Find The Needle Add My Company
Megger Sverker 780 Basic
Please Note: The Sverker780 Basic is not supplied with the test lead set and transport case. With its ease of configuration and its comprehensive range of facilities, including a variable-frequency voltage source with a continuous phase-shift function, Megger's self-contained Sverker 780 relay test set is an invaluable 'toolbox' for protection engineers, which is capable of testing almost any type of single-phase protection relay conveniently and efficiently. You can also test directional protective equipment efficiantly by means of the built-in variable voltage source. In Megger SVERKER780 this has a continuous phase shift function and adjustable frequency as well. Automatic reclosing devices can also be tested - just as easily. Designed to comply with EU standards and other personal and operational safety standards, the SVERKER780 is also equipped with a serial port for communication with personal computers and the PC software SVERKER Win. Sverker780 Extra Features: Plotting excitation curves. Current and voltage transformer ratio tests. Burden measurement for protective relay test equipment. Impedance measurement. Efficiency tests. Polarity (direction) tests. Injection: Maintained, Momentary & Max. time. Filtering: When filtering is selected, five successive readings are averaged. Off delay: The turning off of generation can be delayed after tripping. Megger Sverker780 Specifications Current Outputs - AC Range No-Load voltage (min) Full-Load Voltage (min) Full-Load Current (max) Load/Unload Times On (max) / Off (min) 0-10 A 90 V 75 V 10 A 2/ 15 minutes 0-40 A 25 V 20 V 40 A 1/ 15 minutes 0-100 A 10 V 8 V 100 A 1/ 15 minutes 0-100 A 10 V - 250 A* 200 A** 1 sec/ 5 minutes * Mains voltage 230 V AC ** Mains voltage 115 V AC Voltage Outputs - AC/DC Range No-Load Voltage (min) Full-Load Voltage (min) Full-Load Current (max) Load/Unload Times On (max) / Off (min) 0-250 V AC 290 V AC 250 V AC 3 A 10 min/ 45 min 0-300 V DC 320 V DC 250 V DC 2 A 10 min / 45 min Separate AC Voltage Source (SVERKER 780) Range No-Load Voltage (min) Full-Load Voltage (min) Full-Load Power (max) 5-220 V AC, minimim step 0.1 V 240 V AC 220 V AC at 33 W 200 V AC at 46 W 33 W continuously. 46 W 1 minute Phase Angle 0 to 359°. Resolution 1°. Inaccuracy +2°. Frequency 15 to 550 Hz. Resolution 1 mHz. Inaccuracy +0.1%. Auxiliary DC Output Range Voltage Max Current 20 to 130 V 20 V 130 V DC 300 mA 375 mA 130 to 220 V DC 130 V 220 V DC 325 mA 400 mA Environment Application Field This instrument is intended for use in HV substations and industrial environments. Operating Temperature 0 to +50°C (32 to +122°F). Storage/Transport Temperature -40 to +70°C (-40 to +158°F). Humidity 5 to 95% RH non-condensing. CE-Marking LVD Low voltage directive 2006/95/EC. EMC EMC directive 2004/108/EC. General Specifications Mains Voltage 115/230 V AC, 50/60 Hz. Power Consumption (Max) 1380 W. Protection Thermal Cutouts, automatic overload protection. Display LCD. Languages Bulgarian, Czech, English, French, German, Russian, Spanish, Swedish and Turkish. Dimensions (Instrument) 250 x 270 x 220 mm (13.8 x 10.6 x 8.7"). Dimensions (Transport Case) 610 x 350 x 275 mm (24.0 x 13.8 x 10.8"). Weight 17.6 kg (38.1lbs) 26.3 kg (58lbs) with accessories + case. Sverker 780 warranty 1 year. Ammeter Measurement Method AC, true RMS DC, mean value. Ranges Internal 0.00 to 250.0 A. External 0.000 to 6.000 A. Inaccuracy (Internal Range) 0-10 A AC +(1% + 20 mA). 0-40 A AC +(1% + 40 mA). 0-100 A AC +(1% + 200 mA). Inaccuracy (External Range) 0-0.6 A AC +(1% + 20 mA). 0-6 A AC +(1% + 20 mA). 0-0.6 A DC +(0.5% + 2 mA). 0-6 A DC +(0.5% + 20 mA). Resolution Internal Range 10 mA (range <100 A) 100 mA (range >100 A). External Range 1 mA. Voltmeter Measurement Method AC, true RMS. Range 0.00 to 600.0 V. Inaccuracy AC, +(1% + 200 mV) Max value DC +(0.5% + 200 mV) Max value Values are range dependant. Power Factor and Phase Angle Measurements Range Resolution Inaccuracy Power Factor cos ? -0.99 (cap) to +0.99 (ind) 0.01 +0.04 Phase Angle cos ? (°) 000 - 359° 1° +2° Impedance/Power Measurements AC Z (Ω and °), Z (Ω), R and X (Ω and Ω), P (W), S (VA), Q (VAR). DC R (Ω), P (W). Range Up to 999 kΩ (X=unit). Make/Break Contact Max Current 1 A. Max Voltage 250 V AC or 120 V DC. Reclosing Test Items Measured Tripping and reclosing times. Display After test is finished a list of all times appears in the display. Break State Feedback The make/break contact can be used to feed back the breaker state. Max Number of Reclosings 49. Max Testing Time 999s.

For more information on Megger Sverker 780 Basic talk to Cuthbertson Laird Group

Enquire Now

  Please wait...

Location for : Listing Title