Find The Needle Add My Company
Megger RCDT330 RCD Tester
The Megger RCDT330 covers a wider supply voltage range of 50V to 290V than the RCDT310, allowing use with centre-tapped 110V supplies. It incorporates ramp testing testing, for RCD tripping current measurement, and the unique Megger auto sequence test feature, which saves time by allowing the tester to conduct all the RCD tests, and to store the results while the operator stands by the RCD, resetting it as appropriate. The operating current range of the RCDT330 covers 10mA to 1,000mA devices, and the ability to measure AC supply voltage and frequency. The large liquid crystal display for test results is backlit in this model, making it easier to use in locations with low ambient light levels. Data is stored in non-volatile memory, being retained when the instrument is switched off or batteries are exhausted. FEATURES Tests standard, DC and selective RCDs. Ramp testing. Auto (Remote) testing. 3 Phase safe. Enables testing on 110 V centre tapped supplies. Tough rubber armoured case with built-in cover. Weatherproof to IP54. Megger RCDT330 Specifications RCD Test Ranges (to EN61557-6) Supply Voltage RCDT310: 100 V to 280 V (45 Hz to 65 Hz) RCDT320: 50 V to 280 V (45 Hz to 65 Hz) RCDT330: 50 V to 280 V (45 Hz to 65 Hz) Minimum voltage 71 V for 300 mA RCDs, 100 V for 500 mA RCDs and 205 V for 1000 mA RCDs. Test Current Accuracy No Trip Test (1/2I): -8 to -2%. Trip Test (I, 5I): +2% to +8%. Trip Time +1% + 1 ms. Voltage Measurement AC Range 0 to 300 V (25 to 450 Hz). Accuracy +2% + 2 digits. Frequency Measurements (RCDT320/330 Only) Range 25 to 450 Hz. Accuracy 25 to 199.9 Hz + 0.1 Hz 200 Hz to 450 Hz + 1 Hz. Fault (Touch) Voltage Displayed Range 0 to 50 V. Error +5%/+15% + 0.5 V. Programmable RCD Step Increments 10 mA to 50 mA 1 mA steps. 50 mA to 500 mA 5 mA steps. 500 mA to 1000 mA 10 mA steps. Test Result Storage (1000 Results) - RCDT330 Only Job Number 256 locations. Distribution Board Number 99 locations. Circuits 99 locations. Phases P1, P2, P3. Temperature and Humidity Operating Range -5 to 40°C. Operating Humidity 93% RH at +40°C max. Storage Range -25 to 70°C. Maximum Altitude 2000m. Environmental Protection IP54. Safety Rating IEC 61010-1 CAT III 300 V phase to earth. Power Supply Batteries 8 x 1.5 V cells IEC LR6 type (AA alkaline). Rechargeable 8 x 1.2 V NiCd or NiMH cells. Battery Life 2000 consecutive tests. General Specs Weight 980g. Dimensions 203 x 148 x 78 mm. E.M.C In accordance with IEC61326-1. Megger RCDT330 warranty Three-years.

For more information on Megger RCDT330 RCD Tester talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title