance of circuit breaker contacts, bus-bar joints and other high-current links. The Megger MOM2 is designed with safety, ease of use and versatility in mind. The MOM2 200A ductor uses an ultra capacitor to generate the high output current. The ultra capacitor is able to store a huge amount of energy compared to conventional capacitors and can deliver very high current during the discharge thanks to its very low internal resistance. The microhmmeter can be used anywhere to measure a low resistance value with high accuracy. FEATURES Breaker contact testing according to IEC and IEEE. Up to 220 A (Initial current). Battery powered (rechargable). Up to 2200 measurements per charge. Safe test - DualGround. Reliable data log: data is stored with real time clock time stamp. Pass / Fail function. BluethoothPC communication (data transfer). Display backlight. High contrast LCD display. All weather, all environment, all industry usage. Megger MOM2 Product Video Megger MOM2 Specifications Specifications are valid at fully charged batteries and an ambient temperature of +25°C. Measurement Specs Minimum Current Guarantee Selectable 50 A/100 A Valid at resistance ?2 mΩ. PASS/FAIL Settable from 1 µΩ to 1999 mΩ. Number of Measurements on Fully Charged Batteries Typical 2200 at I min = 50 A and 0.1s Typical 800 at I min = 100 A and 0.1s. Interference Supression Range 0 to 1000 mΩ. Resolution 0 to 999 µΩ: 1 µΩ 1.0 to 9.99 mΩ: 0.01 mΩ 10.0 to 99.9 mΩ: 0.1 mΩ 100 to 1000 mΩ: 1 mΩ. Inaccuracy 0 to 1999 µΩ: +1% of reading + 1 digit 2 to 500 mΩ: +2% of reading + 1 digit 500 to 1000 mΩ: +4% of reading + 1 digit. Outputs Range >100 A DC (R < 2 mΩ). Output Voltage (max) 2.5 V DC. Generation Duration Selectable: 0.1s, 0.6s, 3s. Generation Time 0.1s Max: 10s, Typical: 8s. 0.6s Max: 20s, Typical: 16s. 3s Max: 130s, Typical: 100s. Inputs Sense (+/-) Connector: 4 mm banana jack Voltage: +3 V DC. Trigger Input Threshold 8 V DC. DC IN 12 to 24 V DC, 2 A max. Logger Data Label, Timestamp, I max, i min, I limit, Resistance, Meas. Time, P/F Limit. Labelling Schemes Circuit breaker oriented or running numbers. Capacity 104 measurements. Environmental Specifications Application Field For use in high voltage substations and industrial environments. Operating Temperature -20 to +50°C (-4 to +122°F). Storage Temperature -40 to +70°C (-40 to +158°F). Relative Humidity (%RH) 5 to 95%, non-condensing. Pollution Degree 2. Shock IEC 60068-2-27. Vibration IEC 60669-2-6. Transport ISTA 2A. CE Marking EMC - 2004/108/EC. LVD - 2006/95/EC. General Specs Battery Power Five AA (HR6) 2700 mAh NiMH cells. Recharge Time <12h. Typical Recharge Time at 25°C 3h. Battery Charger Mains Voltage 100 to 250 V AC, 50/60 Hz. Battery Charger Power Consumption 60 W. Battery Charger Protection Against wrong battery type, low/high temperature. Real Time Clock Battery Life ? 10 years. Audible Feedback Different buzzer sounds User Presets 3. Field Calibration Encapsulation IP54. Dimensions (excluding binding posts) 217 x 104 x 72 mm (8.5 x 4.1 x 2.8 inches). Weight 1.0 kg (2.2 lbs) instrument only 5.0 kg (11 lbs) with accessories and carrying case. Megger MOM2 warranty 1 year.

For more information on Megger MOM2 with 5m Kelvin Clamps talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title