Megger PAT350 with Flash
Simple push-button operation makes the Megger PAT350 fast and intuitive in use. All regulatory test requirements are supported, including Class I and Class II; IEC power leads; extension leads and full tests for portable RCDs. An automatic mode is available for Class I and Class II testing. With the addition of a Flash test, this easily portable desktop appliance tester is designed for the hire industry and users who require a complete range of functions to allow automatic or manual testing of the widest range of electrical assets. FEATURES Simple manual or automatic testing. 230V and 110V operation. Virtual continuous operation. Bond testing at 25 A,10 A and 200 mA. Full colour display. Tests portable RCDs and extension leads. Differential, touch and substitute leakage testing. PAT320 & PAT350 Product Demo Megger PAT350 Specifications Electrical Supply Range 230 V AC 230 V AC +10%. 110 V AC 110 V AC +10%. Supply Measurement Voltage +2% + 1 V. Frequency +1% + 0.1 Hz. Bond Test Open Circuit Voltage 9 V AC +10% +0.1 V (Supply: 230 V 50 Hz). 10 A Bond Test Current 10 A rms +20% +0.5 A into 0.1 Ω. 25 A Bond Test Current 25 A rms + 5% + 0.5 A into 0.1 Ω. Earth Bond Resistance Accuracy +5% + 3 digits (0 to 0.49 Ω) +5% + 5 digits (0.5 to .99 Ω). Earth Bond Resistance Resolution 10m Ω (0 to 1.99 Ω). Display Range 0 to 1.99 Ω. Bond Test Nulling Up to 1.00 Ω. Adjustable Test Duration User selectable from 1 sec to 20 sec. Continuity Test Continuity Test Voltage 4.0 V DC -0% +10% (open circuit). Continuity Test Current 200 mA -0% + 10% + 5 mA (into 2 Ω load). Continuity Resistance Accuracy +5% +3 digits (0 to 0.49 Ω) +5% +5 digits (0.5 to .99 Ω). Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω). Display Range 0 to 19.99 Ω. Continuity Test Nulling Up to 9.99 Ω. Test Duration User selectable from 1 sec to 20 sec. Note: The continuity test is a DC test performed automatically in both positive and negative directions. The average of the two results is shown. Insulation Test Insulation Test Voltage 250 V DC -0%/+25% open circuit 500 V DC -0%/+25% open circuit (500 V DC across 0.5 MΩ). Insulation Resistance Accuracy (230 V) +2% +5 digits (0 to 19.99 MΩ) +5% + 10 digits (20 to 99.99 MΩ). Insulation Resistance Accuracy (110 V) +5 +5 digits (0 to 10 MΩ). Insulation Resistance Resolution 0.01 MΩ (0.10 to 99.99 MΩ). Display Range 0 to 99.99 MΩ. Test Duration User selectable from 1 sec to 1 minutes. Substitute Leakage Test Test Voltage 40 V AC +10%. Test Frequency Nominal mains 50/60 Hz. Leakage Current Accuracy +5% + 5 digits. Leakage Current Resolution 0.01 mA. Display Range 0 to 19.99 mA. Test Duration User selectable from 1 sec to 1 minute Reading corrected to 230 V + 10% or 110 V +10% AC. Differential Leakage Current Test Voltage Nominal mains 110 V/230 V AC. Test Frequency Nominal mains 50/60 Hz. Differential Leakage Current Accuracy +5% + 5 digits. Differential Leakage Current Resolution 0.01 mA. Display Range 0 to 19.99 mA Reading corrected to 230 V +10 % or 110 V + 10% AC. Touch Current Test Test Voltage Nominal mains 115 V/230 V AC. Test Frequency Nominal mains 50/60 Hz. Touch Current Accuracy +5% +5 digits. Touch Current Resolution 0.01 mA. Display Range 0 to 10 mA. Test Duration User selectable from 1 sec to 5 sec Reading corrected to 230 V + 10% or 110 V + 10% AC. Operational Test Test Voltage Nominal mains 110 V/230 V AC. Accuracy +5% +10 digits (0 to 99 VA) +5% +50 digits (100 to 999 VA) +5% +100 digits (1000 to 3700 VA). Resolution 1 VA (0 to 3700 VA). Display Range 0 to 3.99 KVA Reading corrected to 230 V or 110 V AC Results show load VA. Extension Lead Test Polarity Test Voltage 12 V. Polarity Leak OK Live neutral S/C Live neutral reversed Live/neutral O/C. Flash Test Flash Test Voltage 1500 V AC nominal for class 1 3000 V AC nominal for class 2. Flash Test Current <3.5 mA short circuit @ 253 V primary supply voltage. Flash Test Breakdown Current Accuracy +5% + 5 digits Flash Test Breakdown Current Resolution 0.01 mA. Display Range 0 to 3.0 mA. Test Duration User-controlled. Portable RCD Test RCD Test Voltage Nominal mains 110/230 V. RCD Test Frequency 50 Hz. Test Current Accuracy -8% to -2% (1/2 x I) +2% to +8% (1 x 1,5 x I). Trip Time Accuracy +1% +5 digits. Trip Time Resolution 0.1 ms. Display Range 0 to 1999 ms (1/2 x I) 0 to 300 ms (1 x I) 0 to 40 ms (5 x I). Fuse Test Test Voltage 3.3 V. Warning Audible Beep if fuse is ok. General Operating temperature 10 to +50 deg C. Storage Temperature -20 to +60 deg C. Dimensions (instrument only) 175 mm (H) x 320 mm (D) x 250 mm (W). Weight (instrument only) 5.0 kg. Megger PAT350 warranty 1 year.

For more information on Megger PAT350 with Flash talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title