Find The Needle Add My Company
Megger PAT410 Manual PAT Tester with Download
The Megger PAT410 pat tester provides a low-profile 230V only solution without the added weight required of 110 V operation, plus a database capacity for up to 10,000 test results. Featuring an earth bond test at 200mA (IT safe), along with a full range of 240V PAT tests, the Megger PAT410 features robust design, combined with reliability. The large 5.7" colour LCD display allows for a clear, menu driven test process. The full QWERTY keypad on the Megger PAT 410 ensures asset data and descriptions can be easily added, and that test settings can be manually adjusted. FEATURES Vast on-board memory to keep you the job longer. Continuous operation, no need to stop and wait for the tester to cool down. Instant re-start as you move from room to room testing. Soft keys to speed you through the testing process. Full PAT testing including RCD testing. Most productive tester in its class. Megger PAT400 Series Product Video Megger PAT410 Specifications Electrical Supply Range PAT410, PAT420, PAT450 230 V +10 @ 50/60 Hz. PAT420, PAT450 110 V + 10% + 110 V +10% @50Hz. Bond Test (10A and 25A) Not PAT410 Open Circuit Voltage 9 V AC +10% + 0.1 V (supply: 230 V 50 Hz). Earth Bond Resistance Accuracy +5% + 3 digits (0 to 0.49 Ω) +5% +5 (0.5 to 0.99 Ω). Display Range 0 to 1.99 Ω. Continuity Test (200mA) Continuity Test Voltage 9 V AC + 10% + 0.1 V (supply: 230 V 50 Hz). Continuity Resistance Accuracy +5% + 3 digits (0 to 0.49 Ω) +5% + 5 digits (0.5 to 0.99 Ω). Continuity Resistance Resolution 10 mΩ (1 to 19.99 Ω). Display Range 0 to 19.99 Ω. Insulation Test (250V and 500V) Insulation Resistance Accuracy (230 V) +2% + 5 digits (0 to 19.9 MΩ) +5% + 10 digits (20 to 99.99 MΩ). Insulation Resistance Resolution 0.01 MΩ. Display Range 0 to 99.99 MΩ. Substitute Leakage Test Test Voltage and Frequency 40 V AC +10% nominal mains frequency. Leakage Current Accuracy +5% + 5 digits. Leakage Current Resolution 0.01 mA. Display Range 0 to 19.99 mA. Differential Leakage Current Test Voltage Nominal mains 110/230 V AC. Test Frequency Nominal mains 50/60 Hz. Differential Leakage Current Accuracy +5% + 0.05 mA (1.0 mA to 9.99 mA) +5% + 0.1 mA (0.1 mA to 0.99 mA). Resolution 0.01 mA. Display/Measurement Range 0.10 mA to 19.99 mA. Touch Current Test Test Voltage and Frequency Nominal mains supply. Touch Current Accuracy +5% + 5 digits. Touch Current Resolution 0.01 mA. Display 0 to 10 mA. Operational Test Test Voltage and Frequency Nominal mains supply. VA Rating 230 V 3700 VA 110 V 1800 VA. VA Accuracy +5% + 10 digits (0 to 99 VA) +5% + 50 digits (100 VA to 999 VA) +5% + 100 digits (1000 VA to 3700 VA). Resolution 1 VA (0 to 3700 VA). Display Range 0 to 3990 VA. Extension Lead Test Tests Performed Bond, insulation and polarity. Polarity Test Voltage 12 V. Polarity checks Lead ok Live neutral S/C Live neutral reversed Live/neutral O/C. Flash Test (PAT450 only) Flash Test Voltage 1500 V AC nominal for class 1 3000 V AC nominal for class 2. Flash Test Current <3.5 mA short circuit @ 253 V primary supply voltage. Flash Test Breakdown Current Accuracy +5% +5 digits. Flash Test Breakdown Current Resolution 0.01 mA. Display Range 0 to 3.0 mA. Portable RCD Test Test Voltage and Frequency Nominal mains supply. Test Current Accuracy -8% to -2% (1/2 x I) +2 to +8% (1 x I, 5 x I). Trip Time Accuracy +1% + 5 digits. Trip Time Resolution 0.1 ms. Display Range 0 to 1999 ms (1/2 x I) 0 to 300 ms (1 x I) 0 to 40 ms (5 x I). Fuse Test Test Voltage 3.3 V. Warning Audible beep if fuse is OK. Environmental Operating Temperature -10 to 50°C. Storage Temperature -20 to 60°C. Humidity 90% RH @ -10 to 30°C 75% RH @ +30 to 50°C. Maximum Altitude 2000m. Ingress Protection IP40. General Weight 4.4 kg. Dimensions 180 (H) x 255 (W) x 320 mm (L). Safety IEC 61010-1: CAT II 300 V. EMC IEC 61326-1: 2006 IEC 61326-2-2: 2005. Megger PAT410 warranty One-year.

For more information on Megger PAT410 Manual PAT Tester with Download talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title