Sign In
The Megger PAT320 is the PAT tester if you need high productivity with a tough and easy to use instrument. If you are moving into PAT testing for the first time or you don’t want the complexity of database management, PAT320 is ideal for you.
Push-button operation makes the PAT320s fast and intuitive to use. All test requirements are supported. For Class I and Class II, IEC power leads, extension leads and full tests for portable RCDs. Automatic testing proceeds sequentially through bond, insulation and operational tests, indicating a pass or fail at each test. Should a fail occur, testing is stopped.
Business in a box is ideal for any competent person or business wishing to diversify into a new market, to generate an additional income stream or simply start-out in portable appliance testing. For an electrical contractor this could be a tool to improve customer service by developing a wider portfolio of capabilities.
When manual testing, each test is preceded by a selection screen where the test parameters can be chosen. These diagnostic buttons provide direct access to any test individually, allowing single tests to be performed following repair or a suspect result.
FEATURES
Simple manual or automatic testing.
230V and 110V operation.
Virtual continuous operation.
Bond testing at 25 A,10 A and 200 mA.
Full colour display.
Tests portable RCDs and extension leads.
Differential, touch and substitute leakage testing.
WHAT'S INCLUDED
Megger PAT320 PAT Tester.
How To Test Portable Appliances Booklet.
How To Market Your Business Guide on CD.
Protective Case.
PAT Report Certificate Book (50 x Certificates).
Laptop Supply Adaptor.
Combined Earth Bond, Continuity and Insulation Test Lead with Probe and Crocodile Clip.
13A Extension Lead Adaptor.
1000 x Passed Labels.
Lead Storage Pouch.
Full User Guide on CD.
Laminated Quick Start Guide.
Megger Business In A Box Video
Megger PAT320 Specifications
Electrical Supply Range
230 V AC
230 V AC +10%.
110 V AC
110 V AC +10%.
Supply Measurement
Voltage
+2% + 1 V.
Frequency
+1% + 0.1 Hz.
Bond Test
Open Circuit Voltage
9 V AC +10% +0.1 V (Supply: 230 V 50 Hz).
10 A Bond Test Current
10 A rms +20% +0.5 A into 0.1 Ω.
25 A Bond Test Current
25 A rms + 5% + 0.5 A into 0.1 Ω.
Earth Bond Resistance Accuracy
+5% + 3 digits (0 to 0.49 Ω)
+5% + 5 digits (0.5 to .99 Ω).
Earth Bond Resistance Resolution
10 mΩ (0 to 1.99 Ω).
Display Range
0 to 1.99 Ω.
Bond Test Nulling
Up to 1.00 Ω.
Adjustable Test Duration
User selectable from 1 sec to 20 sec.
Continuity Test
Continuity Test Voltage
4.0 V DC -0% +10% (open circuit).
Continuity Test Current
200 mA -0% + 10% + 5 mA (into 2 Ω load).
Continuity Resistance Accuracy
+5% +3 digits (0 to 0.49 Ω)
+5% +5 digits (0.5 to .99 Ω).
Continuity Resistance Resolution
10mΩ (1 to 19.99 Ω).
Display Range
0 to 19.99 Ω.
Continuity Test Nulling
Up to 9.99 Ω.
Test Duration
User selectable from 1 sec to 20 sec.
Note: The continuity test is a DC test performed automatically in both positive and negative directions. The average of the two results is shown.
Insulation Test
Insulation Test Voltage
250 V DC -0%/+25% open circuit
500 V DC -0%/+25% open circuit
(500 V DC across 0.5 MΩ).
Insulation Resistance Accuracy (230 V)
+2% +5 digits (0 to 19.99 MΩ)
+5% + 10 digits (20 to 99.99 MΩ).
Insulation Resistance Accuracy (110 V)
+5 +5 digits (0 to 10 MΩ).
Insulation Resistance Resolution
0.01 MΩ (0.10 to 99.99 MΩ).
Display Range
0 to 99.99M Ω.
Test Duration
User selectable from 1 sec to 1 minutes.
Substitute Leakage Test
Test Voltage
40 V AC +10%.
Test Frequency
Nominal mains 50/60 Hz.
Leakage Current Accuracy
+5% + 5 digits.
Leakage Current Resolution
0.01 mA.
Display Range
0 to 19.99 mA.
Test Duration
User selectable from 1 sec to 1 minute
Reading corrected to 230 V + 10% or 110 V +10% AC.
Differential Leakage Current
Test Voltage
Nominal mains 110 V/230 V AC.
Test Frequency
Nominal mains 50/60 Hz.
Differential Leakage Current Accuracy
+5% + 5 digits.
Differential Leakage Current Resolution
0.01 mA.
Display Range
0 to 19.99 mA
Reading corrected to 230 V +10 % or 110 V + 10% AC.
Touch Current Test
Test Voltage
Nominal mains 115 V/230 V AC.
Test Frequency
Nominal mains 50/60 Hz.
Touch Current Accuracy
+5% +5 digits.
Touch Current Resolution
0.01 mA.
Display Range
0 to 10 mA.
Test Duration
User selectable from 1 sec to 5 sec
Reading corrected to 230 V + 10% or 110 V + 10% AC.
Operational Test
Test Voltage
Nominal mains 110 V/230 V AC.
Accuracy
+5% +10 digits (0 to 99 VA)
+5% +50 digits (100 to 999 VA)
+5% +100 digits (1000 to 3700 VA).
Resolution
1 VA (0 to 3700 VA).
Display Range
0 to 3.99 KVA
Reading corrected to 230 V or 110 V AC
Results show load VA.
Extension Lead Test
Polartity Test Voltage
12 V
Polarity
Leak OK
Live neutral S/C
Live neutral reversed
Live/neutral O/C.
Portable RCD Test
RCD Test Voltage
Nominal mains 110/230V.
RCD Test Frequency
50Hz.
Test Current Accuracy
-8% to -2% (1/2 x I)
+2% to +8^ (1 x 1,5 x I).
Trip Time Accuracy
+1% +5 digits.
Trip Time Resolution
0.1ms.
Display Range
0 to 1999ms (1/2 x I)
0 to 300ms (1 x I)
0 to 40ms (5 x I).
Fuse Test
Test Voltage
3.3V.
Warning
Audible Beep if fuse is ok.
Dimensions (with case)
190 (H) x 400 (D) x 290mm (W).
Weight (instrument only)
4.9 kg.
Megger PAT320 BIAB warranty
1 year.
For more information on Megger PAT320 Business in a Box talk to Cuthbertson Laird Group
Enquire Now
List your company on FindTheNeedle.