Please Note: The Sverker780 Basic is not supplied with the test lead set and transport case.
With its ease of configuration and its comprehensive range of facilities, including a variable-frequency voltage source with a continuous phase-shift function, Megger's self-contained Sverker 780 relay test set is an invaluable 'toolbox' for protection engineers, which is capable of testing almost any type of single-phase protection relay conveniently and efficiently.
You can also test directional protective equipment efficiantly by means of the built-in variable voltage source. In Megger SVERKER780 this has a continuous phase shift function and adjustable frequency as well. Automatic reclosing devices can also be tested - just as easily.
Designed to comply with EU standards and other personal and operational safety standards, the SVERKER780 is also equipped with a serial port for communication with personal computers and the PC software SVERKER Win.
Sverker780 Extra Features:
Plotting excitation curves.
Current and voltage transformer ratio tests.
Burden measurement for protective relay test equipment.
Impedance measurement.
Efficiency tests.
Polarity (direction) tests.
Injection: Maintained, Momentary & Max. time.
Filtering: When filtering is selected, five successive readings are averaged.
Off delay: The turning off of generation can be delayed after tripping.
Megger Sverker780 Specifications
Current Outputs - AC
Range
No-Load voltage (min)
Full-Load Voltage (min)
Full-Load Current (max)
Load/Unload Times On (max) / Off (min)
0-10 A
90 V
75 V
10 A
2/ 15 minutes
0-40 A
25 V
20 V
40 A
1/ 15 minutes
0-100 A
10 V
8 V
100 A
1/ 15 minutes
0-100 A
10 V
-
250 A*
200 A**
1 sec/ 5 minutes
* Mains voltage 230 V AC
** Mains voltage 115 V AC
Voltage Outputs - AC/DC
Range
No-Load Voltage (min)
Full-Load Voltage (min)
Full-Load Current (max)
Load/Unload Times On (max) / Off (min)
0-250 V AC
290 V AC
250 V AC
3 A
10 min/ 45 min
0-300 V DC
320 V DC
250 V DC
2 A
10 min / 45 min
Separate AC Voltage Source (SVERKER 780)
Range
No-Load Voltage (min)
Full-Load Voltage (min)
Full-Load Power (max)
5-220 V AC, minimim step 0.1 V
240 V AC
220 V AC at 33 W
200 V AC at 46 W
33 W continuously.
46 W 1 minute
Phase Angle
0 to 359°.
Resolution
1°.
Inaccuracy
+2°.
Frequency
15 to 550 Hz.
Resolution
1 mHz.
Inaccuracy
+0.1%.
Auxiliary DC Output
Range
Voltage
Max Current
20 to 130 V
20 V
130 V DC
300 mA
375 mA
130 to 220 V DC
130 V
220 V DC
325 mA
400 mA
Environment
Application Field
This instrument is intended for use in HV substations and industrial environments.
Operating Temperature
0 to +50°C (32 to +122°F).
Storage/Transport Temperature
-40 to +70°C (-40 to +158°F).
Humidity
5 to 95% RH non-condensing.
CE-Marking
LVD
Low voltage directive 2006/95/EC.
EMC
EMC directive 2004/108/EC.
General Specifications
Mains Voltage
115/230 V AC, 50/60 Hz.
Power Consumption (Max)
1380 W.
Protection
Thermal Cutouts, automatic overload protection.
Display
LCD.
Languages
Bulgarian, Czech, English, French, German, Russian, Spanish, Swedish and Turkish.
Dimensions (Instrument)
250 x 270 x 220 mm (13.8 x 10.6 x 8.7").
Dimensions (Transport Case)
610 x 350 x 275 mm (24.0 x 13.8 x 10.8").
Weight
17.6 kg (38.1lbs)
26.3 kg (58lbs) with accessories + case.
Sverker 780 warranty
1 year.
Ammeter
Measurement Method
AC, true RMS
DC, mean value.
Ranges
Internal
0.00 to 250.0 A.
External
0.000 to 6.000 A.
Inaccuracy (Internal Range)
0-10 A AC
+(1% + 20 mA).
0-40 A AC
+(1% + 40 mA).
0-100 A AC
+(1% + 200 mA).
Inaccuracy (External Range)
0-0.6 A AC
+(1% + 20 mA).
0-6 A AC
+(1% + 20 mA).
0-0.6 A DC
+(0.5% + 2 mA).
0-6 A DC
+(0.5% + 20 mA).
Resolution
Internal Range
10 mA (range <100 A)
100 mA (range >100 A).
External Range
1 mA.
Voltmeter
Measurement Method
AC, true RMS.
Range
0.00 to 600.0 V.
Inaccuracy
AC, +(1% + 200 mV) Max value
DC +(0.5% + 200 mV) Max value
Values are range dependant.
Power Factor and Phase Angle Measurements
Range
Resolution
Inaccuracy
Power Factor cos ?
-0.99 (cap) to +0.99 (ind)
0.01
+0.04
Phase Angle cos ? (°)
000 - 359°
1°
+2°
Impedance/Power Measurements
AC
Z (Ω and °), Z (Ω), R and X (Ω and Ω), P (W), S (VA), Q (VAR).
DC
R (Ω), P (W).
Range
Up to 999 kΩ (X=unit).
Make/Break Contact
Max Current
1 A.
Max Voltage
250 V AC or 120 V DC.
Reclosing Test
Items Measured
Tripping and reclosing times.
Display
After test is finished a list of all times appears in the display.
Break State Feedback
The make/break contact can be used to feed back the breaker state.
Max Number of Reclosings
49.
Max Testing Time
999s.